23953.1 |
2.67" x 7/8" Corrugated Panels |
24 Gage Steel and .032" Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: ASTM 1592-01 Tested Loads open framing with 2.0 Safety Factors: 24 Gage Steel: 5'0"= -78.6 PSF 2'0"= -159.8 PSF .032" Aluminum: 5'0"=-47.1 PSF 2.0"= -156.4 PSF |
Installation Instructions FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf Created by Independent Third Party: Yes |
|
23953.2 |
7.2" Rib Panel |
24 Gage Steel .032" Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: ASTM 1592 Tested Loads open framing: 24 Gage Steel: 5'0"=-78.8 PSF, 2'0"= -159.7 PSF, .032" Aluminum: 5'0"= -61.1 PSF 2'0"= -104.0 PSF |
Installation Instructions FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf Created by Independent Third Party: Yes |
|
23953.3 |
Edge-Loc 1.0 (.032" min.) |
.032" Aluminum over 1/2" min. Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: The use of a Class "A" fire barrier is not required outside the HVHZ unless otherwise specified in the building code. Design pressure includes a safety factor=2:0. Fasteners to be corrosion resistant. All materials and installation to be in compliance with FBC (2014) 5th Edition. |
Installation Instructions FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf Created by Independent Third Party: Yes |
|
23953.4 |
Large Precision Tile Panel: Aluminum |
14.5" wide x .032" (min) aluminum Large Precision Tile Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-202 Other: |
Installation Instructions FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf Created by Independent Third Party: Yes |
|
23953.5 |
Large Precision Tile Panel: Steel |
14.5" wide x 24 ga. (min) steel Large Precision Tile Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-248 Other: |
Installation Instructions FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf Created by Independent Third Party: Yes |
|
23953.6 |
M-36 panel x 36" wide |
24 Ga. Steel (min.) and .032" Aluminum (min.) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: ASTM E-1592 over open framing | 24 Ga. (min.) Steel Panels: 1' @ -120 PSF and 5' @ -80 PSF | .032" (min.) Aluminum Panels: 1' @ -107 PSF and 5' @ -70 PSF... see load tables for more available spans. |
Installation Instructions FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf Created by Independent Third Party: Yes |
|
23953.7 |
Precision Diamond Tile Panel: Aluminum |
7.25" wide x .032" (min) aluminum Precision Diamond Tile Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-217 Other: |
Installation Instructions FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf Created by Independent Third Party: Yes |
|
23953.8 |
Precision Diamond Tile Panel: Steel |
7.25" wide x 24 ga. (min) steel Precision Diamond Tile Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-243 Other: |
Installation Instructions FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf Created by Independent Third Party: Yes |
|
23953.9 |
R-36 panel x 36" wide |
24 Ga. Steel, 22 Ga. Steel, .032" Aluminum, and .040" Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: ASTM E-1592 over open framing | 24 Ga. Steel Panels: 2'0" @ -159.1 PSF and 5'0" @ -49.5 PSF | 22 Gage Steel Panels: 2'0" @ -154.1 PSF and 5'0" @ -52.8 PSF | .032" Aluminum Panels: 2'0" @ -143.2 PSF and 5'0" @ -28.0 PSF | .040" Aluminum Panels: 2'0" @ -156.3 PSF and 5'0" @ -49.7 PSF... see load tables for more available spans. |
Installation Instructions FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf Created by Independent Third Party: Yes |
|
23953.10 |
SNAP-CLAD 16 Oz Copper |
Standing Seam Roof Panels 16" wide by 1 3/4" high with Concealed Stainless Steel Clips and Fasteners to Structural Support on a Full Structural Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: Panel clip spacing not to exceed 24" o.c. with two #10-16 X 1" long pancake head stainless steel screws per clip. Plywood decking 19/32" thick, grade B-C, exposure 1, APA rated sheathing (42/20) square edged, with all joints sealed with caulk or a one part urethane sealant. |
Installation Instructions FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf Created by Independent Third Party: Yes |
|
23953.11 |
Snap-On Standing Seam Panel |
Standing Seam Roof Panels with Concealed Clips and Fasteners to Structural Support on Full Deck; With Snap-On Batten Cap over Clips and 1" High Legs. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Not for use in HVHZ pending further testing for cyclic wind loading performance. An experienced and licensed designer should determine wind zone pressures, with appropriate adjustment factors to determine adequate application of this product to meet Florida requirements.
24 Gage Steel: 1'-0"o.c. = 41.6 PSF
.032" Aluminum: 1'-0"o.c. = 41.3 PSF |
Installation Instructions FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf Created by Independent Third Party: Yes |
|
23953.12 |
TITE-LOC PLUS |
.040" Aluminum x 12" wide panel and .040" Aluminum x 16" wide panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-152.1 Other: 12" wide panel: 24" clip spacing: -107.9 12" clip spacing: -146.9 6" clip spacing: -152.1 16" wide panel: 24" clip spacing: -76.7 12" clip spacing: -87.15 6" clip spacing: -105.3 |
Installation Instructions FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf Created by Independent Third Party: Yes |
|
23953.13 |
Tite-Loc Plus |
12" Wide x 0.040" Aluminum Panel over 22 Ga. Metal B-Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-160.95 Other: Uplift load of 52.5 psf @ clip spacing of 48" o.c. and 160.95 psf @ clip spacing of 12" o.c. Install per manufacturer's details. Not for use in HVHZ. |
Installation Instructions FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf Created by Independent Third Party: Yes |
|
23953.14 |
Tite-Loc Plus |
12" Wide x 22 Ga. Steel Panels over 22 Ga. Metal B-Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-186.4 Other: Uplift load of 56.0 psf @ clip spacing of 48" o.c. and 186.4 psf @ clip spacing of 6" o.c. Install per manufacturer's details. Not for use in HVHZ. |
Installation Instructions FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf Created by Independent Third Party: Yes |
|
23953.15 |
Tite-Loc Plus |
18" Wide x 24 Ga. Steel Panels over 22 Ga. Metal B-Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 Other: Uplift load of 30.0 psf @ clip spacing of 48" o.c. and 78.5 psf @ clip spacing of 6" o.c. Install per manufacturer's details. Not for use in HVHZ. |
Installation Instructions FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf Created by Independent Third Party: Yes |
|
23953.16 |
Tite-Loc Plus |
16" Wide x 0.032" Aluminum Panels over min. 19/32" Plywood Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-74.1 Other: Uplift load of 61.1 psf @ clip spacing of 24" o.c. and 74.1 psf @ clip spacing of 12" o.c. Install per manufacturer's details. Not for use in HVHZ. |
Installation Instructions FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf Created by Independent Third Party: Yes |