FL # FL21443-R6
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Structall Building Systems, Inc.
Address/Phone/Email 350 Burbank Rd.
Oldsmar, FL 34677
(813) 855-2627
info@structall.com
 
Authorized Signature Mark Van Dame
info@structall.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative Joe Dean
Address/Phone/Email 350 Burbank Rd
Oldsmar, FL 34677
(813) 855-2627
jdean@structall.com
 
Category Roofing
Subcategory Products Introduced as a Result of New Technology
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Do Kim
Florida License PE-49497
Quality Assurance Entity ICC NTA dba ICC-ES
Quality Assurance Contract Expiration Date 12/31/2027
Validated By James L. Buckner, P.E. @ CBUCK Engineering
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL21443_R6_COI_certificate of independence.pdf
 
Referenced Standard and Year (of Standard)
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
1708.2
 
 
 
Product Approval Method Method 2 Option B
 
Date Submitted 08/01/2024
Date Validated 08/02/2024
Date Pending FBC Approval 08/03/2024
Date Approved 10/15/2024
 
Summary of Products
FL # Model, Number or Name Description
21443.1 Snap-N-Lock Composite Panel 3"x0.024"x1lb EPS Composite Panel
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +86.6/-86.6
 Other: In HVHZ, product shall be used in structures meeting the requirements of FBC Section 1626.1, unless impact protection is provided. See installation drawing for design pressures and spans.
Installation Instructions
 FL21443_R6_II_2023 FBC Structall 3x024x1lb.pdf
 Verified By: PRI Construction Materials Technologies, LLC
 Created by Independent Third Party: Yes
Evaluation Reports
 FL21443_R6_AE_Structall Evaluation Report-2023 FBC-R6.pdf
 Created by Independent Third Party: Yes
21443.2 Snap-N-Lock Composite Panel 3"x0.030"x1lb EPS Composite Panel
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +86.6/-86.6
 Other: In HVHZ, product shall be used in structures meeting the requirements of FBC Section 1626.1, unless impact protection is provided. See installation drawing for design pressures and spans.
Installation Instructions
 FL21443_R6_II_2023 FBC Structall 3x030x1lb.pdf
 Verified By: PRI Construction Materials Technologies, LLC
 Created by Independent Third Party: Yes
Evaluation Reports
 FL21443_R6_AE_Structall Evaluation Report-2023 FBC-R6.pdf
 Created by Independent Third Party: Yes
21443.3 Snap-N-Lock Composite Panel 3"x0.024"x2lb EPS Composite Panel
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +86.6/-86.6
 Other: In HVHZ, product shall be used in structures meeting the requirements of FBC Section 1626.1, unless impact protection is provided. See installation drawing for design pressures and spans.
Installation Instructions
 FL21443_R6_II_2023 FBC Structall 3x024x2lb.pdf
 Verified By: PRI Construction Materials Technologies, LLC
 Created by Independent Third Party: Yes
Evaluation Reports
 FL21443_R6_AE_Structall Evaluation Report-2023 FBC-R6.pdf
 Created by Independent Third Party: Yes
21443.4 Snap-N-Lock Composite Panel 4"x0.024"x1lb EPS Composite Panel
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +86.6/-86.6
 Other: In HVHZ, product shall be used in structures meeting the requirements of FBC Section 1626.1, unless impact protection is provided. See installation drawing for design pressures and spans.
Installation Instructions
 FL21443_R6_II_2023 FBC Structall 4x024x1lb.pdf
 Verified By: PRI Construction Materials Technologies, LLC
 Created by Independent Third Party: Yes
Evaluation Reports
 FL21443_R6_AE_Structall Evaluation Report-2023 FBC-R6.pdf
 Created by Independent Third Party: Yes
 