29523.1 |
01: 100SL 1" Nailstrip 032 Aluminum |
100SL 1" Nailstrip panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.5 Other: 168.5 psf @ 6" oc |
Installation Instructions FL29523_R4_II_32Al_100SL_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29523_R4_AE_32Al_100SL_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
29523.2 |
02: 100SL 1" Nailstrip 24ga |
100SL 1" Nailstrip panel from 24ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-206 Other: 206 psf @ 6 " oc |
Installation Instructions FL29523_R4_II_24ga_100SL_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29523_R4_AE_24ga_100SL_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
29523.3 |
03: 100SL 1" Nailstrip 26ga HVHZ |
100SL 1" Nailstrip panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-176 Other: 176 psf @ 6" oc WITH sealant, 116 psf @ 6" oc without sealant |
Installation Instructions FL29523_R4_II_26ga_100SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29523_R4_AE_26ga_100SL_plywood.pdf Created by Independent Third Party: Yes |
|
29523.4 |
04: 100SL 1" Nailstrip 032 Aluminum HVHZ |
100SL 1" Nailstrip panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-175 Other: 175 psf @ 6" oc WITH sealant |
Installation Instructions FL29523_R4_II_32Al_100SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29523_R4_AE_32Al_100SL_plywood.pdf Created by Independent Third Party: Yes |
|
29523.5 |
05: 150SL 1.5" Nailstrip 24ga |
150SL 1.5" Nailstrip panel from 24ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5 Other: 153.5 psf @ 6" oc WITH sealant |
Installation Instructions FL29523_R4_II_24ga_150SL_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29523_R4_AE_24ga_150SL_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
29523.6 |
06: 150SL 1.5" Nailstrip 032 Aluminum |
150SL 1.5" Nailstrip panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.5 Other: 168.5 psf @ 6" oc WITH sealant |
Installation Instructions FL29523_R4_II_32Al_150SL_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29523_R4_AE_32Al_150SL_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
29523.7 |
07: 150SL 1.5" Nailstrip 032 Aluminum HVHZ |
150SL 1.5" Nailstrip panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank | 19" coverage |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.1 Other: 168.1 psf @ 6" oc WITH sealant |
Installation Instructions FL29523_R4_II_32Al_150SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29523_R4_AE_32Al_150SL_plywood.pdf Created by Independent Third Party: Yes |
|
29523.8 |
08: 150SL 1.5" Nailstrip 24ga HVHZ |
150SL 1.5" Nailstrip panel from 24ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank | 19" coverage |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-112.5 Other: 112.5 @ 6" oc WITH sealant |
Installation Instructions FL29523_R4_II_24ga_150SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29523_R4_AE_24ga_150SL_plywood.pdf Created by Independent Third Party: Yes |
|
29523.9 |
09: 100SL 1.0" Nailstrip 26ga |
100SL 1" Nailstrip panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5 Other: See report for details. |
Installation Instructions FL29523_R4_II_26ga_100SL_plywood_im.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29523_R4_AE_26ga_100SL_plywood_im.pdf Created by Independent Third Party: Yes |
|
29523.10 |
10: 100SL 1" Nailstrip 032 Aluminum |
100SL 1" Nailstrip panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5 Other: See report for details. |
Installation Instructions FL29523_R4_II_32Al_100SL_plywood_im.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL29523_R4_AE_32Al_100SL_plywood_im.pdf Created by Independent Third Party: Yes |