FL # FL22001-R8
Application Type Affirmation
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Kolbe & Kolbe Millwork Co., Inc.
Address/Phone/Email 1323 S. 11th Ave
Wausau, WI 54401
(715) 847-0616
karen.long@kolbewindows.com
 
Authorized Signature Karen Long
karen.long@kolbewindows.com
 
Technical Representative Sue Schreiber
Address/Phone/Email 1323 S. 11th Ave.
Wausau, WI 54401
(715) 847-0736
SSchreiber@kolbe-kolbe.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Windows
Subcategory Casement
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA 4502010
AAMA/WDMA/CSA 101/I.S.2/A4402011
AAMA/WDMA/CSA 101/I.S.2/A4402017
ASTM E18862005
ASTM E18862013
ASTM E19962012
ASTM E19962014
ASTM E19962017
 
Equivalence of Product Standards
Certified By

Approved Certification Agency
FL22001_R8_Equiv_Equivalency bulletin 11-11-19.pdf
 
 
 
Documentation from approved Evaluation or Validation Entity
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 01/22/2024
Date Validated 01/22/2024
Date Pending FBC Approval
Date Approved 01/27/2024
 
Summary of Products
          Page 1 / 2    
FL # Model, Number or Name Description
22001.1 Heritage Series Operating Casement / Casement Picture 144" x 72" Integral & Combination Mulls, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Glass complies with the current ASTM E1300 standard; Wood frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 18148.pdf
Quality Assurance Contract Expiration Date
 03/25/2029
Installation Instructions
 FL22001_R8_II_18148 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.2 Heritage Series Operating Push Out Casement 36" x 72" Multi Point Lock, Impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-70
 Other: Glass complies with the current ASTM E1300 standard; (3.1 mm Ann or 3.1 mm T - 8.0 mm SS - 3.9 mm Ann .090" SGP 3.9 mm Ann), Missile Level D, Wind Zone 4, Insulated Glazed; Wood frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 17146.pdf
Quality Assurance Contract Expiration Date
 09/17/2028
Installation Instructions
 FL22001_R8_II_17146 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.3 Heritage Series Operating Push Out French Casement 48" x 48", Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-55
 Other: Glass complies with the current ASTM E1300 standard; Wood frame; Positive design pressure +55 psf
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 18099.pdf
Quality Assurance Contract Expiration Date
 08/29/2029
Installation Instructions
 FL22001_R8_II_18099 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.4 Heritage Series Operating Push Out French Casement 60" x 60", Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Glass complies with the current ASTM E1300 standard; Wood frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 18100.pdf
Quality Assurance Contract Expiration Date
 08/29/2029
Installation Instructions
 FL22001_R8_II_18100 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.5 Ultra Series Inswing French Casement 48" x 72", Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-35
 Other: Glass complies with the current ASTM E1300 standard; Alum clad frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 18008.pdf
Quality Assurance Contract Expiration Date
 08/09/2028
Installation Instructions
 FL22001_R8_II_18008 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.6 Ultra Series Operating Casement 72" x 72" Combination Mull, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +65/-70
 Other: Glass complies with the current ASTM E1300 standard; Alum clad frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 19106.pdf
Quality Assurance Contract Expiration Date
 09/02/2030
Installation Instructions
 FL22001_R8_II_19106 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.7 Ultra Series Operating Casement 36" x 90", Impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-70
 Other: Glass complies with the current ASTM E1300 standard; (3.9 mm Ann .090" SGP 3.9 mm Ann), Single Glazed; (3.1 mm Ann or 3.1 mm T- 8.0 mm SS - 3.9 mm Ann .090" SGP 3.9 mm Ann), Insulated Glazed; Missile Level D, Wind Zone 4; Alum clad frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 18004_65.pdf
Quality Assurance Contract Expiration Date
 07/20/2028
Installation Instructions
 FL22001_R8_II_18004_65 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.8 Ultra Series Operating Casement / Casement Picture 96-1/4" x 120-1/4" Reinforced Combination Mulls, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +65/-70
 Other: Glass complies with the current ASTM E1300 standard; Alum clad frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 20005.pdf
Quality Assurance Contract Expiration Date
 06/22/2030
Installation Instructions
 FL22001_R8_II_20005 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.9 Ultra Series Operating Casement / Casement Picture 96-1/4" x 120" Reinforced & Non-reinforced Combination Mulls, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Glass complies with the current ASTM E1300 standard; Alum clad frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 19063.pdf
Quality Assurance Contract Expiration Date
 03/09/2030
Installation Instructions
 FL22001_R8_II_19063 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.10 Ultra Series Operating Casement / Casement Picture 144" x 72", Integral mullions, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +65/-65
