FL # FL35396-R1
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Petersen Aluminum Corp.
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(954) 461-7055
ndelfino@petersenmail.com
 
Authorized Signature Sal Delfino
sdelfino@petersenmail.com
 
Technical Representative Sal Delfino
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(954) 931-1392
sdelfino@petersenmail.com
 
Quality Assurance Representative Nick Delfino
Address/Phone/Email 1500 N. University Drive
Suite 201-G
Coral Springs, FL 33071
(954) 461-7055
ndelfino@petersenmail.com
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Locke Bowden
Florida License PE-49704
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL35396_R1_COI_SS CERTIFICATE OF INDEPENDENCE.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E 15922005
TAS 1252003
UL 18972015
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/28/2023
Date Validated 09/01/2023
Date Pending FBC Approval 09/12/2023
Date Approved 12/13/2023
 
Summary of Products
FL # Model, Number or Name Description
35396.1 2.67" x 7/8" Corrugated Panels 24 Gage Steel and .032" Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: 24 Gage Steel: 5'0"= -78.6 PSF 2'0"= -159.8 PSF .032" Aluminum: 5'0"=-47.1 PSF 2.0"= -156.4 PSF
Installation Instructions
 FL35396_R1_II_SS FL 35396 INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL35396_R1_AE_R SS FL 35396 ALL REPORTS.pdf
 Created by Independent Third Party: Yes
35396.2 7.2" Rib Panel 24 Gage Steel and .032" Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: 24 Gage Steel: 5'0"=-78.8 PSF, 2'0"= -159.7 PSF, .032" Aluminum: 5'0"= -61.1 PSF 2'0"= -104.0 PSF
Installation Instructions
 FL35396_R1_II_SS FL 35396 INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL35396_R1_AE_R SS FL 35396 ALL REPORTS.pdf
 Created by Independent Third Party: Yes
35396.3 Edge-Loc 1.0 (.032" min.) .032" Aluminum over 1/2" min. Plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5
 Other: The use of a Class "A" fire barrier is not required outside the HVHZ unless otherwise specified in the building code.
Installation Instructions
 FL35396_R1_II_SS FL 35396 INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL35396_R1_AE_R SS FL 35396 ALL REPORTS.pdf
 Created by Independent Third Party: Yes
35396.4 Large Precision Tile Panel: Aluminum 14.5" wide x .032" (min) aluminum Large Precision Tile Panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-202
 Other:  
Installation Instructions
 FL35396_R1_II_SS FL 35396 INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL35396_R1_AE_R SS FL 35396 ALL REPORTS.pdf
 Created by Independent Third Party: Yes
35396.5 Large Precision Tile Panel: Steel 14.5" wide x 24 ga. (min) steel Large Precision Tile Panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-248
 Other:  
Installation Instructions
 FL35396_R1_II_SS FL 35396 INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL35396_R1_AE_R SS FL 35396 ALL REPORTS.pdf
 Created by Independent Third Party: Yes
35396.6 M-36 panel x 36" wide 24 Ga. Steel (min.) and .032" Aluminum (min.)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: 24 Ga. (min.) Steel Panels: 1' @ -120 PSF and 5' @ -80 PSF | .032" (min.) Aluminum Panels: 1' @ -107 PSF and 5' @ -70 PSF... see load tables for more available spans.
Installation Instructions
 FL35396_R1_II_SS FL 35396 INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL35396_R1_AE_R SS FL 35396 ALL REPORTS.pdf
 Created by Independent Third Party: Yes
35396.7 Precision Diamond Tile Panel: Aluminum 7.25" wide x .032" (min) aluminum Precision Diamond Tile Panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-217
 Other:  
Installation Instructions
 FL35396_R1_II_SS FL 35396 INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL35396_R1_AE_R SS FL 35396 ALL REPORTS.pdf
 Created by Independent Third Party: Yes
35396.8 Precision Diamond Tile Panel: Steel 7.25" wide x 24 ga. (min) steel Precision Diamond Tile Panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-243
 Other:  
Installation Instructions
 FL35396_R1_II_SS FL 35396 INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL35396_R1_AE_R SS FL 35396 ALL REPORTS.pdf
 Created by Independent Third Party: Yes
35396.9 R-36 panel x 36" wide 24 Ga. Steel, 22 Ga. Steel, .032" Aluminum, and .040" Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: 24 Ga. Steel Panels: 2'0" @ -159.1 PSF and 5'0" @ -49.5 PSF | 22 Gage Steel Panels: 2'0" @ -154.1 PSF and 5'0" @ -52.8 PSF | .032" Aluminum Panels: 2'0" @ -143.2 PSF and 5'0" @ -28.8 PSF | .040" Aluminum Panels: 2'0" @ -143.2 PSF and 5'0" @ -49.7 PSF... see load tables for more available spans.
Installation Instructions
 FL35396_R1_II_SS FL 35396 INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL35396_R1_AE_R SS FL 35396 ALL REPORTS.pdf
 Created by Independent Third Party: Yes
35396.10 SNAP-CLAD 16 Oz Copper Standing Seam Roof Panels 16" wide by 1 3/4" high with Concealed Stainless Steel Clips and Fasteners to Structural Support on a Full Structural Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5
 Other: Panel clip spacing not to exceed 24" o.c. with two #10-16 X 1" long pancake head stainless steel screws per clip. Plywood decking 19/32" thick, grade B-C, exposure 1, APA rated sheathing (42/20) square edged, with all joints sealed with caulk or a one part urethane sealant.
Installation Instructions
 FL35396_R1_II_SS FL 35396 INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL35396_R1_AE_R SS FL 35396 ALL REPORTS.pdf
 Created by Independent Third Party: Yes
35396.11 Snap-On Standing Seam Panel Standing Seam Roof Panels with Concealed Clips and Fasteners to Structural Support on Full Deck; With Snap-On Batten Cap over Clips and 1" High Legs.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: 24 Gage Steel: 1'-0"o.c. = 41.6 PSF .032" Aluminum: 1'-0"o.c. = 41.3 PSF
Installation Instructions
 FL35396_R1_II_SS FL 35396 INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL35396_R1_AE_R SS FL 35396 ALL REPORTS.pdf
 Created by Independent Third Party: Yes
35396.12 Tite-Loc Plus .040" Aluminum x 12" wide panel and .040" Aluminum x 16" wide panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-152.1
 Other: 12" wide panel: 24" clip spacing: -107.9 12" clip spacing: -146.9 6" clip spacing: -152.1 16" wide panel: 24" clip spacing: -76.7 12" clip spacing: -87.15 6" clip spacing: -105.3
Installation Instructions
 FL35396_R1_II_SS FL 35396 INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL35396_R1_AE_R SS FL 35396 ALL REPORTS.pdf
 Created by Independent Third Party: Yes
35396.13 Tite-Loc Plus 12" Wide x 0.040" Aluminum Panel over 22 Ga. Metal B-Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-160.95
 Other: Uplift load of 52.5 psf @ clip spacing of 48" o.c. and 160.95 psf @ clip spacing of 12" o.c.
Installation Instructions
 FL35396_R1_II_SS FL 35396 INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL35396_R1_AE_R SS FL 35396 ALL REPORTS.pdf
 Created by Independent Third Party: Yes
35396.14 Tite-Loc Plus 12" Wide x 22 Ga. Steel Panels over 22 Ga. Metal B-Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-186.4
 Other: Uplift load of 56.0 psf @ clip spacing of 48" o.c. and 186.4 psf @ clip spacing of 6" o.c.
Installation Instructions
 FL35396_R1_II_SS FL 35396 INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL35396_R1_AE_R SS FL 35396 ALL REPORTS.pdf
 Created by Independent Third Party: Yes
35396.15 Tite-Loc Plus 18" Wide x 24 Ga. Steel Panels over 22 Ga. Metal B-Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-78.5
 Other: Uplift load of 30.0 psf @ clip spacing of 48" o.c. and 78.5 psf @ clip spacing of 6" o.c.
Installation Instructions
 FL35396_R1_II_SS FL 35396 INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL35396_R1_AE_R SS FL 35396 ALL REPORTS.pdf
 Created by Independent Third Party: Yes
35396.16 Tite-Loc Plus 16" Wide x 0.032" Aluminum Panels over min. 19/32" Plywood Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-74.1
 Other: Uplift load of 61.1 psf @ clip spacing of 24" o.c. and 74.1 psf @ clip spacing of 12" o.c.
Installation Instructions
 FL35396_R1_II_SS FL 35396 INSTALL DETAILS.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL35396_R1_AE_R SS FL 35396 ALL REPORTS.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe