33230.1 |
7.2 Panel (S1) 2' - 5' Spans |
36" Wide x 24 Ga. (min.) Steel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +N/A/-159.70 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -159.70 @ 2‘, -132.70 @ 3', -105.80 @ 4', -78.85 @ 5‘. Not for use in HVHZ. Safety Factor of 2.0 is included. |
Installation Instructions FL33230_R6_II_Installation Details ALL.pdf FL33230_R6_II_Negative Load Table 2 to 5 FT spans.pdf Verified By: Farabaugh Engineering and Testing, Inc. Test Reports FL33230_R6_TR_2651A0001 Report ASTM E1886 Petersen 24ga 7.2 Rib Panel.pdf FL33230_R6_TR_T277-08_e1592_24_GA.pdf |
|
33230.2 |
7.2 Panel (S2) 2' - 5' Spans |
36" Wide x .032" (min.) Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-104.0 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -104.0 @ 2‘, -89.7 @ 3', -75.4 @ 4', -61.1 @ 5‘. Not for use in HVHZ. Safety Factor of 2.0 is included. |
Installation Instructions FL33230_R6_II_Installation Details ALL.pdf FL33230_R6_II_Negative Load Table alum 2 to 5 FT spans.pdf Verified By: Farabaugh Engineering and Testing, Inc. Test Reports FL33230_R6_TR_T281-08_e1592_032.pdf |
|
33230.3 |
7.2 Panel (S3) 1' - 5' Spans |
36" Wide x .050" (min.) Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-192.10 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -192.10 @ 1‘, -162.20 @ 2', -132.40 @ 3', -102.50 @ 4', -72.75 @ 5‘. Not for use in HVHZ. Safety Factor of 2.0 is included. |
Installation Instructions FL33230_R6_II_Installation Details ALL.pdf FL33230_R6_II_Negative Load Table 1 to 5 FT spans.pdf Verified By: Farabaugh Engineering and Testing, Inc. Test Reports FL33230_R6_TR_ALL test reports 1 FT to 5 FT spans.pdf |
|
33230.4 |
7.2 Panel (S4) 7 - 10' Spans |
36" Wide x .050" (min.) Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-57.20 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -57.20 @ 7‘, -48.50 @ 8‘, -39.85 @ 9‘, -31.20 @ 10‘. Not for use in HVHZ. Safety Factor of 2.0 is included. |
Installation Instructions FL33230_R6_II_Installation Details ALL.pdf FL33230_R6_II_Negative Load Table 7 to 10 FT spans.pdf Verified By: Farabaugh Engineering and Testing, Inc. Test Reports FL33230_R6_TR_T302-22_050_7_and_10_FT.pdf |
|
33230.5 |
Board & Batten (A1) |
12" thru 16" wide x .032" (min.) Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +100/-84 Other: Metal panels & metal siding installed in front of CBS construction or 5/8" plywood supported by 2x studs or 2x6 – 18 Ga. metal studs, each at 16" o.c. are exempt from impact & positive pressure tests. |
Installation Instructions FL33230_R6_II_Installation Details ALL.pdf Verified By: Donald Flood 31333 Test Reports FL33230_R6_TR_2651T0006A Report for TAS-202 and TAS-203 in 0.032 Aluminum Board and Batten.pdf FL33230_R6_TR_2651T0008A.01 Report for E283 and E331 Board and Batten.pdf |
|
33230.6 |
Board & Batten (S1) |
12" thru 16" wide x 24 Ga. (min.) Steel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +120/-112 Other: Metal panels & metal siding installed in front of CBS construction or 5/8" plywood supported by 2x studs or 2x6 – 18 Ga. metal studs, each at 16" o.c. are exempt from impact & positive pressure tests. |
Installation Instructions FL33230_R6_II_Installation Details ALL.pdf Verified By: Donald Flood 31333 Test Reports FL33230_R6_TR_2651T0007A Report for TAS-202 and TAS-203 in 24 ga. Steel Board and Batten.pdf FL33230_R6_TR_2651T0008A.01 Report for E283 and E331 Board and Batten.pdf |
|
33230.7 |
Box Rib 1 (A1) |
12" Wide x .032" (min.) Aluminum w/Clip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-57.3 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -57.3 @ 2‘, -53.4 @ 2.5‘, -49.5 @ 3‘, -45.6 @ 3.5‘, -41.6 @ 4‘, -37.7 @ 4.5‘, -33.8 @ 5‘. Not for use in HVHZ. |
Installation Instructions FL33230_R6_II_PAC Box Rib 1 details.pdf Verified By: Farabaugh Engineering and Testing, Inc. Test Reports FL33230_R6_TR_ASTM E-1592_Box Rib_1 x .032 (min.) Alum with clip and loads.pdf FL33230_R6_TR_PAC Box Rib 1 x .032 Alum w Clip ASTM 1592 Summary Load Chart.pdf |
|
33230.8 |
Box Rib 1 (A2) |
12" Wide x 24 Ga. (min.) Steel w/Clip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-80.6 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -80.6 @ 2‘, -74.5 @ 2.5‘, -68.5 @ 3‘, -62.4 @ 3.5‘, -56.3 @ 4‘, -50.3 @ 4.5‘, -44.2 @ 5‘. Not for use in HVHZ. |
Installation Instructions FL33230_R6_II_PAC Box Rib 1 details.pdf Verified By: Farabaugh Engineering and Testing, Inc. Test Reports FL33230_R6_TR_ASTM E-1592_Box Rib_1 x 24 GA (min.) Steel with clip and loads.pdf FL33230_R6_TR_PAC Box Rib 1 x 24 GA w Clip ASTM 1592 Summary Load Chart.pdf |
|
33230.9 |
Box Rib 2 (A3) |
12" Wide x .032" (min.) Aluminum w/Clip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.4 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -101.4 @ 2‘, -91.5 @ 2.5‘, -81.5 @ 3‘, -71.6 @ 3.5‘, -61.6 @ 4‘, -51.7 @ 4.5‘, -41.7 @ 5‘. Not for use in HVHZ. |
Installation Instructions FL33230_R6_II_PAC Box Rib 2 details.pdf Verified By: Farabaugh Engineering and Testing, Inc. Test Reports FL33230_R6_TR_ASTM E-1592_Box Rib_2 x .032 (min.) Alum with clip and loads.pdf FL33230_R6_TR_PAC Box Rib 2 x .032 Alum w Clip ASTM 1592 Summary Load Chart.pdf |
|
33230.10 |
Box Rib 2 (A4) |
12" Wide x 24 Ga. (min.) Steel w/Clip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-88.5 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -88.5 @ 2‘, -79.8 @ 2.5‘, -71.2 @ 3‘, -62.5 @ 3.5‘, -53.8 @ 4‘, -45.2 @ 4.5‘, -36.5 @ 5‘. Not for use in HVHZ. |
Installation Instructions FL33230_R6_II_PAC Box Rib 2 details.pdf Verified By: Farabaugh Engineering and Testing, Inc. Test Reports FL33230_R6_TR_ASTM E-1592_Box Rib-2 x 24 GA (min.) Steel with clip and loads.pdf FL33230_R6_TR_PAC Box Rib 2 x 24 GA w Clip ASTM 1592 Summary Load Chart.pdf |
|
33230.11 |
Box Rib 3 (A5) |
12" Wide x .032" (min.) Aluminum w/Clip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-75.4 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -75.4 @ 2’, -69.3 @ 2.5’, -63.3 @ 3’, -57.2 @ 3.5’, -51.1@ 4’, -45.1 @ 4.5’, -39.0 @ 5’. Not for use in HVHZ. |
Installation Instructions FL33230_R6_II_PAC Box Rib 3 details.pdf Verified By: Farabaugh Engineering and Testing, Inc. Test Reports FL33230_R6_TR_ASTM E-1592_Box Rib_3 x .032 (min.) Alum with clip and loads.pdf FL33230_R6_TR_PAC Box Rib 3 x 0.032 Alum w Clip ASTM 1592 Summary Load Table.pdf |
|
33230.12 |
Box Rib 3 (A6) |
12" Wide x 24 Ga. (min.) Steel w/Clip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.0 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -78.0 @ 2’, -73.2 @ 2.5’, -68.5 @ 3’, -63.7 @ 3.5’, -58.9 @ 4’, -54.1 @ 4.5’, -49.4 @ 5’. Not for use in HVHZ. |
Installation Instructions FL33230_R6_II_PAC Box Rib 3 details.pdf Verified By: Farabaugh Engineering and Testing, Inc. Test Reports FL33230_R6_TR_ASTM E-1592_Box Rib_3 x 24 GA (min.) Steel with clip and loads.pdf FL33230_R6_TR_PAC Box Rib 3 x 24 GA w Clip ASTM 1592 Summary Load Table.pdf |
|
33230.13 |
Box Rib 4 (A7) |
12" Wide x .032" (min.) Aluminum w/Clip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-85.6 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -85.6 @ 2’, -78.3 @ 2.5’, -71.0 @ 3’, -63.7 @ 3.5’, -56.3 @ 4’, -49.0 @ 4.5’, -41.7 @ 5’. Not for use in HVHZ. |
Installation Instructions FL33230_R6_II_PAC Box Rib 4 details.pdf Verified By: Farabaugh Engineering and Testing, Inc. Test Reports FL33230_R6_TR_ASTM E-1592_Box Rib_4 x .032 (min.) Alum with clip and loads.pdf FL33230_R6_TR_PAC Box Rib 4 x 0.032 Alum w Clip ASTM 1592 Summary Load Table.pdf |
|
33230.14 |
Box Rib 4 (A8) |
12" Wide x 24 Ga. (min.) Steel w/Clip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-105.2 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -105.2 @ 2‘, -95.0 @ 2.5‘, -84.8 @ 3‘, -74.5 @ 3.5‘, -64.3 @ 4’, -54.0 @ 4.5‘, -43.7 @ 5‘. Not for use in HVHZ.
|
Installation Instructions FL33230_R6_II_PAC Box Rib 4 details.pdf Verified By: Farabaugh Engineering and Testing, Inc. Test Reports FL33230_R6_TR_ASTM E-1592_Box Rib_4 x 24 GA (min.) Steel with clip and loads.pdf FL33230_R6_TR_PAC Box Rib 4 x 24 GA w Clip ASTM 1592 Summary Load Table.pdf |
|
33230.15 |
Modular AL (050) |
3" deep x 24" wide x 0.050" (min.) Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-57.2 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -57.2 @ (24") 2.0'. Not for use in HVHZ. |
Installation Instructions FL33230_R6_II_PAC Modular AL details.pdf Verified By: Farabaugh Engineering and Testing, Inc. Test Reports FL33230_R6_TR_ASTM E1592_3 in deep x 24 in x 0.050 in (min.) Aluminum.pdf |
|
33230.16 |
Modular AL (080) |
3" deep x 30" wide x 0.080" (min.) Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-57.2 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -57.2 @ (30") 2.5'. Not for use in HVHZ. |
Installation Instructions FL33230_R6_II_PAC Modular AL details.pdf Verified By: Farabaugh Engineering and Testing, Inc. Test Reports FL33230_R6_TR_ASTM E1592_3 in deep x 30 in x 0.080 in (min.) Aluminum.pdf |