14784.1 |
Premium Vinyl (V-4500) |
Fixed with Track Filler 72" x 72" Annealed Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-55 Other: |
Certification Agency Certificate FL14784_R15_C_CAC_LC-PG50-72x72_DP-55_New1.pdf Quality Assurance Contract Expiration Date 05/20/2028 Installation Instructions FL14784_R15_II_Premium Vinyl Fixed with Track Filler Install Package FBC 72 x 72_01-21-....pdf Verified By: Alexis Spyrou 68101 Created by Independent Third Party: Yes Evaluation Reports FL14784_R15_AE_23985-9-R1 Jeld Wen Premium Vinyl Fixed Windows FBC.pdf Created by Independent Third Party: Yes |
|
14784.2 |
Premium Vinyl (V-4500) |
Stationary Insash Casement 36" x 72" Annealed Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-55 Other: |
Certification Agency Certificate FL14784_R15_C_CAC_LC_PG50-36x72_DP-55_New.pdf Quality Assurance Contract Expiration Date 10/29/2027 Installation Instructions FL14784_R15_II_PV Stationary Casement NF Install 36x72_5-12-15.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
14784.3 |
Premium Vinyl (V-4500) |
Fixed 72" x 72" Annealed Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: |
Certification Agency Certificate FL14784_R15_C_CAC_LC_PG50-72x72_FinandFinless_New.pdf Quality Assurance Contract Expiration Date 05/11/2026 Installation Instructions FL14784_R15_II_Premium Vinyl Fixed with Sloped Sill FBC Installs 72 x 72_01-21-21 SEALE....pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports FL14784_R15_AE_23985-9-R1 Jeld Wen Premium Vinyl Fixed Windows FBC.pdf Created by Independent Third Party: Yes |
|
14784.4 |
Premium Vinyl (V-4500) |
Stationary Direct Set Casement 60" x 72" Annealed Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-40 Other: |
Certification Agency Certificate FL14784_R15_C_CAC_LC_PG35-60x72_DP-40_New1.pdf Quality Assurance Contract Expiration Date 10/22/2027 Installation Instructions FL14784_R15_II_PV Direct Set Casement NF Install 60x72_5-12-15.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
14784.5 |
Premium Vinyl (V-4500) |
Stationary Direct Set Casement 36" x 72" Annealed Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-55 Other: |
Certification Agency Certificate FL14784_R15_C_CAC_LC_PG50-36x72_DP-55_New1.pdf Quality Assurance Contract Expiration Date 10/23/2027 Installation Instructions FL14784_R15_II_PV Direct Set Casement NF Install 36x72_5-12-15.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
14784.6 |
Premium Vinyl (V-4500) |
Stationary Insash Casement 60" x 72" Annealed Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-40 Other: |
Certification Agency Certificate FL14784_R15_C_CAC_LC-PG35-60x72_DP-40_New1.pdf Quality Assurance Contract Expiration Date 10/25/2027 Installation Instructions FL14784_R15_II_PV Stationary Casement Install NF FBC 60 x 72_12-8-17.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
14784.7 |
Premium Vinyl (V-4500) |
Four Wide Stationary Direct Set Casement (OOOO) 144" x 72" Annealed Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-55 Other: |
Certification Agency Certificate FL14784_R15_C_CAC_OOOO_LC-PG50-144x72_DP-55.pdf Quality Assurance Contract Expiration Date 02/24/2028 Installation Instructions FL14784_R15_II_Premium Vinyl Direct Set Casement OOOO Nailfin Install DP50 (144x72) (2).pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
14784.8 |
Premium Vinyl (V-4500) |
Four Wide Stationary Insash Casement (OOOO) 144" x 72" Annealed Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-55 Other: |
Certification Agency Certificate FL14784_R15_C_CAC_OOOO_LC-PG50-144x72_DP-55_New1.pdf Quality Assurance Contract Expiration Date 03/07/2028 Installation Instructions FL14784_R15_II_Premium Vinyl Stationary Casement OOOO DP-50 Install NF FBC 144 x 72_12-26-17_New2.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
14784.9 |
Premium Vinyl (V-4500) |
Fixed 60" x 60" Annealed Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-55 Other: |
Certification Agency Certificate FL14784_R15_C_CAC_LC-PG50-60x60_DP-55_New.pdf Quality Assurance Contract Expiration Date 02/16/2027 Installation Instructions FL14784_R15_II_Premium Vinyl Fixed Sloped Sill Installs FBC 60 x 60_9-5-17.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
14784.10 |
Premium Vinyl (V-4500) |
Three Wide Fixed With Track Filler (OOO) 108" x 72" Annealed Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-55 Other: |
Certification Agency Certificate FL14784_R15_C_CAC_OOO_LC-PG50-108x72_DP-55_New1.pdf Quality Assurance Contract Expiration Date 06/02/2028 Installation Instructions FL14784_R15_II_Fin Install.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
14784.11 |
Premium Vinyl (V-4500) |
Four Wide Stationary Direct Set Casement (OOOO) 144" x 72" Annealed Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-40 Other: |
Certification Agency Certificate FL14784_R15_C_CAC_OOOO_LC-PG35-144x72_DP-40.pdf Quality Assurance Contract Expiration Date 01/06/2028 Installation Instructions FL14784_R15_II_Premium Vinyl Direct Set Casement OOOO DP35 Install NF FBC 144x72_12-26-17.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
14784.12 |
Premium Vinyl (V-4500) |
Four Wide Stationary Insash Casement (OOOO) 144" x 72" Annealed Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-40 Other: |
Certification Agency Certificate FL14784_R15_C_CAC_OOOO_LC-PG35-144x72_DP-40_New.pdf Quality Assurance Contract Expiration Date 02/06/2028 Installation Instructions FL14784_R15_II_Premium Vinyl Stationary Casement OOOO DP-35 Install NF FBC 144 x 72_12-26-17.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
14784.13 |
Premium Vinyl (V-4500) |
Tilt Single Hung Fixed (O) 73" x 84" Annealed Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-40 Other: |
Certification Agency Certificate FL14784_R15_C_CAC_LC-PG35_O_73x84_DP-40_New.pdf Quality Assurance Contract Expiration Date 02/06/2027 Installation Instructions FL14784_R15_II_Premium Vinyl TSH Fixed FBC Installs (73x84)_4-21-21 SEALED.pdf Verified By: Joseph A. Reed 58920 Created by Independent Third Party: Yes Evaluation Reports FL14784_R15_AE_24234-1 Jeld Wen Premium Vinyl Tilt SH Fixed FBC.pdf Created by Independent Third Party: Yes |