11488.1 |
1600 Wall System 1 Level E Curtain Wall |
1600 Wall System 1 Level E Curtain Wall, 3" sightline |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +100/-123 Other: Curtain wall size, assembly and installation requirements are to be as specified in the attached drawing no. 1599. Job required design wind pressure shall be calculated in accordance with the Flordia Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This curtain wall system is rated as a wind zone 4 missile level "E" product. |
Installation Instructions FL11488_R7_II_16003E Dwg4.pdf Verified By: Scott Wolters, P.E. 62354 Created by Independent Third Party: Yes Evaluation Reports FL11488_R7_AE_16003E Eval4.pdf Created by Independent Third Party: Yes |
|
11488.2 |
1600 Wall System 1 Level E Curtain Wall |
1600 Wall System 1 Level E Curtain Wall, 2-1/2" sightline |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +90/-90 Other: Curtain wall size, assembly and installation requirements are to be as specified in the attached drawing no. 1599. Job required design wind pressure shall be calculated in accordance with the Flordia Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This curtain wall system is rated as a wind zone 4 missile level "E" product. |
Installation Instructions FL11488_R7_II_1600E Dwg3.pdf Verified By: Scott Wolters, P.E. 62354 Created by Independent Third Party: Yes Evaluation Reports FL11488_R7_AE_1600E Eval3.pdf Created by Independent Third Party: Yes |