7993.1 |
1-Course 14" exposure Mansard Panel |
Single course, 14-inch exposure vertical grain, 3/8-inch thick butt Mansard siding panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +52.6/-0.0 Other: ASTM E330 max test PSF =(228.8 PSF) / (2.5 SF) = 91.5 PSF |
Installation Instructions FL7993_R0_II_CedarValley_1-C 14-inch_Installation_instructions.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL7993_R0_AE_CedarValley_ICCReport_94116C.pdf |
|
7993.2 |
1-Course 5.3" exposure Coastal Panel |
Single course, 5.3-inch exposure Vertical grain, 5/16-inch thick butt shingle siding panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +98.4/-0.0 Other: ASTM E330 max test PSF= (245.
9 PSF) / (2.5SF) = 98.4 PSF |
Installation Instructions FL7993_R0_II_CedarValley_1-C_Coastal-VentPanel_Installation_instructions.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL7993_R0_AE_CedarValley_ICCReport_94116C.pdf |
|
7993.3 |
1-Course 7 1/8" exposure Coastal Panel |
Single course, 7 1/8-inch esposure, vertical grain 5/16-inch thick butt shingle siding panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +79.0/-0.0 Other: ASTM E330 max test PSF= (197.
6 PSF) / (2.5SF) = 79.0 PSF |
Installation Instructions FL7993_R0_II_CedarValley_1-C_Coastal-VentPanel_Installation_instructions.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL7993_R0_AE_CedarValley_ICCReport_94116C.pdf |
|
7993.4 |
1-Course 7 1/8" exposure Vent Panel |
Single course, 7 1/8"-inch exposure, vertical grain, 5/16-inch thick butt shingle, with 5/16-inch thick X 3/4-inch wide by 6 1/2-inch long wood strips, applied to back 8-inches O.C. (On Center) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +99.8/-0.0 Other: ASTM E330 max test PSF =(249.6 PSF) / (2.5 SF) = 99.8 PSF |
Installation Instructions FL7993_R0_II_CedarValley_1-C_Coastal-VentPanel_Installation_instructions.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL7993_R0_AE_CedarValley_ICCReport_94116C.pdf |
|
7993.5 |
1-Course MG 5.3" exp 1/2" T/B Coastal Panel |
Single course, 5.3-inch exposure mixed grain, 1/2-inch thick butt shingle sideing panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +99.8/-0.0 Other: ASTM E330 max test PSF =(249.6 PSF) / (2.5 SF) = 99.8 PSF |
Installation Instructions FL7993_R0_II_CedarValley_1-C_Coastal-VentPanel_Installation_instructions.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL7993_R0_AE_CedarValley_ICCReport_94116C.pdf |