35284.1 |
Impervia 2.0 Fixed Casement (Non-HVHZ) (Impact) |
Impervia 2.0 Fixed Casement (Non-HVHZ) (Impact) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: See Installation Instructions and Product Evaluation Report for allowable sizes, configurations, installation requirements and limits of use. |
Certification Agency Certificate FL35284_R3_C_CAC_Pella 1512.pdf Quality Assurance Contract Expiration Date 06/23/2030 Installation Instructions FL35284_R3_II_PLA002 SS 2023-08-01.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL35284_R3_AE_PER8632 SS 2023-08-01.pdf Created by Independent Third Party: Yes |
|
35284.2 |
Impervia Model 2 Fixed Casement Window |
71.5" x 79.5" Non-Impact Fiberglass Fixed Window |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: Glass shall conform to the current ASTM E1300 standard and shall be safety glazed when required by FBC. |
Certification Agency Certificate FL35284_R3_C_CAC_411-H-1512.00,01.pdf Quality Assurance Contract Expiration Date 06/23/2030 Installation Instructions FL35284_R3_II_Drawing 1988.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL35284_R3_AE_Drawing 1988.pdf Created by Independent Third Party: Yes |
|
35284.3 |
Impervia Model 2 Fixed Casement Window |
59.5" x 79.5" Non-Impact Fiberglass Fixed Window |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Glass shall conform to the current ASTM E1300 standard and shall be safety glazed when required by FBC. |
Certification Agency Certificate FL35284_R3_C_CAC_411-H-1512.02,03.pdf Quality Assurance Contract Expiration Date 06/23/2030 Installation Instructions FL35284_R3_II_Drawing 1988.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL35284_R3_AE_Drawing 1988.pdf Created by Independent Third Party: Yes |
|
35284.4 |
Impervia Model 2 Fixed Casement Window |
59.5" x 59.5" Non-Impact Fiberglass Fixed Window |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-60 Other: Glass shall conform to the current ASTM E1300 standard and shall be safety glazed when required by FBC. |
Certification Agency Certificate FL35284_R3_C_CAC_411-H-1512.04,05.pdf Quality Assurance Contract Expiration Date 07/29/2030 Installation Instructions FL35284_R3_II_Drawing 1988.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL35284_R3_AE_Drawing 1988.pdf Created by Independent Third Party: Yes |