33513.1 |
SH-510 |
SH-510 Vinyl Single Hung Impact |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile, see installation dwgs. for Max. size and DP. Outer lite in I.G. must be safety glazed when used above 30 ft. in HVHZ. Glass complies to ASTM E1300. |
Installation Instructions FL33513_R2_II_PEL-155C.pdf Verified By: Lucas A. Turner 58201 Created by Independent Third Party: Yes Evaluation Reports FL33513_R2_AE_EvalReportPEL155C.pdf Created by Independent Third Party: Yes |
|
33513.2 |
SH-510 |
SH-510 Cont. Hd. & Sill (double Single Hung), Impact, 74 1/8" x 63". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile, see installation dwgs. for DP. Max. unit size 72-7/8" x 61-3/4". Outer lite in I.G. must be safety glazed when used above 30 ft. in HVHZ. Glass complies to ASTM E1300. |
Installation Instructions FL33513_R2_II_PEL-440B.pdf Verified By: Lucas A. Turner 58201 Created by Independent Third Party: Yes Evaluation Reports FL33513_R2_AE_EvalReportPEL440B.pdf Created by Independent Third Party: Yes |
|
33513.3 |
SH-510 |
SH-510 Cont. Hd. & Sill (double single Hung), Impact, 74 1/8" x 72". |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +67.5/-67.5 Other: Large Missile, DP+/- 67.5 psf, Max. size 74-1/8" x 72". Outer lite in I.G. must be safety glazed when used above 30 ft. in HVHZ. Glass complies to ASTM E1300. |
Installation Instructions FL33513_R2_II_PEL-491B.pdf Verified By: Lucas A. Turner 58201 Created by Independent Third Party: Yes Evaluation Reports FL33513_R2_AE_EvalReportPEL491B.pdf Created by Independent Third Party: Yes |
|
33513.4 |
SH-510 |
SH-510 Vinyl Single Hung Oriel Window w. HD FMR, 5 HI sash. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: Large Missile, 52" x 96" w/ 5 HI sash, +/- 70 psf. FLANGE ONLY. Outer lite in I.G. must be safety glazed when used above 30 ft. in HVHZ. Glass complies to ASTM E1300. |
Installation Instructions FL33513_R2_II_PEL-295C.pdf Verified By: Lucas A. Turner 58201 Created by Independent Third Party: Yes Evaluation Reports FL33513_R2_AE_EvalReportPEL295C.pdf Created by Independent Third Party: Yes |