Product Approval Menu > Application Detail
 
FL # FL33230-R6
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Petersen Aluminum Corp.
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(954) 461-7055
ndelfino@petersenmail.com
 
Authorized Signature Sal Delfino
sdelfino@petersenmail.com
 
Technical Representative Sal Delfino
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(954) 931-1392
sdelfino@petersenmail.com
 
Quality Assurance Representative Nicholas Delfino
Address/Phone/Email 102 Northpoint Parkway
Building 106
Acworth, GA 30102
(954) 461-7055
ndelfino@petersenmail.com
 
Category Panel Walls
Subcategory Siding
 
Compliance Method Test Report
 
Testing Lab Farabaugh Engineering and Testing, Inc.
PRI Construction Materials Technologies, LLC
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Donald Flood, FL PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL33230_R6_COI_COI Farabaugh FET.pdf
FL33230_R6_COI_COI PRI.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E15922017
ASTM E18862019
ASTM E19962020
ASTM E2832019
ASTM E3312016
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Approved Testing Lab
FL33230_R6_Equiv_Equivalency Letter ASTM1592.pdf
FL33230_R6_Equiv_Equivalency of Standard letters 08-05-22.pdf
FL33230_R6_Equiv_Equivalency of Standard letters 12-13-22.pdf
 
 
 
 
Product Approval Method Method 1 Option B
 
Date Submitted 06/21/2024
Date Validated 06/22/2024
Date Pending FBC Approval 06/25/2024
Date Approved 08/13/2024
 
Summary of Products
FL # Model, Number or Name Description
33230.1 7.2 Panel (S1) 2' - 5' Spans 36" Wide x 24 Ga. (min.) Steel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +N/A/-159.70
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -159.70 @ 2‘, -132.70 @ 3', -105.80 @ 4', -78.85 @ 5‘. Not for use in HVHZ. Safety Factor of 2.0 is included.
Installation Instructions
 FL33230_R6_II_Installation Details ALL.pdf
 FL33230_R6_II_Negative Load Table 2 to 5 FT spans.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R6_TR_2651A0001 Report ASTM E1886 Petersen 24ga 7.2 Rib Panel.pdf
 FL33230_R6_TR_T277-08_e1592_24_GA.pdf
33230.2 7.2 Panel (S2) 2' - 5' Spans 36" Wide x .032" (min.) Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-104.0
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -104.0 @ 2‘, -89.7 @ 3', -75.4 @ 4', -61.1 @ 5‘. Not for use in HVHZ. Safety Factor of 2.0 is included.
Installation Instructions
 FL33230_R6_II_Installation Details ALL.pdf
 FL33230_R6_II_Negative Load Table alum 2 to 5 FT spans.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R6_TR_T281-08_e1592_032.pdf
33230.3 7.2 Panel (S3) 1' - 5' Spans 36" Wide x .050" (min.) Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-192.10
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -192.10 @ 1‘, -162.20 @ 2', -132.40 @ 3', -102.50 @ 4', -72.75 @ 5‘. Not for use in HVHZ. Safety Factor of 2.0 is included.
Installation Instructions
 FL33230_R6_II_Installation Details ALL.pdf
 FL33230_R6_II_Negative Load Table 1 to 5 FT spans.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R6_TR_ALL test reports 1 FT to 5 FT spans.pdf
33230.4 7.2 Panel (S4) 7 - 10' Spans 36" Wide x .050" (min.) Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-57.20
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -57.20 @ 7‘, -48.50 @ 8‘, -39.85 @ 9‘, -31.20 @ 10‘. Not for use in HVHZ. Safety Factor of 2.0 is included.
Installation Instructions
 FL33230_R6_II_Installation Details ALL.pdf
 FL33230_R6_II_Negative Load Table 7 to 10 FT spans.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R6_TR_T302-22_050_7_and_10_FT.pdf
33230.5 Board & Batten (A1) 12" thru 16" wide x .032" (min.) Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +100/-84
 Other: Metal panels & metal siding installed in front of CBS construction or 5/8" plywood supported by 2x studs or 2x6 – 18 Ga. metal studs, each at 16" o.c. are exempt from impact & positive pressure tests.
Installation Instructions
 FL33230_R6_II_Installation Details ALL.pdf
 Verified By: Donald Flood 31333
Test Reports
 FL33230_R6_TR_2651T0006A Report for TAS-202 and TAS-203 in 0.032 Aluminum Board and Batten.pdf
 FL33230_R6_TR_2651T0008A.01 Report for E283 and E331 Board and Batten.pdf
33230.6 Board & Batten (S1) 12" thru 16" wide x 24 Ga. (min.) Steel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +120/-112
 Other: Metal panels & metal siding installed in front of CBS construction or 5/8" plywood supported by 2x studs or 2x6 – 18 Ga. metal studs, each at 16" o.c. are exempt from impact & positive pressure tests.
Installation Instructions
 FL33230_R6_II_Installation Details ALL.pdf
 Verified By: Donald Flood 31333
Test Reports
 FL33230_R6_TR_2651T0007A Report for TAS-202 and TAS-203 in 24 ga. Steel Board and Batten.pdf
 FL33230_R6_TR_2651T0008A.01 Report for E283 and E331 Board and Batten.pdf
33230.7 Box Rib 1 (A1) 12" Wide x .032" (min.) Aluminum w/Clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-57.3
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -57.3 @ 2‘, -53.4 @ 2.5‘, -49.5 @ 3‘, -45.6 @ 3.5‘, -41.6 @ 4‘, -37.7 @ 4.5‘, -33.8 @ 5‘. Not for use in HVHZ.
Installation Instructions
 FL33230_R6_II_PAC Box Rib 1 details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R6_TR_ASTM E-1592_Box Rib_1 x .032 (min.) Alum with clip and loads.pdf
 FL33230_R6_TR_PAC Box Rib 1 x .032 Alum w Clip ASTM 1592 Summary Load Chart.pdf
33230.8 Box Rib 1 (A2) 12" Wide x 24 Ga. (min.) Steel w/Clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-80.6
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -80.6 @ 2‘, -74.5 @ 2.5‘, -68.5 @ 3‘, -62.4 @ 3.5‘, -56.3 @ 4‘, -50.3 @ 4.5‘, -44.2 @ 5‘. Not for use in HVHZ.
Installation Instructions
 FL33230_R6_II_PAC Box Rib 1 details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R6_TR_ASTM E-1592_Box Rib_1 x 24 GA (min.) Steel with clip and loads.pdf
 FL33230_R6_TR_PAC Box Rib 1 x 24 GA w Clip ASTM 1592 Summary Load Chart.pdf
33230.9 Box Rib 2 (A3) 12" Wide x .032" (min.) Aluminum w/Clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-101.4
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -101.4 @ 2‘, -91.5 @ 2.5‘, -81.5 @ 3‘, -71.6 @ 3.5‘, -61.6 @ 4‘, -51.7 @ 4.5‘, -41.7 @ 5‘. Not for use in HVHZ.
Installation Instructions
 FL33230_R6_II_PAC Box Rib 2 details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R6_TR_ASTM E-1592_Box Rib_2 x .032 (min.) Alum with clip and loads.pdf
 FL33230_R6_TR_PAC Box Rib 2 x .032 Alum w Clip ASTM 1592 Summary Load Chart.pdf
33230.10 Box Rib 2 (A4) 12" Wide x 24 Ga. (min.) Steel w/Clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-88.5
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -88.5 @ 2‘, -79.8 @ 2.5‘, -71.2 @ 3‘, -62.5 @ 3.5‘, -53.8 @ 4‘, -45.2 @ 4.5‘, -36.5 @ 5‘. Not for use in HVHZ.
Installation Instructions
 FL33230_R6_II_PAC Box Rib 2 details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R6_TR_ASTM E-1592_Box Rib-2 x 24 GA (min.) Steel with clip and loads.pdf
 FL33230_R6_TR_PAC Box Rib 2 x 24 GA w Clip ASTM 1592 Summary Load Chart.pdf
33230.11 Box Rib 3 (A5) 12" Wide x .032" (min.) Aluminum w/Clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-75.4
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -75.4 @ 2’, -69.3 @ 2.5’, -63.3 @ 3’, -57.2 @ 3.5’, -51.1@ 4’, -45.1 @ 4.5’, -39.0 @ 5’. Not for use in HVHZ.
Installation Instructions
 FL33230_R6_II_PAC Box Rib 3 details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R6_TR_ASTM E-1592_Box Rib_3 x .032 (min.) Alum with clip and loads.pdf
 FL33230_R6_TR_PAC Box Rib 3 x 0.032 Alum w Clip ASTM 1592 Summary Load Table.pdf
33230.12 Box Rib 3 (A6) 12" Wide x 24 Ga. (min.) Steel w/Clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-78.0
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -78.0 @ 2’, -73.2 @ 2.5’, -68.5 @ 3’, -63.7 @ 3.5’, -58.9 @ 4’, -54.1 @ 4.5’, -49.4 @ 5’. Not for use in HVHZ.
Installation Instructions
 FL33230_R6_II_PAC Box Rib 3 details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R6_TR_ASTM E-1592_Box Rib_3 x 24 GA (min.) Steel with clip and loads.pdf
 FL33230_R6_TR_PAC Box Rib 3 x 24 GA w Clip ASTM 1592 Summary Load Table.pdf
33230.13 Box Rib 4 (A7) 12" Wide x .032" (min.) Aluminum w/Clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-85.6
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -85.6 @ 2’, -78.3 @ 2.5’, -71.0 @ 3’, -63.7 @ 3.5’, -56.3 @ 4’, -49.0 @ 4.5’, -41.7 @ 5’. Not for use in HVHZ.
Installation Instructions
 FL33230_R6_II_PAC Box Rib 4 details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R6_TR_ASTM E-1592_Box Rib_4 x .032 (min.) Alum with clip and loads.pdf
 FL33230_R6_TR_PAC Box Rib 4 x 0.032 Alum w Clip ASTM 1592 Summary Load Table.pdf
33230.14 Box Rib 4 (A8) 12" Wide x 24 Ga. (min.) Steel w/Clip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-105.2
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -105.2 @ 2‘, -95.0 @ 2.5‘, -84.8 @ 3‘, -74.5 @ 3.5‘, -64.3 @ 4’, -54.0 @ 4.5‘, -43.7 @ 5‘. Not for use in HVHZ.
Installation Instructions
 FL33230_R6_II_PAC Box Rib 4 details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R6_TR_ASTM E-1592_Box Rib_4 x 24 GA (min.) Steel with clip and loads.pdf
 FL33230_R6_TR_PAC Box Rib 4 x 24 GA w Clip ASTM 1592 Summary Load Table.pdf
33230.15 Modular AL (050) 3" deep x 24" wide x 0.050" (min.) Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-57.2
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -57.2 @ (24") 2.0'. Not for use in HVHZ.
Installation Instructions
 FL33230_R6_II_PAC Modular AL details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R6_TR_ASTM E1592_3 in deep x 24 in x 0.050 in (min.) Aluminum.pdf
33230.16 Modular AL (080) 3" deep x 30" wide x 0.080" (min.) Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-57.2
 Other: Allowable Wind Uplift Pressure, psf. Panel Span, ft: -57.2 @ (30") 2.5'. Not for use in HVHZ.
Installation Instructions
 FL33230_R6_II_PAC Modular AL details.pdf
 Verified By: Farabaugh Engineering and Testing, Inc.
Test Reports
 FL33230_R6_TR_ASTM E1592_3 in deep x 30 in x 0.080 in (min.) Aluminum.pdf
 