Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL10655-R4
Application Type Revision
Code Version 2017
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Simpson Strong-Tie Company
Address/Phone/Email 2151 S. Airport Drive
McKinney, TX 75069
(800) 999-5099   Ext 3131
crizer@strongtie.com
 
Authorized Signature Keith Cullum
kcullum@strongtie.com
 
Technical Representative Keith Cullum
Address/Phone/Email 2221 Country Lane
McKinney, TX 75069
(800) 999-5099   Ext 3027
kcullum@strongtie.com
 
Quality Assurance Representative Shelby Short
Address/Phone/Email 5956 W. Las Positas Boulevard
Pleasanton, CA 94588
(800) 999-5099
sshort@strongtie.com
 
Category Structural Components
Subcategory Wood Connectors
 
Compliance Method Evaluation Report from a Product Evaluation Entity
 
Evaluation Entity ICC Evaluation Service, LLC
Quality Assurance Entity Benchmark Holdings, L.L.C.
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Ted Berman, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL10655_R4_COI_ICC-ES Cert of Independence 2017-12-06.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
AISI S1002012
ANSI/AWC NDS2015
ASTM D71472005
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option C
 
Date Submitted 05/11/2018
Date Validated 05/16/2018
Date Pending FBC Approval
Date Approved 05/20/2018
 
Summary of Products
FL # Model, Number or Name Description
10655.1 HGUS26, HGUS28, HGUS210, HGUS26-2, HGUS28-2, HGUS210-2, HGUS26-3, HGUS28-3, HGUS210-3, HGUS212-3, HGUS214-3, HGUS26-4, HGUS28-4, HGUS210-4, HGUS212-4, HGUS214-4, HGUS46, HGUS48, HGUS410, HGUS412, HGUS414 Joist Hanger
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.2 HHUS26-2, HHUS28-2, HHUS210-2, HHUS46, HHUS48, HHUS410 Joist Hanger
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.3 HSUL26-2, HSUL210-2, HSUL214-2, HSUL46, HSUL410, HSUL414, HSUR26-2, HSUR210-2, HSUR214-2, HSUR46, HSUR410, HSUR414, HSULC26-2, HSULC210-2, HSULC214-2, HSULC46, HSULC410, HSULC414, HSURC26-2, HSURC210-2, HSURC214-2, HSURC46, HSURC410, HSURC414 Joist Hanger - Skewed Left or Right
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.4 HTU26, HTU28, HTU210, HTU26-2, HTU28-2, HTU210-2 Joist Hanger
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: If using HTU26 installed with minimum nailing in HVHZ to resist wind uplift, supplemental connectors are required to achieve minimum 700 pounds uplift.
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.5 HU24-2, HU26-2, HU28-2, HU210-2, HU212-2, HU214-2, HU216-2, HUC24-2, HUC26-2, HUC28-2, HUC210-2, HUC212-2, HUC214-2, HUC216-2 Joist Hanger
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: If using HU24-2 or HUC24-2 in HVHZ to resist wind uplift, supplemental connectors are required to achieve minimum 700 pounds uplift.
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.6 HU26, HU28, HU210, HU212, HU214, HU216, HU34, HU36, HU38, HU310, HU312, HU314, HU316, HUC34, HUC36, HUC38, HUC310, HUC312, HUC314, HUC316 Joist Hanger
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: If using HU26, HU28, HU210, HU34, HU36, HU38, HUC34, HUC36, or HUC38 in HVHZ to resist wind uplift, supplemental connectors are required to achieve minimum 700 pounds uplift.
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.7 HU26-3, HU210-3, HU212-3, HU214-3, HU216-3, HU310-2, HU312-2, HU314-2, HUC26-3, HUC210-3, HUC212-3, HUC214-3, HUC216-3, HUC310-2, HUC312-2, HUC314-2 Joist Hanger
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.8 HU44, HU46, HU48, HU410, HU412, HU414, HU416, HUC44, HUC46, HUC48, HUC410, HUC412, HUC414, HUC416 Joist Hanger
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: If using HU44 or HUC44 in HVHZ to resist wind uplift, supplemental connectors are required to achieve minimum 700 pounds uplift.
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.9 HU66, HU68, HU610, HU612, HU614, HU616, HU210-4, HUC66, HUC68, HUC610, HUC612, HUC614, HUC616, HUC210-4 Joist Hanger
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.10 HU88, HU810, HU812, HU814, HU816, HUC88, HUC810, HUC812, HUC814, HUC816 Joist Hanger
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.11 HUS26, HUS28, HUS210, HUS46, HUS48, HUS410, HUS412, HUS26-2, HUS28-2, HUS210-2, HUS212-2, HUSC46, HUSC48, HUSC410, HUSC412 Joist Hangers
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.12 LU24, LU26, LU28, LU210 Joist Hanger
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: If using LU24 or LU26 in HVHZ to resist wind uplift, supplemental connectors are required to achieve minimum 700 pounds uplift.
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.13 LUC26Z, LUC210Z Joist Hanger
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.14 LUS24, LUS26, LUS28, LUS210, LUS24-2, LUS26-2, LUS28-2, LUS210-2, LUS214-2, LUS26-3, LUS28-3, LUS210-3, LUS36, LUS44, LUS46, LUS48, LUS410, LUS414 Joist Hanger
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: If using LUS24, LUS24-2 or LUS44 in HVHZ to resist wind uplift, supplemental connectors are required to achieve minimum 700 pounds uplift.
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.15 MUS26, MUS28 Joist Hanger
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.16 SUL24, SUL26, SUL210, SUL214, SUL2.56/9, SUL2.56/11, SUR24, SUR26, SUR210, SUR214, SUR2.56/9, SUR2.56/11 Joist Hanger - Skewed Left or Right
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: If using SUL24, SUL26, SUL2.56/9, SUL2.56/11, SUR24, SUR26, SUR2.56/9, or SUR 2.56/11 in HVHZ to resist wind uplift, supplemental connectors are required to achieve minimum 700 pounds uplift.
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.17 SUL26-2, SUL210-2, SUL414, SUR26-2, SUR210-2, SUR414, SULC26-2, SULC210-2, SULC414, SURC26-2, SURC210-2, SURC414 Joist Hanger - Skewed Left or Right
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.18 U24, U26, U210, U214, U34, U36, U310, U314, U24-2, U26-2, U210-2, U44, U46, U410, U414, U26-3, U210-3, U66, U610 Joist Hanger
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: If using U24, U26, U34, U36, U24-2, U26-2, U44, U46, U26-3, or U66 in HVHZ to resist wind uplift, supplemental connectors are required to achieve minimum 700 pounds uplift.
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
10655.19 U24R, U26R, U210R, U44R, U46R, U410R, U66R, U610R Joist Hanger - Rough Size
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: If using U24R, U26R, U44R, U46R, or U66R in HVHZ to resist wind uplift, supplemental connectors are required to achieve minimum 700 pounds uplift.
Installation Instructions
 FL10655_R4_II_ESR-2549.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL10655_R4_AE_ESR-2549.pdf
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe