13447.1 |
Senergy Senerflex Channeled Adhesive Design |
Senergy Senerflex Channeled Adhesive Design installed over plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +75/-75 Other: |
Certification Agency Certificate FL13447_R2_C_CAC_13-071703 Ch Adh Plywood.pdf Quality Assurance Contract Expiration Date 10/02/2018 Installation Instructions FL13447_R2_II_13-071703 Ch Adh Plywood.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13447.2 |
Senergy Senerflex Channeled Adhesive Design |
Senergy Senerflex Channeled Adhesive Design on gypsum sheathing and steel studs, large missile impact |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Design pressure +/- 60 on 18 ga steel studs, +/- 30 on 20 ga steel studs |
Certification Agency Certificate FL13447_R2_C_CAC_13-071704 Ch Adh DGG GlasRoc Securock LMI.pdf Quality Assurance Contract Expiration Date 09/18/2018 Installation Instructions FL13447_R2_II_13-071704 Ch Adh DGG GlasRoc Securock LMI.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13447.3 |
Senergy Senerflex Channeled Adhesive Design |
Senergy Senerflex Channeled Adhesive Design on gypsum sheathing and steel studs, small missile impact |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Design pressure +/- 60 on 18 ga steel studs, +/- 30 on 20 ga steel studs |
Certification Agency Certificate FL13447_R2_C_CAC_13-071706 Ch Adh DGG GlasRoc Securock SMI.pdf Quality Assurance Contract Expiration Date 09/18/2018 Installation Instructions FL13447_R2_II_13-071706 Ch Adh DGG GlasRoc Securock SMI.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13447.4 |
Senergy Senerflex Classic PB |
Senergy Senerflex Classic PB installed over CMU |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +125/-125 Other: |
Certification Agency Certificate FL13447_R2_C_CAC_13-071702 Sflex on CMU.pdf Quality Assurance Contract Expiration Date 09/25/2018 Installation Instructions FL13447_R2_II_13-071702 Sflex on CMU.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13447.5 |
Senergy Senerflex Classic PB |
Senergy Senerflex Classic PB on gypsum sheathing and steel studs, large missile impact |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Design pressure +/- 60 on 18 ga steel studs, +/- 30 on 20 ga steel studs |
Certification Agency Certificate FL13447_R2_C_CAC_13-071707 Sflex DGG GlasRoc Securock LMI.pdf Quality Assurance Contract Expiration Date 09/25/2018 Installation Instructions FL13447_R2_II_13-071707 Sflex DGG GlasRoc Securock LMI.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13447.6 |
Senergy Senerflex Classic PB |
Senergy Senerflex Classic PB on gypsum sheathing and steel studs, small missile impact |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Design pressure +/- 60 on 18 ga steel studs, +/- 30 on 20 ga steel studs |
Certification Agency Certificate FL13447_R2_C_CAC_13-071708 Sflex DGG GlasRoc Securock SMI.pdf Quality Assurance Contract Expiration Date 10/02/2018 Installation Instructions FL13447_R2_II_13-071708 Sflex DGG GlasRoc Securock SMI.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
13447.7 |
Senergy Senerflex Classic PB |
Senergy Senerflex Classic PB on reinforced gypsum sheathing and steel studs, large missile impact |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: |
Certification Agency Certificate FL13447_R2_C_CAC_13-071705 Sflex 12 oz on DGG Securock LMI.pdf Quality Assurance Contract Expiration Date 09/18/2018 Installation Instructions FL13447_R2_II_13-071705 Sflex 12 oz on DGG Securock LMI.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |