14071.1 |
Emerge E500 Slider |
AW Horizontal Sliding Window |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: AW-PG50 99" x 79" HS Nail Fin Anchorage. See Installation Instructions. |
Certification Agency Certificate FL14071_R8_C_CAC_NI011458-R1.pdf Quality Assurance Contract Expiration Date 11/30/2026 Installation Instructions FL14071_R8_II_E500 Non-Impact AW_PE Sealed.pdf Verified By: Tanya A. Dolby, P.E. FL #93536 Created by Independent Third Party: Yes Evaluation Reports FL14071_R8_AE_q8188.01-122-34-r0.pdf Created by Independent Third Party: Yes |
|
14071.2 |
Series "Emerge E700 Slider" |
Horizontal Sliding Window |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Refer to Installation Instructions, QWP020, and evaluation report, PER5620, for further limitations of use |
Certification Agency Certificate FL14071_R8_C_CAC_NI012201.03-R1.pdf Quality Assurance Contract Expiration Date 04/30/2028 Installation Instructions FL14071_R8_II_QWP020 SS 2023-12-21.pdf Verified By: Hermes F. Norero, PE FL #73778 Created by Independent Third Party: Yes Evaluation Reports FL14071_R8_AE_PER9025 SS 2023-12-21.pdf Created by Independent Third Party: Yes |
|
14071.3 |
Series "Emerge E700 Slider" w/Louver |
Horizontal Sliding Window w/Louver Below |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: CW-PG50 72" x 66" HS Over Fixed E700 Frame w/ 20-3/4" Louver. Overall dimsion of unit is 72" x 88-3/4". Missile Level D & Wind Zone 4. Nail Fin Anchorage. See Installation Instructions. Note: Louvers used in this unit are for use in conjunction with PTAC units only! |
Certification Agency Certificate FL14071_R8_C_CAC_NI012201.01-R1.pdf Quality Assurance Contract Expiration Date 04/30/2028 Installation Instructions FL14071_R8_II_E700 Impact CW with Louver_PE Sealed.pdf Verified By: Tanya A. Dolby, P.E. FL #93536 Created by Independent Third Party: Yes Evaluation Reports FL14071_R8_AE_q8188.01-122-34-r0.pdf Created by Independent Third Party: Yes |
|
14071.4 |
Series "Keystone" Model "K200 Slider" |
Horizontal Sliding Window |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Refer to installation instructions, QWP021, and evaluation report, for further limitations of use. |
Certification Agency Certificate FL14071_R8_C_CAC_NI011857-R2.pdf Quality Assurance Contract Expiration Date 01/31/2028 Installation Instructions FL14071_R8_II_QWP021 SS 2023-12-21.pdf Verified By: Hermes F. Norero, PE FL #73778 Created by Independent Third Party: Yes Evaluation Reports FL14071_R8_AE_PER9026 SS 2023-12-21.pdf Created by Independent Third Party: Yes |