FL # FL23225-R3
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Petersen Aluminum Corp.
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(954) 461-7055
ndelfino@petersenmail.com
 
Authorized Signature Sal Delfino
sdelfino@petersenmail.com
 
Technical Representative Sal Delfino
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(954) 931-1392
sdelfino@petersenmail.com
 
Quality Assurance Representative Nick Delfino
Address/Phone/Email 1500 N. University Drive
Suite 201-G
Coral Springs, FL 33071
(954) 461-7055
ndelfino@petersenmail.com
 
Category Panel Walls
Subcategory Siding
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Locke Bowden
Florida License PE-49704
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL23225_R3_COI_SS CERTIFICATE OF INDEPENDENCE.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM 15922005
ASTM E3302014
 
Equivalence of Product Standards
Certified By

Approved Testing Lab
FL23225_R3_Equiv_Petersen Aluminum equivalency letter-1.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/26/2020
Date Validated 10/21/2023
Date Pending FBC Approval 10/29/2023
Date Approved 12/13/2023
 
Summary of Products
          Page 1 / 3    
FL # Model, Number or Name Description
23225.1 [1] Flush Panel (.032") .032” (min.) Aluminum Wall Panel (with concealed clips)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-130
 Other: Span spacing: 12", 18", 24", 30", 36", 42", and 48", see load table attached.
Installation Instructions
 FL23225_R3_II_SS FL 23225.1 REPORT - INSTALL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_SS FL 23225.1 REPORT - INSTALL.pdf
 Created by Independent Third Party: Yes
23225.2 [2] Flush Panel (.032") .032" (min.) Aluminum Wall Panel (with back stitching)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-80
 Other: Span spacing: 12", 18", 24", 30", 36", 42", and 48", see load table attached.
Installation Instructions
 FL23225_R3_II_SS FL 23225.2 REPORT - INSTALL.pdf
 Verified By: Locke Boweden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_SS FL 23225.2 REPORT - INSTALL.pdf
 Created by Independent Third Party: Yes
23225.3 [3] Flush Panel (.040") .040" (min.) Aluminum Wall Panel (with back stitching)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-145
 Other: Span spacing: 12", 18", 24", 30", 36", 42", and 48", see load table attached.
Installation Instructions
 FL23225_R3_II_SS FL 23225.3 REPORT - INSTALL.pdf
 Verified By: Locke Boweden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_SS FL 23225.3 REPORT - INSTALL.pdf
 Created by Independent Third Party: Yes
23225.4 [4] Flush Panel (24 ga.) 24 ga. (min.) Steel Wall Panel (with concealed clips)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-95
 Other: Span spacing: 12", 18", 24", 30", 36", 42", 48", see load table attached.
Installation Instructions
 FL23225_R3_II_SS FL 23225.4 REPORT - INSTALL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_SS FL 23225.4 REPORT - INSTALL.pdf
 Created by Independent Third Party: Yes
23225.5 [5] Flush Panel (24 ga.) 24 ga. (min.) Steel Wall Panel (with back stitching)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-82.5
 Other: Span spacing: 24", 30", 36", 42", 48", 54" and 60", see load table attached.
Installation Instructions
 FL23225_R3_II_SS FL 23225.5 REPORT - INSTALL.pdf
 Verified By: Locke Boweden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_SS FL 23225.5 REPORT - INSTALL.pdf
 Created by Independent Third Party: Yes
23225.6 [6] Flush Panel (22 ga.) 22 ga. (min.) Steel Wall Panel (with back stitching)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-105
 Other: Span spacing: 24", 30", 36", 42", 48", 54" and 60", see load table attached.
Installation Instructions
 FL23225_R3_II_SS FL 23225.6 REPORT - INSTALL.pdf
 Verified By: Locke Boweden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_SS FL 23225.6 REPORT - INSTALL.pdf
 Created by Independent Third Party: Yes
23225.7 [7] Reveal Panel (.032") .032” (min.) Aluminum Wall Panel (with concealed clips)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-110
 Other: Span spacing: 12", 18", 24", 30", 36", 42", 48", see load table attached.
Installation Instructions
 FL23225_R3_II_SS FL 23225.7 REPORT - INSTALL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_SS FL 23225.7 REPORT - INSTALL.pdf
 Created by Independent Third Party: Yes
23225.8 [8] Reveal Panel (24 ga.) 24 ga. (min.) Steel Wall Panel (with concealed clips)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-103
 Other: Span spacing: 12", 18", 24", 30", 36", 42", 48", see load table attached.
Installation Instructions
 FL23225_R3_II_SS FL 23225.8 REPORT - INSTALL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_SS FL 23225.8 REPORT - INSTALL.pdf
 Created by Independent Third Party: Yes
23225.9 [9] R-36 Panel x 36" Wide 24 Gauge Steel, 22 Gauge Steel, .032" Aluminum, .040" Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL23225_R3_II_SS FL 23225.9 THRU .11 REPORTS - INSTALL.pdf
 Verified By: UL LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL23225_R3_AE_SS FL 23225.9 THRU .11 REPORTS - INSTALL.pdf
 Created by Independent Third Party: Yes
23225.10 2.67" x 7/8" Corrugated Panels 24 Gauge Steel, .032" Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL23225_R3_II_SS FL 23225.9 THRU .11 REPORTS - INSTALL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_SS FL 23225.9 THRU .11 REPORTS - INSTALL.pdf
 Created by Independent Third Party: Yes
23225.11 7.2" Rib Panel 24 Gauge Steel, .032" Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other:  
Installation Instructions
 FL23225_R3_II_SS FL 23225.9 THRU .11 REPORTS - INSTALL.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_SS FL 23225.9 THRU .11 REPORTS - INSTALL.pdf
 Created by Independent Third Party: Yes
23225.12 Highline Precision Series: B1 (11.356" nom.) 24 ga. (min.) steel with clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-181.27
 Other: See adjacent ASTM-E330 Load Table for specific spans and pressures.
Installation Instructions
 FL23225_R3_II_Clip Detail.pdf
 FL23225_R3_II_SS FL 23225 INSTALL DETAILS 6PG.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_FL23225_R3_AE_Highline Precision Load Tables Binder.pdf
 FL23225_R3_AE_SS 2023 FL 23225.12 THRU .51 REPORTS.pdf
 Created by Independent Third Party: Yes
23225.13 Highline Precision Series: B1 (11.356" nom.) 24 ga. (min.) steel without clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-153.73
 Other: See adjacent ASTM-E330 Load Table for specific spans and pressures.
Installation Instructions
 FL23225_R3_II_SS FL 23225 INSTALL DETAILS 10PG.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_FL23225_R3_AE_Highline Precision Load Tables Binder.pdf
 FL23225_R3_AE_SS 2023 FL 23225.12 THRU .51 REPORTS.pdf
 Created by Independent Third Party: Yes
23225.14 Highline Precision Series: B1 (11.356" nom.) .032" (min.) aluminum with clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-201.91
 Other: See adjacent ASTM-E330 Load Table for specific spans and pressures.
Installation Instructions
 FL23225_R3_II_SS FL 23225 INSTALL DETAILS 6PG.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_FL23225_R3_AE_Highline Precision Load Tables Binder.pdf
 FL23225_R3_AE_SS 2023 FL 23225.12 THRU .51 REPORTS.pdf
 Created by Independent Third Party: Yes
23225.15 Highline Precision Series: B1 (11.356" nom.) .032" (min.) aluminum without clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-124.45
 Other: See adjacent ASTM-E330 Load Table for specific spans and pressures.
Installation Instructions
 FL23225_R3_II_SS FL 23225 INSTALL DETAILS 10PG.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_FL23225_R3_AE_Highline Precision Load Tables Binder.pdf
 FL23225_R3_AE_SS 2023 FL 23225.12 THRU .51 REPORTS.pdf
 Created by Independent Third Party: Yes
23225.16 Highline Precision Series: B2 (15.356" nom.) 24 ga. (min.) steel without clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-165.73
 Other: See adjacent ASTM-E330 Load Table for specific spans and pressures.
Installation Instructions
 FL23225_R3_II_SS FL 23225 INSTALL DETAILS 10PG.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_FL23225_R3_AE_Highline Precision Load Tables Binder.pdf
 FL23225_R3_AE_SS 2023 FL 23225.12 THRU .51 REPORTS.pdf
 Created by Independent Third Party: Yes
23225.17 Highline Precision Series: B2 (15.356" nom.) 24 ga. (min.) steel with clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-152.45
 Other: See adjacent ASTM-E330 Load Table for specific spans and pressures.
Installation Instructions
 FL23225_R3_II_SS FL 23225 INSTALL DETAILS 6PG.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_FL23225_R3_AE_Highline Precision Load Tables Binder.pdf
 FL23225_R3_AE_SS 2023 FL 23225.12 THRU .51 REPORTS.pdf
 Created by Independent Third Party: Yes
23225.18 Highline Precision Series: B2 (15.356" nom.) .032" (min.) aluminum without clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-70.09
 Other: See adjacent ASTM-E330 Load Table for specific spans and pressures.
Installation Instructions
 FL23225_R3_II_SS FL 23225 INSTALL DETAILS 10PG.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_FL23225_R3_AE_Highline Precision Load Tables Binder.pdf
 FL23225_R3_AE_SS 2023 FL 23225.12 THRU .51 REPORTS.pdf
 Created by Independent Third Party: Yes
23225.19 Highline Precision Series: B2 (15.356" nom.) .032" (min.) aluminum with clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-142.09
 Other: See adjacent ASTM-E330 Load Table for specific spans and pressures.
Installation Instructions
 FL23225_R3_II_SS FL 23225 INSTALL DETAILS 6PG.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_FL23225_R3_AE_Highline Precision Load Tables Binder.pdf
 FL23225_R3_AE_SS 2023 FL 23225.12 THRU .51 REPORTS.pdf
 Created by Independent Third Party: Yes
23225.20 Highline Precision Series: C1 (11.356" nom.) 24 ga. (min.) steel with clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-227.91
 Other: See adjacent ASTM-E330 Load Table for specific spans and pressures.
Installation Instructions
 FL23225_R3_II_SS FL 23225 INSTALL DETAILS 6PG.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23225_R3_AE_FL23225_R3_AE_Highline Precision Load Tables Binder.pdf
 FL23225_R3_AE_SS 2023 FL 23225.12 THRU .51 REPORTS.pdf
 Created by Independent Third Party: Yes
          Page 1 / 3    
 