15446.1 |
Custom Clad (A) |
Outswing Single & French Door (Includes Radius Top) 75-3/16" X 98-1/8" IG (5/16 LAM SGP Annealed in - 3/16 Tempered out) 8-0 system with 1-3/4" panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Multi-Point Hardware: 3 Point Active Panel, 2 Point Passive Panel |
Installation Instructions FL15446_R10_II_JW018 SS 2020-10-26.pdf Verified By: Hermes F. Norero, P.E. # 73778 Created by Independent Third Party: Yes Evaluation Reports FL15446_R10_AE_PER2860 SS 2020-10-26.pdf Created by Independent Third Party: Yes |
|
15446.2 |
Custom Clad (B) |
Outswing French Door (Includes Radius Top), with Fixed Door & Transom Mulled Unit (Clipped) 153-3/16” X 129-1/8” IG (5/16 LAM SGP annealed in - 3/16 Tempered out) 8-0 system with 1-3/4" panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Multi-Point Hardware: 3 Point Active Panel, 2 Point Passive Panel |
Installation Instructions FL15446_R10_II_JW018 SS 2020-10-26.pdf Verified By: Hermes F. Norero, P.E. # 73778 Created by Independent Third Party: Yes Evaluation Reports FL15446_R10_AE_PER2860 SS 2020-10-26.pdf Created by Independent Third Party: Yes |
|
15446.3 |
Custom Clad (C) |
Outswing Single & French Door (Includes Radius Top), with Fixed Door & Transom Mulled Unit (Clipped) 153-3/16" X 98-1/8" IG (5/16 LAM PVB in - 3/16 Tempered out) 8-0 system with 1-3/4" panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Multi-Point Hardware: 3 Point Active Panel, 2 Point Passive Panel |
Installation Instructions FL15446_R10_II_JW018 SS 2020-10-26.pdf Verified By: Hermes F. Norero, P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL15446_R10_AE_PER2860 SS 2020-10-26.pdf Created by Independent Third Party: Yes |
|
15446.4 |
Custom Clad (D) |
Outswing Single & French Door (Includes Radius Top) 75-3/16" X 98-1/8" IG (5/16 LAM PVB Annelaed - 3/16 Tempered out) 8-0 system with 1-3/4" panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Multi-Point Hardware: 3 Point Active Panel, 2 Point Passive Panel |
Installation Instructions FL15446_R10_II_JW018 SS 2020-10-26.pdf Verified By: Hermes F. Norero, P.E. # 73778 Created by Independent Third Party: Yes Evaluation Reports FL15446_R10_AE_PER2860 SS 2020-10-26.pdf Created by Independent Third Party: Yes |