FL # FL14016-R4
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Central States Manufacturing, Inc.
Address/Phone/Email 302 Jane Place
Lowell, AR 72745
(479) 770-0188
mhowell@centralstatesmfg.com
 
Authorized Signature Michael Howell
mhowell@centralstatesmfg.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Structural Components
Subcategory Roof Deck
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Bala Sockalingam
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 07/16/2024
Validated By Yoosef Lavi, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL14016_R4_COI_CertificateIndependence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E15922005
FM 44711992
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 09/30/2020
Date Validated 10/01/2020
Date Pending FBC Approval 10/11/2020
Date Approved 12/15/2020
Date Revised 09/02/2023
 
Summary of Products
FL # Model, Number or Name Description
14016.1 Central Seam Plus Min. 24 ga., max. 24" wide standing seam roof panel with or without wind clamps over open supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-176.5
 Other: Without Wind Clamp, uplift load of 38.0 psf at clip spacing of 60" o.c. and 98.5 psf at clip spacing of 12" o.c. With Wind Clamps, uplift load of 56.8 psf at clip spacing of 60" o.c. and 176.5 psf at clip spacing of 12" o.c.
Installation Instructions
 FL14016_R4_II_EvaluationReportC2398_1.pdf
 Verified By: Bala Sockalingam, P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14016_R4_AE_EvaluationReportC2398_1.pdf
 Created by Independent Third Party: Yes
14016.2 Central Span 16" wide, min 24 ga. Standing Seam Panel over open supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-112.5
 Other: Maximum uplift load of 112.5 psf at support spacing of 24" o.c. with QuadLok seam.
Installation Instructions
 FL14016_R4_II_EvaluationReportC2398_2.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14016_R4_AE_EvaluationReportC2398_2.pdf
 Created by Independent Third Party: Yes
14016.3 Central-Loc Min. 24 ga., max. 24" wide snap lock roof panel over open supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5
 Other: Uplift load of 52.5 psf at clip spacing of 60" o.c.
Installation Instructions
 FL14016_R4_II_EvaluationReportC2398_3.pdf
 Verified By: Bala Sockalingam, P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14016_R4_AE_EvaluationReportC2398_3.pdf
 Created by Independent Third Party: Yes
14016.4 M-Loc Min. 26 ga., 36" wide, through fastened panel over open steel supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/--114.7
 Other: Uplift load of 43.2 psf at fastener spacing of 60" o.c. and 114.7 psf at fastener spacing of 24" o.c
Installation Instructions
 FL14016_R4_II_EvaluationReportC2398_4.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14016_R4_AE_EvaluationReportC2398_4.pdf
 Created by Independent Third Party: Yes
14016.5 R-Loc Min. 26 ga., 36" wide, through fastened panel over open steel supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-112.7
 Other: Uplift load of 44.2 psf at fastener spacing of 60" o.c. and 112.7 psf at fastener spacing of 24" o.c.
Installation Instructions
 FL14016_R4_II_EvaluationReportC2398_5.pdf
 Verified By: Bala Sockalingam, P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14016_R4_AE_EvaluationReportC2398_5.pdf
 Created by Independent Third Party: Yes
 