11968.1 |
0.040" Bertha Aluminum Storm Panel (2.25" Deep)- Non-HVHZ - Drawing Number 17-094 |
Corrugated aluminum storm panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 12'-0" for +25, -25 p.s.f. and 4'-0" for +125, -130 p.s.f. for sections 1, 3, 4, 6, 7, 8, 8A, 9 and 11. See sheet 10 of installation drawing for other spans and pressures. Valid only for wind zones 1,2 & 3 as defined by ASTM E-1996. |
Installation Instructions FL11968_R4_II_EASTERN METAL SUPPLY2c INC._DRAWING 17-094_0.040 BERTHA ALUMINUM STORM PANEL.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R4_AE_EASTERN METAL SUPPLY2c INC._DRAWING 17-094_PRODUCT EVALUATION REPORT.pdf Created by Independent Third Party: Yes |
|
11968.2 |
0.050" Bertha Aluminum Storm Panel (2.25" Deep)- Non-HVHZ - Drawing Number 17-096 |
Corrugated aluminum storm panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 12'-11" for +30, -30 p.s.f. and 8'-2" for +75, -80 p.s.f. for mountings without "h" header. See sheet 5 of installation drawing for other spans and pressures. Valid only for wind zones 1,2 & 3 as defined by ASTM E-1996. |
Installation Instructions FL11968_R4_II_EASTERN METAL SUPPLY, INC._DRAWING 17-096_ 0.050 BERTHA ALUMINUM STORN PANEL.PDF Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R4_AE_EASTERN METAL SUPPLY, INC._ DRAWING 17-096_PRODUCT OF EVALUATION REPORT.PDF Created by Independent Third Party: Yes |
|
11968.3 |
24 Gage Galvanized Bertha Steel Storm Panel (2.25" Deep)- Non-HVHZ - Drawing Number 17-095 |
corrugated galvanized steel storm panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 9'-8" for +30, -40 p.s.f. and 7'-2" for +70, -80 p.s.f. for panels mounted without "H" header. See sheet 4 of installation drawing for other spans and pressures.Valid only for wind zones 1,2 & 3 as defined by ASTM E-1996. |
Installation Instructions FL11968_R4_II_EASTERN METAL SUPPLY, INC._DRAWING 17-095_24 GAGE GALVANIZE BERTHA STEEL STORM PANEL.PDF Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R4_AE_EASTERN METAL SUPPLY, INC._DRAWING 17-095_PRODUCT EVALUATION REPORT.PDF Created by Independent Third Party: Yes |
|
11968.4 |
Clear Bertha Storm Panels (2 1/4") - Drawing Number 17-098 |
corrugated polycarbonate storm panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max/ span is 10'-0" for +28, -28 p.s.f. A.S.D. and 4'-0" for +105, -110 p.s.f. A.S.D desgin load. See sheet 3 of installation drawings for other spans and pressures. Valid only for wind zones 1,2 & 3 as defined by ASTM E-1996. |
Installation Instructions FL11968_R4_II_EASTERN METAL SUPPLY, INC._DRAWING 17-098_CLEAR BERTHA STORM PANEL 2.25.PDF Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R4_AE_EASTERN METAL SUPPLY, INC._DRAWING 17-098_ PRODUCT OF EVALUATION REPORT.PDF Created by Independent Third Party: Yes |