Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL23953
Application Type New
Code Version 2017
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Petersen Aluminum Corp.
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(954) 461-7055
ndelfino@petersenmail.com
 
Authorized Signature Sal Delfino
sdelfino@petersenmail.com
 
Technical Representative Sal Delfino
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(954) 931-1392
sdelfino@petersenmail.com
 
Quality Assurance Representative Tom Creigh, VP
Address/Phone/Email Petersen Aluminum, Inc.
1005 Tonne Road
Elk Grove, IL 60007
(800) 722-7150
tcreigh@petersenmail.com
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Locke Bowden
Florida License PE-49704
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 09/11/2022
Validated By Zachary R. Priest, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL23953_R0_COI_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E 15922005
TAS 1252003
UL 18972012
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/16/2017
Date Validated 10/29/2017
Date Pending FBC Approval 10/30/2017
Date Approved 12/12/2017
 
Summary of Products
FL # Model, Number or Name Description
23953.1 2.67" x 7/8" Corrugated Panels 24 Gage Steel and .032" Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: ASTM 1592-01 Tested Loads open framing with 2.0 Safety Factors: 24 Gage Steel: 5'0"= -78.6 PSF 2'0"= -159.8 PSF .032" Aluminum: 5'0"=-47.1 PSF 2.0"= -156.4 PSF
Installation Instructions
 FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 Created by Independent Third Party: Yes
23953.2 7.2" Rib Panel 24 Gage Steel .032" Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: ASTM 1592 Tested Loads open framing: 24 Gage Steel: 5'0"=-78.8 PSF, 2'0"= -159.7 PSF, .032" Aluminum: 5'0"= -61.1 PSF 2'0"= -104.0 PSF
Installation Instructions
 FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 Created by Independent Third Party: Yes
23953.3 Edge-Loc 1.0 (.032" min.) .032" Aluminum over 1/2" min. Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5
 Other: The use of a Class "A" fire barrier is not required outside the HVHZ unless otherwise specified in the building code. Design pressure includes a safety factor=2:0. Fasteners to be corrosion resistant. All materials and installation to be in compliance with FBC (2014) 5th Edition.
Installation Instructions
 FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 Created by Independent Third Party: Yes
23953.4 Large Precision Tile Panel: Aluminum 14.5" wide x .032" (min) aluminum Large Precision Tile Panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-202
 Other:  
Installation Instructions
 FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 Created by Independent Third Party: Yes
23953.5 Large Precision Tile Panel: Steel 14.5" wide x 24 ga. (min) steel Large Precision Tile Panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-248
 Other:  
Installation Instructions
 FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 Created by Independent Third Party: Yes
23953.6 M-36 panel x 36" wide 24 Ga. Steel (min.) and .032" Aluminum (min.)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: ASTM E-1592 over open framing | 24 Ga. (min.) Steel Panels: 1' @ -120 PSF and 5' @ -80 PSF | .032" (min.) Aluminum Panels: 1' @ -107 PSF and 5' @ -70 PSF... see load tables for more available spans.
Installation Instructions
 FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 Created by Independent Third Party: Yes
23953.7 Precision Diamond Tile Panel: Aluminum 7.25" wide x .032" (min) aluminum Precision Diamond Tile Panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-217
 Other:  
Installation Instructions
 FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 Created by Independent Third Party: Yes
23953.8 Precision Diamond Tile Panel: Steel 7.25" wide x 24 ga. (min) steel Precision Diamond Tile Panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-243
 Other:  
Installation Instructions
 FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 Created by Independent Third Party: Yes
23953.9 R-36 panel x 36" wide 24 Ga. Steel, 22 Ga. Steel, .032" Aluminum, and .040" Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: ASTM E-1592 over open framing | 24 Ga. Steel Panels: 2'0" @ -159.1 PSF and 5'0" @ -49.5 PSF | 22 Gage Steel Panels: 2'0" @ -154.1 PSF and 5'0" @ -52.8 PSF | .032" Aluminum Panels: 2'0" @ -143.2 PSF and 5'0" @ -28.0 PSF | .040" Aluminum Panels: 2'0" @ -156.3 PSF and 5'0" @ -49.7 PSF... see load tables for more available spans.
Installation Instructions
 FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 Created by Independent Third Party: Yes
23953.10 SNAP-CLAD 16 Oz Copper Standing Seam Roof Panels 16" wide by 1 3/4" high with Concealed Stainless Steel Clips and Fasteners to Structural Support on a Full Structural Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5
 Other:  Panel clip spacing not to exceed 24" o.c. with two #10-16 X 1" long pancake head stainless steel screws per clip. Plywood decking 19/32" thick, grade B-C, exposure 1, APA rated sheathing (42/20) square edged, with all joints sealed with caulk or a one part urethane sealant.
Installation Instructions
 FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 Created by Independent Third Party: Yes
23953.11 Snap-On Standing Seam Panel Standing Seam Roof Panels with Concealed Clips and Fasteners to Structural Support on Full Deck; With Snap-On Batten Cap over Clips and 1" High Legs.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: Not for use in HVHZ pending further testing for cyclic wind loading performance. An experienced and licensed designer should determine wind zone pressures, with appropriate adjustment factors to determine adequate application of this product to meet Florida requirements. 24 Gage Steel: 1'-0"o.c. = 41.6 PSF .032" Aluminum: 1'-0"o.c. = 41.3 PSF
Installation Instructions
 FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 Created by Independent Third Party: Yes
23953.12 TITE-LOC PLUS .040" Aluminum x 12" wide panel and .040" Aluminum x 16" wide panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-152.1
 Other: 12" wide panel: 24" clip spacing: -107.9 12" clip spacing: -146.9 6" clip spacing: -152.1 16" wide panel: 24" clip spacing: -76.7 12" clip spacing: -87.15 6" clip spacing: -105.3
Installation Instructions
 FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 Created by Independent Third Party: Yes
23953.13 Tite-Loc Plus 12" Wide x 0.040" Aluminum Panel over 22 Ga. Metal B-Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-160.95
 Other: Uplift load of 52.5 psf @ clip spacing of 48" o.c. and 160.95 psf @ clip spacing of 12" o.c. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 Created by Independent Third Party: Yes
23953.14 Tite-Loc Plus 12" Wide x 22 Ga. Steel Panels over 22 Ga. Metal B-Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-186.4
 Other: Uplift load of 56.0 psf @ clip spacing of 48" o.c. and 186.4 psf @ clip spacing of 6" o.c. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 Created by Independent Third Party: Yes
23953.15 Tite-Loc Plus 18" Wide x 24 Ga. Steel Panels over 22 Ga. Metal B-Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-78.5
 Other: Uplift load of 30.0 psf @ clip spacing of 48" o.c. and 78.5 psf @ clip spacing of 6" o.c. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 Created by Independent Third Party: Yes
23953.16 Tite-Loc Plus 16" Wide x 0.032" Aluminum Panels over min. 19/32" Plywood Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-74.1
 Other: Uplift load of 61.1 psf @ clip spacing of 24" o.c. and 74.1 psf @ clip spacing of 12" o.c. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL23953_R0_II_FL 23953 Petersen Aluminum Detail Binder SS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23953_R0_AE_FL 23953 PETERSEN ALUM REPORT complete-SS.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe