Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL31795-R6
Application Type Revision
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Jeld-Wen
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls, OR 97601
(541) 850-2650
rfricks@jeldwen.com
 
Authorized Signature Rylee Fricks
rfricks@jeldwen.com
 
Technical Representative JELD-WEN Corporate Customer Service
Address/Phone/Email 3737 Lakeport Blvd.
Klamath Falls, OR 97601
(800) 535-3936
customerserviceagents@jeld-wen.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Windows
Subcategory Fixed
 
Compliance Method Certification Mark or Listing
 
Certification Agency National Accreditation & Management Institute
Validated By National Accreditation & Management Institute
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A4402011
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 12/12/2023
Date Validated 01/04/2024
Date Pending FBC Approval
Date Approved 01/07/2024
 
Summary of Products
FL # Model, Number or Name Description
31795.1 Auraline Composite Stationary Casement (O) 36" x 72"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-55
 Other:  
Certification Agency Certificate
 FL31795_R6_C_CAC_NI014584-R1.pdf
Quality Assurance Contract Expiration Date
 10/31/2029
Installation Instructions
 FL31795_R6_II_Auraline Composite Stationary Casement FBC Installs (36x72)_1-27-20.pdf
 Verified By: Joseph A. Reed 58920
 Created by Independent Third Party: Yes
Evaluation Reports
 FL31795_R6_AE_23091-5 Jeld Wen Auraline 36x72 Stationary Casement FBC.pdf
 Created by Independent Third Party: Yes
31795.2 Auraline Composite Stationary Casement (O) 72" x 72"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-40
 Other:  
Certification Agency Certificate
 FL31795_R6_C_CAC_NI014523-R2.pdf
Quality Assurance Contract Expiration Date
 09/30/2029
Installation Instructions
 FL31795_R6_II_Auraline Composite Stationary Casement FBC Installs (72x72)_1-27-20.pdf
 Verified By: Joseph A. Reed 58920
 Created by Independent Third Party: Yes
Evaluation Reports
 FL31795_R6_AE_23091-1-R1 Jeld Wen Auraline Stationary Casement Window Installation FBC.pdf
 Created by Independent Third Party: Yes
31795.3 Auraline Composite Stationary Casement (OO) 72" x 72"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-55
 Other:  
Certification Agency Certificate
 FL31795_R6_C_CAC_NI014882-R1.pdf
Quality Assurance Contract Expiration Date
 05/31/2030
Installation Instructions
 FL31795_R6_II_Auraline Composite Insash Stationary Casement_Two Wide_FBC_08-03-20.pdf
 Verified By: Joseph A. Reed 58920
 Created by Independent Third Party: Yes
Evaluation Reports
 FL31795_R6_AE_23492-1 Jeld Wen Auraline Stationary Casement CHS 2-wide FBC.pdf
 Created by Independent Third Party: Yes
31795.4 Auraline Composite Stationary Casement (OOOO) 144" x 72"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-55
 Other:  
Certification Agency Certificate
 FL31795_R6_C_CAC_NI014524.09 (002).pdf
Quality Assurance Contract Expiration Date
 06/30/2030
Installation Instructions
 FL31795_R6_II_Auraline Composite Insash Stationary Casement_Four Wide_FBC_08-03-20.pdf
 Verified By: Joseph A. Reed 58920
 Created by Independent Third Party: Yes
Evaluation Reports
 FL31795_R6_AE_23508-1 Jeld Wen Auraline Stationary Casement CHS 4-wide FBC.pdf
 Created by Independent Third Party: Yes
31795.5 Auraline Composite Stationary Casement (O) 84" x 84"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-40
 Other:  
Certification Agency Certificate
 FL31795_R6_C_CAC_NI015420 (1).pdf
Quality Assurance Contract Expiration Date
 06/30/2030
Installation Instructions
 FL31795_R6_II_D015608 - Auraline Composite Casement Fixed Insash 84 x 84 FBC Installs SEALED.pdf
 Verified By: Joseph A. Reed 58920
 Created by Independent Third Party: Yes
Evaluation Reports
 FL31795_R6_AE_24657-1 Jeld Wen Auraline Composite Casement Fixed Insash FBC.pdf
 Created by Independent Third Party: Yes
31795.6 Auraline Composite Fixed with Track Filler (O) 36" x 72"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-55
 Other:  
Certification Agency Certificate
 FL31795_R6_C_CAC_FL31992_R4_C_CAC_NI014524.07-R1.pdf
Quality Assurance Contract Expiration Date
