Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL15444-R7
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Jeld-Wen
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls, OR 97601
(541) 850-2650
rfricks@jeldwen.com
 
Authorized Signature Rylee Fricks
rfricks@jeldwen.com
 
Technical Representative JELD-WEN Corporate Customer Service
Address/Phone/Email 3737 Lakeport Blvd.
Klamath Falls, OR 97601
(800) 535-3936
customerserviceagents@jeld-wen.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Hermes F. Norero, P.E.
Florida License PE-73778
Quality Assurance Entity Window and Door Manufacturers Association-QA
Quality Assurance Contract Expiration Date 12/31/2030
Validated By Zachary R. Priest, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL15444_R7_COI_COI JW SS 2020-08-08.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/01/2023
Date Validated 08/21/2023
Date Pending FBC Approval 08/25/2023
Date Approved 10/17/2023
 
Summary of Products
FL # Model, Number or Name Description
15444.1 Custom Clad (A) Outswing French Door 75-3/16" X 98-1/8" Insulated Glass (5/16 in LAM SGP - 3/16 out Temp) or Single Glaze (7/16 LAM SGP Annealed) 8-0 system with 1-3/4" panels
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +60/-80
 Other:  
Installation Instructions
 FL15444_R7_II_JW016 SS 2023-04-04.pdf
 Verified By: Hermes F. Norero, P.E. # 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15444_R7_AE_PER8297 SS 2023-04-04.pdf
 Created by Independent Third Party: Yes
15444.2 Custom Clad (B) Outswing French Door 87x122 Insulated Glass (5/16 LAM PVB or SGP - 3/16 out Annealed) 10-0 system with 2-1/4" panels
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-65
 Other:  
Installation Instructions
 FL15444_R7_II_JW023 SS 2023-04-04.pdf
 Verified By: Hermes F. Norero, P.E. # 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15444_R7_AE_PER8298 SS 2023-04-04.pdf
 Created by Independent Third Party: Yes
15444.3 Custom Clad (C) Outswing Single & French Door, Fixed Door & Fixed Transom Mulled Combination Unit (Clipped) 153-3/16” X 129-1/8” Single Glaze (7/16 LAM PVB Annealed) or Insulated Glass (5/16 in LAM PVB - 3/16 out Tempered) 8-0 system with 1-3/4" panels
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +30/-30
 Other:  
Installation Instructions
 FL15444_R7_II_JW016 SS 2023-04-04.pdf
 Verified By: Hermes F. Norero, P.E. # 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15444_R7_AE_PER8297 SS 2023-04-04.pdf
 Created by Independent Third Party: Yes
15444.4 Custom Clad (D) Outswing Single & French Door, Fixed Door Mulled Combination Unit (Clipped) 153-3/16" X 98-1/8" Insulated Glass (5/16 in LAM SGP - 3/16 out Tempered) or Single Glaze (7/16 LAM SGP Annealed) 8-0 system with 1-3/4" panels
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +60/-80
 Other:  
Installation Instructions
 FL15444_R7_II_JW016 SS 2023-04-04.pdf
 Verified By: Hermes F. Norero, P.E. # 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15444_R7_AE_PER8297 SS 2023-04-04.pdf
 Created by Independent Third Party: Yes
15444.5 Custom Clad (E) Outswing Single Door 38" X 98-1/8" Insulated Glass (5/16 in LAM SGP - 3/16 out Temp) or Single Glaze (7/16 LAM SGP Annealed) 8-0 system with 1-3/4" panels
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +60/-80
 Other:  
Installation Instructions
 FL15444_R7_II_JW016 SS 2023-04-04.pdf
 Verified By: Hermes F. Norero, P.E. # 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15444_R7_AE_PER8297 SS 2023-04-04.pdf
 Created by Independent Third Party: Yes
15444.6 Custom Clad (F) Outswing Single Door 44x122 Insulated Glass ( 5/16 in LAM PVB or SGP - 3/16 out Temp) or (5/16 in LAM SPG - 3/16 out Annealed) 10-0 system with 2-1/4" panels
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-65
 Other:  
Installation Instructions
 FL15444_R7_II_JW023 SS 2023-04-04.pdf
 Verified By: Hermes F. Norero, P.E. # 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15444_R7_AE_PER8298 SS 2023-04-04.pdf
 Created by Independent Third Party: Yes
15444.7 Custom Clad (G) Outswing Single Fixed Door 44x122 Insulated Glass ( 5/16 in LAM PVB or SGP - 3/16 out Temp) or (5/16 in LAM SPG - 3/16 out Annealed) 10-0 system with 2-1/4" panels
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-65
 Other:  
Installation Instructions
 FL15444_R7_II_JW023 SS 2023-04-04.pdf
 Verified By: Hermes F. Norero, P.E. # 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15444_R7_AE_PER8298 SS 2023-04-04.pdf
 Created by Independent Third Party: Yes
15444.8 Custom Clad (H) Outswing Single, French, Fixed Door & any Mulled Combination Unit (un-clipped) 177x122 Insulated Glass ( 5/16 in LAM PVB or SGP - 3/16 out Temp) or (5/16 in LAM SPG - 3/16 out Annealed) 10-0 system with 2-1/4" panels
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-65
 Other:  
Installation Instructions
 FL15444_R7_II_JW023 SS 2023-04-04.pdf
 Verified By: Hermes F. Norero, P.E. # 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15444_R7_AE_PER8298 SS 2023-04-04.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe