FL # FL3299-R9
Application Type Affirmation
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Fyre-Tec
Address/Phone/Email PO Box 278
701 Centennial Rd.
Wayne, NE 68787
(402) 375-3261
erine@fyre-tec.com
 
Authorized Signature Erin Eilers
erine@fyre-tec.com
 
Technical Representative Erin Eilers
Address/Phone/Email 701 Centennial Rd.
Wayne, NE 68787
(402) 375-3261
erine@fyretec.com
 
Quality Assurance Representative Erin Eilers
Address/Phone/Email 701 Centennial Rd
Wayne, NE 68787
(402) 375-3261
erine@fyre-tec.com
 
Category Windows
Subcategory Single Hung
 
Compliance Method Certification Mark or Listing
 
Certification Agency UL LLC
Validated By UL LLC
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A440-112011
AAMA/WDMA/CSA 101/I.S.2/A440-172017
 
Equivalence of Product Standards
Certified By

Approved Certification Agency
FL3299_R9_Equiv_Fyre Tec FBC UL-QA Confirmation Letter.pdf
 
 
 
Documentation from approved Evaluation or Validation Entity
 


FL3299_R9_COC_925P Certificate of Compliance.pdf
 
Product Approval Method Method 1 Option A
 
Date Submitted 08/10/2023
Date Validated 08/10/2023
Date Pending FBC Approval
Date Approved 08/17/2023
 
Summary of Products
FL # Model, Number or Name Description
3299.1 Series 925P Steel Single Hung Steel Fire Rated - Non Impact with Mulled Option.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +55/-55
 Other: 925P R-PG55-H Maximum individual window size (width x height) 4'0" x 6'0". Mulled Assemblies Maximum Opening (width x height) 6'0" x 6'0". Mullion assemblies have optional structural testing of +75/-75 DP. All windows to be glazed with minimum 3/16 FireLite glass OR 11/16" Insulated unit consisting of clear anneal or Low-E glass and Firelite ceramic glazing. (SEE INSTALLATION INSTRUCTIONS FOR ADDITIONAL INFORMATION)
Certification Agency Certificate
 FL3299_R9_C_CAC_925P Certificate.pdf
 FL3299_R9_C_CAC_Fyre-tec 925P UL Report Letter.pdf
Quality Assurance Contract Expiration Date
 02/26/2026
Installation Instructions
 FL3299_R9_II_925P FL Mulled Installation.pdf
 FL3299_R9_II_925P Fl_Installation.pdf
 Verified By: UL LLC
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe