| 27680.1 |
Heritage Series Outswing French Entrance Door w/Fixed Door |
113.00" x 98.59" Combination Mull, Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: 3-point lock on active panel and 2-point handle activated shoot bolt lock system on passive panel. Glass complies with the current ASTM E1300 standard; Wood frame |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 19043.pdf Quality Assurance Contract Expiration Date 06/24/2029 Installation Instructions FL27680_R6_II_19043 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27680.2 |
Heritage Series Outswing French Entrance Door w/Transom |
74.88" x 128.09" Combination Mull, Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: 3-point lock on active panel and 2-point handle activated shoot bolt lock system on passive panel. Glass complies with the current ASTM E1300 standard; Wood frame |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 19028.pdf Quality Assurance Contract Expiration Date 05/31/2029 Installation Instructions FL27680_R6_II_19028 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27680.3 |
Ultra Series Inswing Entrance Door, 2.25" Panel |
37.63" x 122.72", Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: 3-point lock on active panel. Glass complies with the current ASTM E1300 standard. Doors are available with & without raised panels in designs both with glass & full raised panels (no glass), in accordance with the following guidelines – maximum raised panel height is 62”, maximum mid/cross rail length is 28-1/8”; Alum clad frame |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 19060.pdf Quality Assurance Contract Expiration Date 12/05/2029 Installation Instructions FL27680_R6_II_19060 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27680.4 |
Ultra Series Inswing French Entrance Door |
74.19" x 98.72", Non-impact, LBC |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-45 Other: 5-point lock on active panel and 2-point handle activated shoot bolt lock system on passive panel. Glass complies with the current ASTM E1300 standard. Doors are available with & without raised panels in designs both with glass & full raised panels (no glass), in accordance with the following guidelines – maximum raised panel height is 62”, maximum mid/cross rail length is 28-1/8”; Alum clad frame; Positive design pressure +45 psf |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 21091.pdf Quality Assurance Contract Expiration Date 08/09/2032 Installation Instructions FL27680_R6_II_21091 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27680.5 |
Ultra Series Inswing French Entrance Door |
37.5625" x 98.75", Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: HLS2000 3 Point Lock. Glass complies with the current ASTM E1300 standard. Doors are available with & without raised panels in designs both with glass & full raised panels (no glass), in accordance with the following guidelines – maximum raised panel height is 62”, maximum mid/cross rail length is 28-1/8”; Alum clad frame |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 21058.pdf Quality Assurance Contract Expiration Date 08/11/2031 Installation Instructions FL27680_R6_II_21058, 22064 String.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27680.6 |
Ultra Series Inswing French Entrance Door, 2.25" Panels |
74.19" x 122.72", Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: 5-point lock on active panel and 2-point handle activated shoot bolt lock system on passive panel. Glass complies with the current ASTM E1300 standard. Doors are available with & without raised panels in designs both with glass & full raised panels (no glass), in accordance with the following guidelines – maximum raised panel height is 62”, maximum mid/cross rail length is 28-1/8”; Alum clad frame |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 21035.pdf Quality Assurance Contract Expiration Date 11/16/2031 Installation Instructions FL27680_R6_II_21035 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27680.7 |
Ultra Series Inswing French Entrance Door, 2.25" Panels |
74.19" x 122.72", Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-35 Other: 3-point lock on active panel and 2-point handle activated shoot bolt lock system on passive panel. Glass complies with the current ASTM E1300 standard. Doors are available with & without raised panels in designs both with glass & full raised panels (no glass), in accordance with the following guidelines – maximum raised panel height is 62”, maximum mid/cross rail length is 28-1/8”; Alum clad frame |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 19061.pdf Quality Assurance Contract Expiration Date 01/03/2030 Installation Instructions FL27680_R6_II_19061 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27680.8 |
Ultra Series Outswing French Entrance Door w/Transom |
74.88" x 158.88" Steel Reinforced Combination Mull, Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-65 Other: 5-point lock on active panel and 2-point handle activated shoot bolt lock system on passive panel. Glass complies with the current ASTM E1300 standard. Doors are available with & without raised panels in designs both with glass & full raised panels (no glass), in accordance with the following guidelines – maximum raised panel height is 62”, maximum mid/cross rail length is 28-1/8”; Alum clad frame |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 17095.pdf Quality Assurance Contract Expiration Date 03/29/2028 Installation Instructions FL27680_R6_II_17095 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27680.9 |
Ultra Series Outswing French Entrance Door w/Transom |
74.88" x 158.88" Steel Reinforced Combination Mull, Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: 5-pt lock on active panel and 2-pt handle activated shoot bolt lock system on passive panel; Glass complies with the current ASTM E1300 standard (3.9 mm Ann .090" SGP 3.9 mm Ann), Single Glazed, Impact Performance, Missile D, Wind Zone 4; Doors are available with & without raised panels in designs both with glass & full raised panels (no glass), in accordance with the following guidelines – maximum raised panel height is 62”, maximum mid/cross rail length is 28-1/8”; Alum clad frame |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 17096.pdf Quality Assurance Contract Expiration Date 10/26/2027 Installation Instructions FL27680_R6_II_17096 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27680.10 |
Ultra Series Outswing French Entrance Door, 2.25" Panels |
74.88" x 122.59", Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-55 Other: 5-pt lock on active panel and 2-pt edge activated flushbolt lock system on passive panel; Glass complies with the current ASTM E1300 standard (3.9 mm Ann .090" PVB 3.9 mm Ann), Single Glazed, Impact Performance, Missile D, Wind Zone 3; Doors are available with & without raised panels in designs both with glass & full raised panels (no glass), in accordance with the following guidelines – maximum raised panel height is 62”, maximum mid/cross rail length is 28-1/8”; Alum clad frame |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 19132_20040.pdf Quality Assurance Contract Expiration Date 08/28/2030 Installation Instructions FL27680_R6_II_19132_20040 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27680.11 |
VistaLuxe Collection Inswing Entrance Door |
37.63" x 98.13", Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: 3-point lock on active panel. Glass complies with the current ASTM E1300 standard; Alum clad frame |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 20028.pdf Quality Assurance Contract Expiration Date 08/05/2031 Installation Instructions FL27680_R6_II_20028 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27680.12 |
VistaLuxe Collection Inswing Entrance Door, 2.25" Panel |
37.63" x 122.13", Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: 5-point lock on active panel. Glass complies with the current ASTM E1300 standard; Alum clad frame |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 20030.pdf Quality Assurance Contract Expiration Date 01/29/2031 Installation Instructions FL27680_R6_II_20030 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27680.13 |
VistaLuxe Collection Inswing French Entrance Door |
74.19" x 98.13", Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: 3-point lock on active panel and 2-point handle activated shoot bolt lock system on passive panel. Glass complies with the current ASTM E1300 standard; Alum clad frame |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 20029.pdf Quality Assurance Contract Expiration Date 08/05/2031 Installation Instructions FL27680_R6_II_20029 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27680.14 |
VistaLuxe Collection Inswing French Entrance Door |
74.19" x 98.13", Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-50 Other: 5-point lock on active panel and 2-point handle activated shoot bolt lock system on passive panel. Glass complies with the current ASTM E1300 standard; Alum clad frame; Positive design pressure +50 psf |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 17141.pdf Quality Assurance Contract Expiration Date 06/14/2028 Installation Instructions FL27680_R6_II_17141 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27680.15 |
VistaLuxe Collection Outswing Entrance Door, 2.25" Panel |
38.22" x 122.38", Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: 5-point lock on active panel. Glass complies with the current ASTM E1300 standard; Alum clad frame |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 20034.pdf Quality Assurance Contract Expiration Date 04/27/2031 Installation Instructions FL27680_R6_II_20034 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27680.16 |
VistaLuxe Collection Outswing French Entrance Door, 2.25" Panels |
74.88" x 98.38", Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: 5-point lock on active panel and 2-point handle activated shoot bolt lock system on passive panel. Glass complies with the current ASTM E1300 standard; Alum clad frame |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 21029.pdf Quality Assurance Contract Expiration Date 06/28/2031 Installation Instructions FL27680_R6_II_21029 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 27680.17 |
VistaLuxe Collection Outswing French Entrance Door, 2.25" Panels |
74.88" x 98.38", Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: 3-point lock on active panel and 2-point handle activated shoot bolt lock system on passive panel. Glass complies with the current ASTM E1300 standard; Alum clad frame |
Certification Agency Certificate FL27680_R6_C_CAC_CCL 21030.pdf Quality Assurance Contract Expiration Date 06/10/2031 Installation Instructions FL27680_R6_II_21030 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |