6525.1 |
ELDH 4276 |
Elevate Fiberglass Clad Wood Double Hung 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Max Size: 41.5 x 75.75 inches. Glass complies with ASTM E1300 |
Certification Agency Certificate FL6525_R13_C_CAC_CCL783.65.66.pdf Quality Assurance Contract Expiration Date 02/13/2025 Installation Instructions FL6525_R13_II_52745 ELDH.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6525.2 |
ELDH 4284 |
Elevate Fiberglass Clad Wood Double Hung 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size: 41.5 x 83.75 inches. Glass complies with ASTM E1300 |
Certification Agency Certificate FL6525_R13_C_CAC_CCL783.59.60.pdf Quality Assurance Contract Expiration Date 02/16/2025 Installation Instructions FL6525_R13_II_00052745 ELDH.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6525.3 |
ELDH 5476 |
Elevate Fiberglass Clad Wood Double Hung 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size: 53.5 x 75.75 inches. Glass complies with ASTM E1300 |
Certification Agency Certificate FL6525_R13_C_CAC_CCL783.61.62.pdf Quality Assurance Contract Expiration Date 02/16/2025 Installation Instructions FL6525_R13_II_00052745 ELDH.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6525.4 |
ELDH 5484 |
Elevate Fiberglass Clad Wood Double Hung 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Max frame Size: 53.5 x 83.75 inches. Glass complies with ASTM E1300 |
Certification Agency Certificate FL6525_R13_C_CAC_CCL783.55.56.pdf Quality Assurance Contract Expiration Date 02/16/2025 Installation Instructions FL6525_R13_II_00052745 ELDH.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6525.5 |
ELDH COTTAGE 4268 |
Elevate Fiberglass Clad Wood Double Hung Cottage 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max frame Size: 41.5 x 67.75 inches. Glass complies with ASTM E1300 |
Certification Agency Certificate FL6525_R13_C_CAC_CCL783.67.68.pdf Quality Assurance Contract Expiration Date 02/16/2025 Installation Instructions FL6525_R13_II_00052745 ELDH.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6525.6 |
ELDH HP 5476 |
Elevate Fiberglass Clad Wood Double Hung High Performance 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Max Size: 53.5 x 75.75 inches. Glass complies with ASTM E1300 |
Certification Agency Certificate FL6525_R13_C_CAC_CCL783.63.64.pdf Quality Assurance Contract Expiration Date 02/16/2025 Installation Instructions FL6525_R13_II_00052745 ELDH.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6525.7 |
ELDH HP 5484 |
Elevate Fiberglass Clad Wood Double Hung High Performance 407-H-783 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max frame Size: 53.5 x 83.75 inches. Glass complies with ASTM E1300 |
Certification Agency Certificate FL6525_R13_C_CAC_CCL783.57.58.pdf Quality Assurance Contract Expiration Date 02/16/2025 Installation Instructions FL6525_R13_II_00052745 ELDH.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6525.8 |
ELDH IN 4284 |
Elevate Fiberglass Clad Wood Double Hung Insert 407-H-1123 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max frame Size: 42-1/16" x 84-1/2". Glass complies with ASTM E1300 |
Certification Agency Certificate FL6525_R13_C_CAC_CCL1123.02.03.pdf Quality Assurance Contract Expiration Date 04/21/2025 Installation Instructions FL6525_R13_II_115532 ELDHIN.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
6525.9 |
ELDH IN 5484 |
Elevate Fiberglass Clad Wood Double Hung Insert 407-H-1123 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Max frame Size: 54-1/16 x 84-1/2 inches. Glass complies with ASTM E1300 |
Certification Agency Certificate FL6525_R13_C_CAC_CCL1123.00.01.pdf Quality Assurance Contract Expiration Date 04/21/2025 Installation Instructions FL6525_R13_II_115532 ELDHIN.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |