6393.1 |
VELUX Flat Glass Sun Tunnel (HVHZ) |
[TZR or TZRL or TZRQ] + [014] + [1A00] 3.9mm tempered clear outer pane with 7mm laminated inner pane. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +120/-80 Other: Wind Zone 4, Missile D, Cycle Pressure +50/-50; Max tube dia. 356 mm (14 in). Tested for cycling per ASTM E1886/ASTM E1996. Glass meets ASTM E1300: 3.9mm tempered clear outer pane with 7mm laminate using 2.3mm panes and three 0.030" PVB interlayers. Anchorage fasteners provided to secure skylight to curb : #8 1 3/4" (4.2 x 45mm) pan head st. st. metal screws. |
Certification Agency Certificate FL6393_R19_C_CAC_FL6393 TZR_TZRL_TZRQ (impact) 014 1A00.pdf Quality Assurance Contract Expiration Date 02/23/2031 Installation Instructions FL6393_R19_II_TZR-TZRL-TZRQ Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.2 |
VELUX Flat Glass Sun Tunnel (Non-Impact) |
[TZR or TZRL or TZRQ] + [014] + [2A00] 3mm tempered LowE366 outer pane with 7mm diamond wire inner pane. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +140/-140 Other: SKG-PG140; Max tube dia. 356 mm (14 in). PG140 means minimum capacity is 140 psf. Glazing assembly is 3mm tempered LowE366 outer pane with 7mm diamond wire inner pane. Anchorage fasteners provided to secure skylight to curb : #8 1 3/4" (4.2 x 45mm) pan head st. st. metal screws |
Certification Agency Certificate FL6393_R19_C_CAC_FL6393 TZR_TZRL_TZRQ (non-impact) 014 2A00.pdf Quality Assurance Contract Expiration Date 03/05/2031 Installation Instructions FL6393_R19_II_TZR-TZRL-TZRQ Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.3 |
VELUX Sun Tunnel TSR 0000 |
TSR 010 size (426-H-626.07) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +200/-180 Other: TDDCC-PG180; Size tested 254 mm dia (10 in). PG180 means minimum capacity is 180 psf. Dome glazing is minimum 3mm thick. Flashing nails directly to roof deck. Anchorage fasteners provided are 10 ga. galv. ring shank nails. |
Certification Agency Certificate FL6393_R19_C_CAC_426-H-626.07.pdf Quality Assurance Contract Expiration Date 04/03/2027 Installation Instructions FL6393_R19_II_TSR_010_Installation.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.4 |
VELUX Sun Tunnel TLR (Tempered Glass) |
TLR 014 + [2000A or 2000AE1] (426-H-693.02) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +150/-245 Other: TDDCC-PG150; Max. tube dia. 356 mm (14 in) - TDD. PG150 means minimum capacity is 150 psf. Exterior glazing is minimum 4mm thick clear tempered glass meeting ASTM E1300. Anchorage fasteners provided: 2.2 mm x 3/4" ring shank nails for alignment on top of roof deck, and #6 pan head sheet metal screws for clamping on underside of deck. |
Certification Agency Certificate FL6393_R19_C_CAC_426-H-693.02.pdf Quality Assurance Contract Expiration Date 10/03/2025 Installation Instructions FL6393_R19_II_TLR_014_Installation.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.5 |
VELUX TCC 022 (Curb Mount) Commercial Sun Tunnel - Impact Resistant |
TCC 022 + 5000 (426-H-708.04) Polycarb Dome. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +300/-160 Other: Wind Zone 3, Missile C, Cycle Pressure +50/-50; Tested for cycling per ASTM E1886/ASTM E1996. TDDOC/TDDCC-PG160; Max. tube dia. 559 mm (22 in) - TDD. PG160 means minimum capacity is 160 psf. Dome glazing is minimum 3 mm thick. Flashing attaches to curb. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R19_C_CAC_TCC 022 5000 (Impact) CCL.pdf Quality Assurance Contract Expiration Date 10/22/2031 Installation Instructions FL6393_R19_II_TCC Installation Instructions.pdf FL6393_R19_II_THC_Diffuser_Installation Instructions.pdf FL6393_R19_II_TOC_Diffuser_Installation Instructions.pdf FL6393_R19_II_TTC_Diffuser_Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.6 |
VELUX TCC 022 (Curb Mount) Commercial Sun Tunnel - Non-Impact |
TCC 022 + 3000 (426-H-708.10/.11) Acrylic Dome. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +300/-160 Other: TDDOC/TDDCC-PG160; Max. tube dia. 559 mm (22 in) - TDD. PG160 means minimum capacity is 160 psf. Dome glazing is minimum 3 mm thick. Flashing attaches to curb. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R19_C_CAC_TCC 022 3000 (Non-Impact) CCL.pdf Quality Assurance Contract Expiration Date 01/04/2032 Installation Instructions FL6393_R19_II_TCC Installation Instructions.pdf FL6393_R19_II_THC_Diffuser_Installation Instructions.pdf FL6393_R19_II_TOC_Diffuser_Installation Instructions.pdf FL6393_R19_II_TTC_Diffuser_Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.7 |
VELUX TCR/TCC 014 (Curb Mount) Sun Tunnel - Impact Resistant |
TCR/TCC 014 + 1000 (426-H-706.08) Polycarb Dome |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +300/-165 Other: Wind Zone 3, Missile C, Cycle Pressure +50/-50; Tested for cycling per ASTM E1886/ASTM E1996. TDDCC-PG165; Max. tube dia. 356 mm (14 in) - TDD. PG165 means minimum capacity is 165 psf. Dome glazing is minimum 3 mm thick. Flashing attaches to curb. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R19_C_CAC_TCR-TCC 014 1000 (Impact) CCL.pdf Quality Assurance Contract Expiration Date 09/24/2031 Installation Instructions FL6393_R19_II_TCC Installation Instructions.pdf FL6393_R19_II_TCR Installation Instructions.pdf FL6393_R19_II_THC_Diffuser_Installation Instructions.pdf FL6393_R19_II_TOC_Diffuser_Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.8 |
VELUX TCR/TCC 014 (Curb Mount) Sun Tunnel - Non-Impact |
TCR/TCC 014 + 0000 (426-H-706.04/.05) Acrylic Dome |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +300/-165 Other: TDDCC-PG165; Max. tube dia. 356 mm (14 in) - TDD. PG165 means minimum capacity is 165 psf. Dome glazing is minimum 3 mm thick. Flashing attaches to curb. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R19_C_CAC_TCR-TCC 014 0000 (Non-Impact) CCL.pdf Quality Assurance Contract Expiration Date 09/24/2031 Installation Instructions FL6393_R19_II_TCC Installation Instructions.pdf FL6393_R19_II_TCR Installation Instructions.pdf FL6393_R19_II_THC_Diffuser_Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.9 |
VELUX TGC 022 (Deck Mount) Commercial Sun Tunnel - Impact Resistant |
TGC 022 + 5000 (426-H-708.05) Polycarb Dome. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +300/-160 Other: Wind Zone 3, Missile C, Cycle Pressure +70/-70; Tested for cycling per ASTM E1886/ASTM E1996. TDDOC/TDDCC-PG160; Max. tube dia. 559 mm (22 in) - TDD. PG160 means minimum capacity is 160 psf. Dome glazing is minimum 3 mm thick. Flashing attaches to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R19_C_CAC_TGC 022 5000 (Impact) CCL.pdf Quality Assurance Contract Expiration Date 01/18/2032 Installation Instructions FL6393_R19_II_TGC Installation Instructions.pdf FL6393_R19_II_THC_Diffuser_Installation Instructions.pdf FL6393_R19_II_TOC_Diffuser_Installation Instructions.pdf FL6393_R19_II_TTC_Diffuser_Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.10 |
VELUX TGC 022 (Deck Mount) Commercial Sun Tunnel - Non-Impact |
TGC 022 + 3000 (426-H-708.06/.07) Acrylic Dome. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +300/-160 Other: TDDOC/TDDCC-PG160; Max. tube dia. 559 mm (22 in) - TDD. PG160 means minimum capacity is 160 psf. Dome glazing is minimum 3 mm thick. Flashing attaches to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R19_C_CAC_TGC 022 3000 (Non-Impact) CCL.pdf Quality Assurance Contract Expiration Date 01/18/2032 Installation Instructions FL6393_R19_II_TGC Installation Instructions.pdf FL6393_R19_II_THC_Diffuser_Installation Instructions.pdf FL6393_R19_II_TOC_Diffuser_Installation Instructions.pdf FL6393_R19_II_TTC_Diffuser_Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.11 |
VELUX TGF 014 (Deck Mount) Sun Tunnel - Impact Resistant |
TGF 014 + 1000 (426-H-705.05) Polycarb dome. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +300/-160 Other: Wind Zone 3, Missile C, Cycle Pressure +50/-50; Tested for cycling per ASTM E1886/ASTM E1996.
TDDCC-PG160; Max. tube dia. 356 mm (14 in) - TDD. PG160 means minimum capacity is 160 psf. Dome glazing is minimum 3 mm thick. Flashing attaches to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R19_C_CAC_TGF 014 1000 (Impact) CCL.pdf Quality Assurance Contract Expiration Date 09/28/2031 Installation Instructions FL6393_R19_II_TGF-TMF 014_Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.12 |
VELUX TGF 014 (Deck Mount) Sun Tunnel - Non-Impact |
TGF 014 + 0000 (426-H-705.11/.12) Acrylic dome. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +300/-160 Other: TDDCC-PG160; Max. tube dia. 356 mm (14 in) - TDD. PG160 means minimum capacity is 160 psf. Dome glazing is minimum 3 mm thick. Flashing attaches to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R19_C_CAC_TGF 014 0000 (Non-Impact) CCL.pdf Quality Assurance Contract Expiration Date 01/12/2032 Installation Instructions FL6393_R19_II_TGF-TMF 014_Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.13 |
VELUX TGF 022 (Deck Mount) Sun Tunnel - Impact Resistant |
TGF 022 + 1000 (426-H-705.05) Polycarb dome. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +300/-130 Other: Wind Zone 3, Missile C, Cycle Pressure +50/-50; Tested for cycling per ASTM E1886/ASTM E1996. TDDCC-PG130; Max. tube dia. 559 mm (22 in) - TDD. PG130 means minimum capacity is 130 psf. Dome glazing is minimum 3 mm thick. Flashing attaches to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R19_C_CAC_TGF 022 1000 (Impact) CCL.pdf Quality Assurance Contract Expiration Date 09/28/2031 Installation Instructions FL6393_R19_II_TGF-TMF Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.14 |
VELUX TGF 022 (Deck Mount) Sun Tunnel - Non-Impact |
TGF 022 + 0000 (426-H-705.07/.08) Acrylic dome. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +300/-130 Other: TDDCC-PG130; Max. tube dia. 559 mm (22 in) - TDD. PG130 means minimum capacity is 130 psf. Dome glazing is minimum 3 mm thick. Flashing attaches to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R19_C_CAC_TGF 022 0000 (Non-Impact) CCL.pdf Quality Assurance Contract Expiration Date 01/10/2032 Installation Instructions FL6393_R19_II_TGF-TMF Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.15 |
VELUX TGR/TGC 010 & 014 (Deck Mount) Sun Tunnel - Impact Resistant |
TGR/TGC 010 or 014 + 1000 (426-H-705.06) Polycarb dome. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +300/-160 Other: Wind Zone 3, Missile C, Cycle Pressure +50/-50; Tested for cycling per ASTM E1886/ASTM E1996. TDDCC/TDDOC-PG160; Max. tube dia. 356 mm (14 in) - TDD. PG160 means minimum capacity is 160 psf. Dome glazing is minimum 3 mm thick. Flashing attaches to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R19_C_CAC_TGR-TGC 010 or 014 1000 (Impact) CCL.pdf Quality Assurance Contract Expiration Date 09/28/2031 Installation Instructions FL6393_R19_II_TGC Installation Instructions.pdf FL6393_R19_II_TGR-TMR-THR 014_Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.16 |
VELUX TGR/TGC 010 & 014 (Deck Mount) Sun Tunnel - Non-Impact |
TGR/TGC 010 or 014 + 0000 (426-H-705.15/.16) Acrylic dome. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +300/-160 Other: TDDCC/TDDOC-PG160; Max. tube dia. 356 mm (14 in) - TDD. PG160 means minimum capacity is 160 psf. Dome glazing is minimum 3 mm thick. Flashing attaches to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R19_C_CAC_TGR-TGC 010 or 014 0000 (Non-Impact) CCL.pdf Quality Assurance Contract Expiration Date 01/10/2032 Installation Instructions FL6393_R19_II_TGC Installation Instructions.pdf FL6393_R19_II_TGR-TMR-THR 014_Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.17 |
VELUX TMF/TMR/THR 010 & 014 (Deck Mount) Sun Tunnel - Impact Resistant |
TMF/TMR/THR 010 or 014 + 1000 (426-H-705.04) Polycarb dome. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +300/-165 Other: Wind Zone 3, Missile C, Cycle Pressure +50/-50; Tested for cycling per ASTM E1886/ASTM E1996. TDDCC-PG165; Max. tube dia. 356 mm (14 in) - TDD. PG165 means minimum capacity is 165 psf. Dome glazing is minimum 3 mm thick. Flashing attaches to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R19_C_CAC_TMF-TMR-THR 010 or 014 1000 (Impact) CCL.pdf Quality Assurance Contract Expiration Date 09/30/2031 Installation Instructions FL6393_R19_II_TGF-TMF Installation Instructions.pdf FL6393_R19_II_TGR-TMR-THR 014_Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6393.18 |
VELUX TMF/TMR/THR 010 & 014 (Deck Mount) Sun Tunnel - Non-Impact |
TMF/TMR/THR 010 or 014 + 0000 (426-H-705.19/.20) Acrylic dome. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +300/-165 Other: TDDCC-PG165; Max. tube dia. 356 mm (14 in) - TDD. PG165 means minimum capacity is 165 psf. Dome glazing is minimum 3 mm thick. Flashing attaches to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. |
Certification Agency Certificate FL6393_R19_C_CAC_TMF-TMR-THR 010 or 014 0000 (Non-Impact) CCL.pdf Quality Assurance Contract Expiration Date 01/26/2032 Installation Instructions FL6393_R19_II_TGF-TMF Installation Instructions.pdf FL6393_R19_II_TGR-TMR-THR 014_Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |