Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL13531-R4
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer PlyFASTner LLC
Address/Phone/Email 1951 Teakwood Road
Charleston, SC 29414
(843) 766-8199
dk@dokimengineering.net
 
Authorized Signature Do Kim
dk@dokimengineering.net
 
Technical Representative Robert Goodwin
Address/Phone/Email 1951 Teakwood Road
Charleston, SC 29414
(843) 766-8199
robert@plyfastner.com
 
Quality Assurance Representative Robert Goodwin
Address/Phone/Email 1951 Teakwood Road
Charleston, SC 29414
(843) 766-8199
robert@plyfastner.com
 
Category Shutters
Subcategory Storm Panels
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Do Kim, P.E.
Florida License PE-49497
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2023
Validated By James L. Buckner, P.E. @ CBUCK Engineering
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL13531_R4_COI_certificate of independence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E18862012
ASTM E19962017
ASTM E3302002
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 04/13/2021
Date Validated 04/14/2021
Date Pending FBC Approval 04/19/2021
Date Approved 06/08/2021
Date Revised 08/02/2023
 
Summary of Products
FL # Model, Number or Name Description
13531.1 PlyFASTner Opening protection panel and bracket system.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +52/-52
 Other: Not for use within HVHZ and in Wind Zone 3 below 30 feet for Enhanced Protection. See installation instructions for anchor strength values and fastening schedule. DP is nominal allowable pressure.
Installation Instructions
 FL13531_R4_II_2020 FBC- PlyFASTner- Product Approval Installation drawing.pdf
 Verified By: Do Kim, P.E. PE 49497
 Created by Independent Third Party: Yes
Evaluation Reports
 FL13531_R4_AE_2020 FBC PlyFASTner Evaluation Report.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex