5562.1 |
1. Tite-Loc Plus Steel Panel |
2" High, 18" Wide x 24 Ga. (min.) Steel Panels over 16 Ga. (min.) Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-99.4 Other: Uplift load of 31.8 psf @ clip spacing of 5'-0" o.c. and 99.4 psf @ clip spacing of 2'-0" o.c. Install per manufacturer's details. Not for use in HVHZ. |
Installation Instructions FL5562_R11_II_EvaluationReportC2699_1.pdf Verified By: Bala Sockalingam 62240 Created by Independent Third Party: Yes Evaluation Reports FL5562_R11_AE_EvaluationReportC2699_1.pdf Created by Independent Third Party: Yes |
|
5562.2 |
2. Tite-Loc Plus Aluminum Panel |
2" High, 16" Wide x 0.032" (min.) Aluminum Panels over 16 Ga. (min.) Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-57.4 Other: Uplift load of 23.6 psf @ clip spacing of 5'-0" o.c. and 57.4 psf @ clip spacing of 2'-0" o.c. Install per manufacturer's details. Not for use in HVHZ. |
Installation Instructions FL5562_R11_II_EvaluationReportC2699_2.pdf Verified By: Bala Sockalingam 62240 Created by Independent Third Party: Yes Evaluation Reports FL5562_R11_AE_EvaluationReportC2699_2.pdf Created by Independent Third Party: Yes |
|
5562.3 |
3. Tite-Loc Plus Aluminum Panel |
2" High, 18" Wide x 0.032" (min.) Aluminum Panels over 16 Ga. (min.) Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.2 Other: Uplift load of 21.0 psf @ clip spacing of 5'-0" o.c. and 52.2 psf @ clip spacing of 2'-0" o.c. Install per manufacturer's details. Not for use in HVHZ. |
Installation Instructions FL5562_R11_II_EvaluationReportC2699_3.pdf Verified By: Bala Sockalingam 62240 Created by Independent Third Party: Yes Evaluation Reports FL5562_R11_AE_EvaluationReportC2699_3.pdf Created by Independent Third Party: Yes |
|
5562.4 |
4. Tite-Loc Plus Aluminum Panel |
2" High, 18" Wide x 0.040" (min.) Aluminum Panels over 16 Ga. (min.) Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-202.5 Other: Uplift load of 56.0 psf @ clip spacing of 5'-0" o.c. and 202.5 psf @ clip spacing of 1'-0" o.c. Install per manufacturer's details. Not for use in HVHZ. |
Installation Instructions FL5562_R11_II_EvaluationReportC2699_4.pdf Verified By: Bala Sockalingam 62240 Created by Independent Third Party: Yes Evaluation Reports FL5562_R11_AE_EvaluationReportC2699_4.pdf Created by Independent Third Party: Yes |