23157.1 |
Flush Panel (.032" min.) |
12" wide x .032" (min.) Aluminum Soffit Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-80 Other: Span spacing: 12", 18", 24", 30", 36", 42", and 48",
see load table attached. |
Installation Instructions FL23157_R2_II_SS FL 23157.1 REPORT AND INSTALL DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23157_R2_AE_SS FL 23157.1 REPORT AND INSTALL DETAILS.pdf Created by Independent Third Party: Yes |
|
23157.2 |
Flush Panel (.040" min.) |
12" wide x .040" (min.) Aluminum Soffit Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-290 Other: Span spacing: 12", 18", 24", 30", 36", 42", and 48",
see load table attached. |
Installation Instructions FL23157_R2_II_SS FL 23157.2 REPORT AND INSTALL DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23157_R2_AE_SS FL 23157.2 REPORT AND INSTALL DETAILS.pdf Created by Independent Third Party: Yes |
|
23157.3 |
Flush Panel (22 ga. min.) |
12" wide x 22 ga. (min.) Steel Soffit Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-210 Other: 24", 30", 36", 42", 48", 54" and 60", see load table
attached. |
Installation Instructions FL23157_R2_II_SS FL 23157.3 REPORT AND INSTALL DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23157_R2_AE_SS FL 23157.3 REPORT AND INSTALL DETAILS.pdf Created by Independent Third Party: Yes |
|
23157.4 |
Flush Panel (24 ga. min.) |
12" wide x 24 ga. (min.) Steel Soffit Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-165 Other: 24", 30", 36", 42", 48", 54" and 60", see load table
attached. |
Installation Instructions FL23157_R2_II_SS FL 23157.4 REPORT AND INSTALL DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23157_R2_AE_SS FL 23157.4 REPORT AND INSTALL DETAILS.pdf Created by Independent Third Party: Yes |
|
23157.5 |
PAC-850 .032" (min.) Aluminum Soffit |
PAC-850 Aluminum Soffit x 12" wide, .032" (min.) Aluminum Soffit, Solid, Fully-Vented or 1/2 Vented. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-110.9 Other: -24.27 psf @ 4'-0" o.c. -110.93 psf @1'-0" o.c.
Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL23157_R2_II_SS 23157.5 install details.pdf Verified By: Terrance E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL23157_R2_AE_SS FL 23157.5 REPORT.pdf Created by Independent Third Party: Yes |
|
23157.6 |
PAC-850 .032" (min.) Aluminum Soffit |
PAC-850 Aluminum Soffit x 12" wide, .032" (min.) Aluminum Soffit, Solid, Fully-Vented or 1/2 Vented. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-100 Other: Approved for use in HVHZ |
Installation Instructions FL23157_R2_II_SS 23157.6 install details.pdf Verified By: C. K. Brasher, P.E. 11140 Created by Independent Third Party: Yes Evaluation Reports FL23157_R2_AE_SS FL 23157.6 REPORT.pdf Created by Independent Third Party: Yes |