31652.1 |
01: 50ALLV 5V Crimp 26ga |
50ALLV 5V Crimp panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-206 Other: 206psf with 12"-12" pattern @ 8" oc, 117.75psf @ 16" |
Installation Instructions FL31652_R4_II_26ga_5V_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31652_R4_AE_26ga_5V_plywood.pdf Created by Independent Third Party: Yes |
|
31652.2 |
02: 50ALLV 5V Crimp 032 Aluminum |
50ALLV 5V Crimp panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-183.5 Other: 183.5psf with 12"-12" pattern @ 12" oc, 116.25psf @ 16" oc |
Installation Instructions FL31652_R4_II_32Al_5V_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31652_R4_AE_32Al_5V_plywood.pdf Created by Independent Third Party: Yes |
|
31652.3 |
03: 50ALLV 5V Crimp 26ga |
50ALLV 5V Crimp panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-206 Other: 206psf with 12"-12" pattern @ 8" oc, 101psf @ 16" oc |
Installation Instructions FL31652_R4_II_26ga_5V_plywood-nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31652_R4_AE_26ga_5V_plywood-nonHVHZ.pdf Created by Independent Third Party: Yes |
|
31652.4 |
04: 50ALLV 5V Crimp 032 Aluminum |
50ALLV 5V Crimp panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-183.5 Other: 183.5psf with 12"-12" pattern @ 12" oc |
Installation Instructions FL31652_R4_II_32Al_5V_plywood-nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31652_R4_AE_32Al_5V_plywood-nonHVHZ.pdf Created by Independent Third Party: Yes |
|
31652.5 |
05: 50ALLCOR Corrugated 26ga |
50ALLCOR 0.75" Corrugated panels from 26ga(min) on 2x4 (nom) battens |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161 Other: 161psf with fastener every peak, 101psf with fastener every other peak, battens @ 24" |
Installation Instructions FL31652_R4_II_26ga_50AllCor_battens-nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31652_R4_AE_26ga_50AllCor_battens-nonHVHZ.pdf Created by Independent Third Party: Yes |
|
31652.6 |
06: 50ALLCOR Corrugated 26ga |
50ALLCOR 0.75" Corrugated panels from 26ga(min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161 Other: 161psf with fastener every other peak @ 12" oc, 101 psf @ 16"oc |
Installation Instructions FL31652_R4_II_26ga_50AllCor_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31652_R4_AE_26ga_50AllCor_plywood.pdf Created by Independent Third Party: Yes |
|
31652.7 |
07: 50ALLRIB Rib 26ga |
50ALLRIB Trapezoidal Rib panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 Other: See report for details |
Installation Instructions FL31652_R4_II_26ga_50AllRib_plywood im.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31652_R4_AE_26ga_50AllRib_plywood im.pdf Created by Independent Third Party: Yes |
|
31652.8 |
08: 50ALLRIB Rib 26ga |
50ALLRIB Trapezoidal Rib panel from 26ga (min) on 17/32" (min) OSB, plywood, or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 Other: See report for details |
Installation Instructions FL31652_R4_II_26ga_50AllRib_OSB im.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31652_R4_AE_26ga_50AllRib_OSB im.pdf Created by Independent Third Party: Yes |
|
31652.9 |
09: 50ALLV 5V Crimp 26ga |
50ALLV 5V Crimp panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116 Other: See report for details |
Installation Instructions FL31652_R4_II_26ga_5V_plywood im.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31652_R4_AE_26ga_5V_plywood im.pdf Created by Independent Third Party: Yes |