 10/31/2029
Installation Instructions
 FL31795_R6_II_FL31992_R4_II_Auraline Side Load SH Fixed Track Filler Thru Jamb FBC Installs (32x72)_04-01-20 (1).pdf
 Verified By: Joseph A. Reed 58920
 Created by Independent Third Party: Yes
Evaluation Reports
 FL31795_R6_AE_FL31992_R4_AE_23125-1-R1 Jeld Wen Auraline Fixed with Track Filler FBC.pdf
 Created by Independent Third Party: Yes
31795.7 Auraline Composite Fixed with Track Filler (O) 72" x 72"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-40
 Other:  
Certification Agency Certificate
 FL31795_R6_C_CAC_FL31992_R4_C_CAC_NI014524.05-R1.pdf
 FL31795_R6_C_CAC_FL31992_R4_C_CAC_NI014524.06-R1.pdf
Quality Assurance Contract Expiration Date
 10/31/2029
Installation Instructions
 FL31795_R6_II_FL31992_R4_II_Auraline Side Load SH Fixed Track Filler Thru Jamb FBC Installs (72x72)_04-01-20.pdf
 Verified By: Joseph A. Reed 58920
 Created by Independent Third Party: Yes
Evaluation Reports
 FL31795_R6_AE_FL31992_R4_AE_23125-1-R1 Jeld Wen Auraline Fixed with Track Filler FBC.pdf
 Created by Independent Third Party: Yes
31795.8 Auraline Composite Fixed with Track Filler (O) 96" x 96"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-40
 Other:  
Certification Agency Certificate
 FL31795_R6_C_CAC_FL31992_R4_C_CAC_NI014524.12.pdf
Quality Assurance Contract Expiration Date
 12/31/2030
Installation Instructions
 FL31795_R6_II_FL31992_R4_II_Auraline Composite Fixed with Track Filler_FBC Installs (96x96)_12-17-20 SEALED.pdf
 Verified By: Joseph A. Reed 58920
 Created by Independent Third Party: Yes
Evaluation Reports
 FL31795_R6_AE_FL31992_R4_AE_23901-1 Jeld Wen Auraline FW with Track Filler FBC.pdf
 Created by Independent Third Party: Yes
31795.9 Auraline Composite Fixed with Track Filler (OOO) 144" x 72"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-40
 Other:  
Certification Agency Certificate
 FL31795_R6_C_CAC_FL31992_R4_C_CAC_NI014524.11.pdf
Quality Assurance Contract Expiration Date
 12/31/2030
Installation Instructions
 FL31795_R6_II_FL31992_R4_II_Auraline Composite Fixed with Track Filler Mullion (CHS)_3 Wide_FBC_08-27-20.pdf
 Verified By: Joseph A. Reed 58920
 Created by Independent Third Party: Yes
Evaluation Reports
 FL31795_R6_AE_FL31992_R4_AE_23617-1 Jeld Wen Auraline 3-Wide FW Track Filler Mullion FBC.pdf
 Created by Independent Third Party: Yes
31795.10 Auraline Composite Single Hung Fixed 3 High CHS (OOO) 120" x 84"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-40
 Other:  
Certification Agency Certificate
 FL31795_R6_C_CAC_FL31992_R4_C_CAC_NI014524.23_OOO_PG35_120x84_DP-40.pdf
Quality Assurance Contract Expiration Date
 05/31/2030
Installation Instructions
 FL31795_R6_II_FL31992_R4_II_D015732 - AC SH Fixed DS CHS (OOO) 120x84 DP35-40 FBC Installs_6-15-22 SEALED.pdf
 Verified By: Joseph A. Reed 58920
 Created by Independent Third Party: Yes
Evaluation Reports
 FL31795_R6_AE_FL31992_R4_AE_25269-1 Jeld Wen Auraline SH Fixed CHS 3-Wide FBC.pdf
 Created by Independent Third Party: Yes
31795.11 Auraline Composite Fixed (O) 72x72
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-55
 Other:  
Certification Agency Certificate
 FL31795_R6_C_CAC_FL32018_R3_C_CAC_NI014524.04-R2.pdf
Quality Assurance Contract Expiration Date
 09/30/2029
Installation Instructions
 FL31795_R6_II_FL32018_R3_II_Auraline Composite Fixed FBC Installs (72x72-DP50)_04-06-20 (1).pdf
 Verified By: Joseph A. Reed 58920
 Created by Independent Third Party: Yes
Evaluation Reports
 FL31795_R6_AE_FL32018_R3_AE_23122-1-R1 Jeld Wen Auraline Composite Fixed FBC.pdf
 Created by Independent Third Party: Yes
31795.12 Auraline Composite Fixed (O) 96" x 96"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-40
 Other:  
Certification Agency Certificate
 FL31795_R6_C_CAC_FL32018_R3_C_CAC_NI014524.03-R2.pdf
Quality Assurance Contract Expiration Date
 09/30/2029
Installation Instructions
 FL31795_R6_II_FL32018_R3_II_Auraline Composite Fixed FBC Installs (96x96)_04-06-20.pdf
 Verified By: Joseph A. Reed 58920
 Created by Independent Third Party: Yes
Evaluation Reports
 FL31795_R6_AE_FL32018_R3_AE_23122-1-R1 Jeld Wen Auraline Composite Fixed FBC.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 