 Other: Glass complies with the current ASTM E1300 standard; Alum clad frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 18154.pdf
Quality Assurance Contract Expiration Date
 11/26/2029
Installation Instructions
 FL22001_R8_II_18154 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.11 Ultra Series Operating EP Pushout Casement 36" x 72" Single Point Lock, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +55/-55
 Other: Glass complies with the current ASTM E1300 standard; Alum clad frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 15004.pdf
Quality Assurance Contract Expiration Date
 08/11/2025
Installation Instructions
 FL22001_R8_II_15004 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.12 Ultra Series Operating EP Pushout Casement 36" x 72" Multi Point Lock, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +65/-70
 Other: Glass complies with the current ASTM E1300 standard; Alum clad frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 15005.pdf
Quality Assurance Contract Expiration Date
 05/22/2025
Installation Instructions
 FL22001_R8_II_15005 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.13 Ultra Series Operating Push Out Casement 36" x 90" Multi Point Lock, Impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-75
 Other: Glass complies with the current ASTM E1300 standard; (3.9 mm Ann .090" SGP 3.9 mm Ann), Single Glazed; (3.1 mm Ann or 3.1 mm T- 8.0 mm SS - 3.9 mm Ann .090" SGP 3.9 mm Ann), Insulated Glazed; Missile Level D, Wind Zone 4; Alum clad frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 16085_86.pdf
Quality Assurance Contract Expiration Date
 11/11/2026
Installation Instructions
 FL22001_R8_II_16085_86 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.14 Ultra Series Operating Push Out Casement 36" x 72", Single point lock, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +55/-55
 Other: Glass complies with the current ASTM E1300 standard; Alum clad frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 18122.pdf
Quality Assurance Contract Expiration Date
 12/26/2029
Installation Instructions
 FL22001_R8_II_18122 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.15 Ultra Series Operating Push Out Casement 24" x 42", Single point lock, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +65/-65
 Other: Glass complies with the current ASTM E1300 standard; Alum clad frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 18123.pdf
Quality Assurance Contract Expiration Date
 09/25/2029
Installation Instructions
 FL22001_R8_II_18123 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.16 Ultra Series Operating Push Out Casement 36" x 42", Single point lock, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Glass complies with the current ASTM E1300 standard; Alum clad frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 19093.pdf
Quality Assurance Contract Expiration Date
 11/27/2029
Installation Instructions
 FL22001_R8_II_19093 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.17 Ultra Series Operating Radius Crank-Out Casement 36" x 72", Impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-70
 Other: Glass complies with the current ASTM E1300 standard; (3.1 mm Ann .090" SGP 3.1 mm Ann), Single Glazed; (3.1 mm Ann or 3.1 mm T- 9.8 mm SS - 3.1 mm Ann .090" SGP 3.1 mm Ann), Insulated Glazed; Missile Level D, Wind Zone 4; Alum clad frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 18032-37.pdf
Quality Assurance Contract Expiration Date
 01/16/2029
Installation Instructions
 FL22001_R8_II_18032-37 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.18 Ultra Series Operating Radius Push Out Casement 36" x 72" Multi Point Lock, Impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-65
 Other: Glass complies with the current ASTM E1300 standard; (3.9 mm Ann .090" SGP 3.9 mm Ann), Single Glazed; (3.1 mm Ann or 3.1 mm T- 8.0 mm SS - 3.9 mm Ann .090" SGP 3.9 mm Ann), Insulated Glazed; Missile Level D, Wind Zone 4; Alum clad frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 16087-92.pdf
Quality Assurance Contract Expiration Date
 10/05/2026
Installation Instructions
 FL22001_R8_II_16087_90 string.pdf
 FL22001_R8_II_16088_91 string.pdf
 FL22001_R8_II_16089_92 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.19 Ultra Series Operating Radius Push Out Casement 36" x 72" Single Point Lock, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-55
 Other: Glass complies with the current ASTM E1300 standard; Alum clad frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 19035-39.pdf
Quality Assurance Contract Expiration Date
 07/09/2029
Installation Instructions
 FL22001_R8_II_19035, 19037, 19039 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
22001.20 Ultra Series Operating Radius Push Out Casement 36" x 72", Multi point lock, Non-impact
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Glass complies with the current ASTM E1300 standard; Alum clad frame
Certification Agency Certificate
 FL22001_R8_C_CAC_CCL 21076.pdf
Quality Assurance Contract Expiration Date
 01/05/2032
Installation Instructions
 FL22001_R8_II_21074,75,76 string.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
          Page 1 / 2    
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe