FL # FL19979-R3
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg.keeler@owenscorning.com
 
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
 
Technical Representative Greg Keeler
Address/Phone/Email 2790 Columbus Road
Granville, OH 43023
(740) 321-6345
greg.keeler@owenscorning.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Modified Bitumen Roof System
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 01/05/2027
Validated By John W. Knezevich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL19979_R3_COI_2023_07_COI_NIEMINEN.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM D61632016
ASTM D61642016
ASTM G1552013
FM 44702016
FM 44742011
TAS 1142011
UL 18972015
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 12/27/2023
Date Validated 12/28/2023
Date Pending FBC Approval 01/02/2024
Date Approved 02/13/2024
 
Summary of Products
FL # Model, Number or Name Description
19979.1 DeckSeal Modified Bitumen Roof Systems (HVHZ) Self-adhering, SBS modified bitumen roof systems for use in FBC HVHZ jurisdictions
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: No
 Impact Resistant: N/A
 Design Pressure: +N/A/-127.5
 Other: 1.) The design pressure herein pertains to one assembly. Refer to PEER Appendix for all assemblies and max. allowable design pressures. 2.) Refer to PEER Section 5 for Limits of Use.
Installation Instructions
 FL19979_R3_II_2023_12_27_FINAL_A1_PEER-OCPLYG-006.B_HVHZ_FL19979-R3.pdf
 Verified By: Robert Nieminen PE-59166
 Created by Independent Third Party: Yes
Evaluation Reports
 FL19979_R3_AE_2023_12_27_FINAL_PEER-OCPLYG-006.B_HVHZ_FL19979-R3.pdf
 Created by Independent Third Party: Yes
19979.2 DeckSeal Modified Bitumen Roof Systems (NON-HVHZ) Self-adhering, SBS modified bitumen roof systems for use in FBC non-HVHZ jurisdictions
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-135
 Other: 1.) The design pressure herein pertains to one assembly. Refer to PEER Appendix for all assemblies and max. allowable design pressures. 2.) Refer to PEER Section 5 for Limits of Use.
Installation Instructions
 FL19979_R3_II_2023_12_27_FINAL_A1_PEER-OCPLYG-006.A_NON-HVHZ_FL19979-R3.pdf
 Verified By: Robert Nieminen PE-59166
 Created by Independent Third Party: Yes
Evaluation Reports
 FL19979_R3_AE_2023_12_27_FINAL_PEER-OC-OCPLYG-006.A_NON-HVHZ_FL19979-R3.pdf
 Created by Independent Third Party: Yes
 