34563.1 |
01 - Inswing 8’O” Double Fiberglass Door Glazed |
Inswing 8’O” Double Fiberglass Door Glazed |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50.14/-50.14 Other: See uploaded test reports for detail. |
Installation Instructions FL34563_R1_II_Installation_e4545.04-801-44-r1.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX Test Reports FL34563_R1_TR_Test Report_D0644.01-121-24-R0.pdf FL34563_R1_TR_Test Report_e4545.04-801-44-r1.pdf |
|
34563.2 |
02 - Inswing 8’O” Single Fiberglass Door with Speak Easy |
Inswing 8’O” Single Fiberglass Door with Speak Easy |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50.14/-50.14 Other: See uploaded test reports for detail. |
Installation Instructions FL34563_R1_II_Installation_e4545.01-801-44-r2.pdf FL34563_R1_II_Installation_e4545.03-801-44-r2.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX Test Reports FL34563_R1_TR_Test Report_D0644.01-121-24-R0.pdf FL34563_R1_TR_Test Report_e4545.01-801-44-r2.pdf FL34563_R1_TR_Test Report_e4545.03-801-44-r2.pdf |
|
34563.3 |
03 - Inswing 8’O” Triple Fiberglass Door Glazed |
Inswing 8’O” Triple Fiberglass Door Glazed |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50.14/-50.14 Other: See uploaded test reports for detail. |
Installation Instructions FL34563_R1_II_Installation_e4545.04-801-44-r1.pdf FL34563_R1_II_Installation_e4545.05-801-44-r2.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX Test Reports FL34563_R1_TR_Test Report_D0644.01-121-24-R0.pdf FL34563_R1_TR_Test Report_e4545.04-801-44-r1.pdf FL34563_R1_TR_Test Report_e4545.05-801-44-r2.pdf |
|
34563.4 |
04 - Outswing 8’O” Double Fiberglass Door Glazed |
Outswing 8’O” Double Fiberglass Door Glazed |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50.14/-50.14 Other: See uploaded test reports for detail. |
Installation Instructions FL34563_R1_II_Installation_e4545.04-801-44-r1.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX Test Reports FL34563_R1_TR_Test Report_D0644.01-121-24-R0.pdf FL34563_R1_TR_Test Report_e4545.04-801-44-r1.pdf |
|
34563.5 |
05 - Outswing 8’O” Single Fiberglass Door with Speak Easy |
Outswing 8’O” Single Fiberglass Door with Speak Easy |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50.14/-50.14 Other: See uploaded test reports for detail. |
Installation Instructions FL34563_R1_II_Installation_e4545.01-801-44-r2.pdf FL34563_R1_II_Installation_e4545.02-801-44-r2.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX Test Reports FL34563_R1_TR_Test Report_D0644.01-121-24-R0.pdf FL34563_R1_TR_Test Report_e4545.01-801-44-r2.pdf FL34563_R1_TR_Test Report_e4545.02-801-44-r2.pdf |
|
34563.6 |
06 - Outswing 8’O” Tripple Fiberglass Door Glazed |
Outswing 8’O” Triple Fiberglass Door Glazed |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50.14/-50.14 Other: See uploaded test reports for detail. |
Installation Instructions FL34563_R1_II_Installation_e4545.04-801-44-r1.pdf FL34563_R1_II_Installation_e4545.06-801-44-r2.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - Plano, TX Test Reports FL34563_R1_TR_Test Report_D0644.01-121-24-R0.pdf FL34563_R1_TR_Test Report_e4545.04-801-44-r1.pdf FL34563_R1_TR_Test Report_e4545.06-801-44-r2.pdf |