Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL32994-R5
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Petersen Aluminum Corp.
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(954) 461-7055
ndelfino@petersenmail.com
 
Authorized Signature Sal Delfino
sdelfino@petersenmail.com
 
Technical Representative Sal Delfino
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(954) 931-1392
sdelfino@petersenmail.com
 
Quality Assurance Representative Nick Delfino
Address/Phone/Email 1500 N. University Drive
Suite 201-G
Coral Springs, FL 33071
(954) 461-7055
ndelfino@petersenmail.com
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Test Report
 
Testing Lab Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL
Farabaugh Engineering and Testing, Inc.
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Donald Flood, FL PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL32994_R5_COI_COI Farabaugh FET.pdf
FL32994_R5_COI_Intertek Certificate of Independence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E15922017
TAS-1252003
UL 18972015
UL 5802006
 
Equivalence of Product Standards
Certified By

Approved Testing Lab
FL32994_R5_Equiv_Equivalency Letter ASTM1592 and UL1897.pdf
FL32994_R5_Equiv_Equivalency of Standard letters.pdf
 
 
 
 
Product Approval Method Method 1 Option B
 
Date Submitted 09/20/2023
Date Validated 10/04/2023
Date Pending FBC Approval 10/10/2023
Date Approved 12/13/2023
 
Summary of Products
          Page 1 / 2    
FL # Model, Number or Name Description
32994.1 32994.01 PAC-150 x 90° Seam (S1) .032" (min.) x 12" thru 20" Wide Aluminum Panel over Wood Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-99.3
 Other: Uplift Load for 20" wide panel w/two screws per clip: 6" o/c -99.3 PSF, 12" o/c -89.3 PSF, 18" o/c -79.3 PSF, 24" o/c -69.3 PSF. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_LOAD TABLES 0.032 n0374.03-450-18-r0.pdf
 FL32994_R5_II_PAC-150 typ install details.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL
Test Reports
 FL32994_R5_TR_BCIS 0.032 n0374.03-450-18-r0.pdf
32994.2 32994.02 PAC-150 x 180° Seam (S2) .032" (min.) x 12" thru 20" Wide Aluminum Panel over Wood Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-166.8
 Other: Uplift Load for 20" wide panel w/two screws per clip: 12" o/c -166.8 PSF, 18" o/c -142.8 PSF, 24" o/c -118.9 PSF, 30" o/c -94.9 PSF, 36" o/c -71.0 PSF. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_LOAD TABLES 0.032 n0374.03-450-18-r0.pdf
 FL32994_R5_II_PAC-150 typ install details.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL
Test Reports
 FL32994_R5_TR_BCIS 0.032 n0374.03-450-18-r0.pdf
32994.3 32994.03 PAC-150 x 90° Seam (S1) 24 ga. (min.) x 12" thru 20" Wide Steel Panel over Wood Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-114.3
 Other: Uplift Load for 20" wide panel w/two screws per clip: 6" o/c -114.3 PSF, 12" o/c -99.3 PSF, 18" o/c -84.3 PSF, 24" o/c -69.3 PSF. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_LOAD TABLES 24 ga. n0374.04-450-18-r0.pdf
 FL32994_R5_II_PAC-150 typ install details.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL
Test Reports
 FL32994_R5_TR_BCIS 24 ga. n0374.04-450-18-r0.pdf
32994.4 32994.04 PAC-150 x 180° Seam (S2) 24 ga. (min.) x 12" thru 20" Wide Steel Panel over Wood Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-136.8
 Other: Uplift Load for 20" wide panel w/two screws per clip: 12" o/c -136.8 PSF, 18" o/c -122.2 PSF, 24" o/c -107.6 PSF, 30" o/c -93.1 PSF, 36" o/c -78.5 PSF. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_LOAD TABLES 24 ga. n0374.04-450-18-r0.pdf
 FL32994_R5_II_PAC-150 typ install details.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL
Test Reports
 FL32994_R5_TR_BCIS 24 ga. n0374.04-450-18-r0.pdf
32994.5 32994.05 SNAP-CLAD (S1) .032" (min.) x 12" thru 18" Wide Aluminum Panel over Wood Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-153.5
 Other: Uplift Load for 18" wide panel w/two screws per clip: 6" o/c -153.5 PSF, 12" o/c -135.5 PSF, 18" o/c -117.5 PSF, 24" o/c -99.5 PSF, 30" o/c -81.5 PSF, 36" o/c -63.5 PSF. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_LOAD TABLE M5239.04-450-18 SNCLD 0.032 ALUM OVER WOOD.pdf
 FL32994_R5_II_Snap-Clad typ install details.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL
Test Reports
 FL32994_R5_TR_m5239.04-450-18-r0 SNCLD 0.032 ALUM OVER WOOD.pdf
32994.6 32994.06 SNAP-CLAD (S2) .040" (min.) x 12" thru 18" Wide Aluminum Panel over Wood Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-174.2
 Other: Uplift Load for 18" wide panel w/two screws per clip: 6" o/c -174.2 PSF, 12" o/c -158.1 PSF, 18" o/c -141.9 PSF, 24" o/c -128.8 PSF, 30" o/c -109.6 PSF, 36" o/c -93.5 PSF. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_LOAD TABLE M5239.03-450-18 SNCLD 0.040 ALUM OVER WOOD.pdf
 FL32994_R5_II_Snap-Clad typ install details.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL
Test Reports
 FL32994_R5_TR_m5239.03-450-18-r0 SNCLD 0.040 ALUM OVER WOOD.pdf
32994.7 32994.07 SNAP-CLAD (S3) 24 ga. (min.) x 12" thru 18" Wide Steel Panel over Wood Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-144.5
 Other: Uplift Load for 18" wide panel w/two screws per clip: 6" o/c -144.5 PSF, 12" o/c -128.1 PSF, 18" o/c -111.9 PSF, 24" o/c -95.8 PSF, 30" o/c -79.6 PSF, 36" o/c -63.5 PSF. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_LOAD TABLE M5239.05-450-18 SNCLD 24 GA. STEEL OVER WOOD.pdf
 FL32994_R5_II_Snap-Clad typ install details.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL
Test Reports
 FL32994_R5_TR_m5239.05-450-18-r0 SNCLD 24 GA. STEEL OVER WOOD.pdf
32994.8 32994.08 Tite-Loc Plus (S1) .032" (min.) x 12" thru 18" Wide Aluminum Panel over Wood Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-174.2
 Other: Uplift Load for 18" wide panel w/two screws per clip: 6" o/c -174.2 PSF, 12" o/c -159.2 PSF, 18" o/c -144.2 PSF, 24" o/c -129.2 PSF, 30" o/c -96.4 PSF, 36" o/c -63.5 PSF. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_LOAD TABLE M5239.02-450-18 TLP 0.032 ALUM OVER WOOD.pdf
 FL32994_R5_II_Tite-Loc Plus typ install details.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL
Test Reports
 FL32994_R5_TR_m5239.02-450-18-r0 TLP 0.032 ALUM OVER WOOD.pdf
32994.9 32994.09 Tite-Loc Plus (S2) 24 ga. (min.) x 12" thru 18" Wide Steel Panel over Wood Deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-204.5
 Other: Uplift Load for 18" wide panel w/two screws per clip: 6" o/c -204.5 PSF, 12" o/c -176.3 PSF, 18" o/c -148.1 PSF, 24" o/c -119.9 PSF, 30" o/c -91.7 PSF, 36" o/c -63.5 PSF. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_LOAD TABLE M5239.01-450-18 TLP 24 GA. STEEL OVER WOOD.pdf
 FL32994_R5_II_Tite-Loc Plus typ install details.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL
Test Reports
 FL32994_R5_TR_m5239.01-450-18-r0 TLP 24 GA. STEEL OVER WOOD.pdf
32994.10 32994.10 PAC T-250 (S1) 16" Wide x .032" (min) Aluminum Panel w/Continuous Clips
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-140.40
 Other: Uplift load for 16" wide panel is -78.00 PSF w/screw spacing of 60" o.c. and -140.40 PSF w/screw spacing of 24" o.c. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_T-250 Installation Details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL32994_R5_TR_T-250 E1592 .032 aluminum.pdf
32994.11 32994.11 PAC T-250 (S2) 16" Wide x .032" (min) Aluminum Panel w/Individual Clips
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-65.00
 Other: Uplift load for 16" wide panel is -28.60 PSF w/clip spacing of 60" o.c. and -65.00 PSF w/clip spacing of 24" o.c. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_T-250 Installation Details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL32994_R5_TR_T-250 E1592 .032 aluminum.pdf
32994.12 32994.12 PAC T-250 (S3) 16" Wide x .040" (min) Aluminum Panel w/Continuous Clips
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-127.15
 Other: Uplift load for 16" wide panel is -91.00 PSF w/screw spacing of 60" o.c. and -127.15 PSF w/screw spacing of 24" o.c. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_T-250 Installation Details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL32994_R5_TR_T-250 E1592 .040 aluminum.pdf
32994.13 32994.13 PAC T-250 (S4) 16" Wide x .040" (min) Aluminum Panel w/Individual Clips
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-78.00
 Other: Uplift load for 16" wide panel is -38.75 PSF w/clip spacing of 60" o.c. and -78.00 PSF w/clip spacing of 24" o.c. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_T-250 Installation Details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL32994_R5_TR_T-250 E1592 .040 aluminum.pdf
32994.14 32994.14 PAC T-250 (S5) 16" Wide x 24 Ga. (min) Steel Panel w/Continuous Clips
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-119.85
 Other: Uplift load for 16" wide panel is -98.80 PSF w/screw spacing of 60" o.c. and -119.85 PSF w/screw spacing of 24" o.c. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_T-250 Installation Details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL32994_R5_TR_T-250 E1592 24 ga. steel.pdf
32994.15 32994.15 PAC T-250 (S6) 16" Wide x 24 Ga. (min) Steel Panel w/Individual Clips
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-65.00
 Other: Uplift load for 16" wide panel is -33.80 PSF w/clip spacing of 60" o.c. and -65.00 PSF w/clip spacing of 24" o.c. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_T-250 Installation Details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL32994_R5_TR_T-250 E1592 24 ga. steel.pdf
32994.16 32994.16 PAC T-250 (S7) 16" Wide x 22 Ga. (min) Steel Panel w/Continuous Clips
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-147.95
 Other: Uplift load for 16" wide panel is -91.00 PSF w/screw spacing of 60" o.c. and -147.95 PSF w/screw spacing of 24" o.c. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_T-250 Installation Details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL32994_R5_TR_T-250 E1592 22 ga. steel.pdf
32994.17 32994.17 PAC T-250 (S8) 16" Wide x 22 Ga. (min) Steel Panel w/Individual Clips
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-72.80
 Other: Uplift load for 16" wide panel is -46.85 PSF w/clip spacing of 60" o.c. and -72.80 PSF w/clip spacing of 24" o.c. Install per manufacturer's details. Not for use in HVHZ.
Installation Instructions
 FL32994_R5_II_T-250 Installation Details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL32994_R5_TR_T-250 E1592 22 ga. steel.pdf
32994.18 7.2 Panel (S1) 2' - 5' Spans 36" Wide x 24 Ga. (min.) Steel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-159.70
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -159.70 @ 2', -132.70 @ 3', -105.80 @ 4', -78.85 @ 5'. Not for use in HVHZ. Safety Factor of 2.0 is included.
Installation Instructions
 FL32994_R5_II_Installation Details ALL.pdf
 FL32994_R5_II_Negative Load Table 2 to 5 FT spans.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL32994_R5_TR_T277-08_e1592_24_GA.pdf
32994.19 7.2 Panel (S2) 2' - 5' Spans 36" Wide x .032" (min.) Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-104.05
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -104.05 @ 2', -89.70 @ 3', -75.40 @ 4', -61.15 @ 5', Not for use in HVHZ. Safety Factor of 2.0 is included.
Installation Instructions
 FL32994_R5_II_Installation Details ALL.pdf
 FL32994_R5_II_Negative Load Table 2 to 5 FT spans.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL32994_R5_TR_T281-08_e1592_032.pdf
32994.20 7.2 Panel (S3) 1' - 5' Spans 36" Wide x .050" (min.) Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-192.10
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -192.10 @ 1', -162.20 @ 2', -132.40 @ 3', -102.50 @ 4', -72.75 @ 5'. Not for use in HVHZ. Safety Factor of 2.0 is included.
Installation Instructions
 FL32994_R5_II_Installation Details ALL.pdf
 FL32994_R5_II_Negative Load Table 1 to 5 FT spans.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL32994_R5_TR_ALL test reports 1 FT to 5 FT spans.pdf