Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL1616-R14
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Versico Roofing Systems
Address/Phone/Email P.O. Box 1289
Carlisle, PA 17013
(800) 992-7663
robert.patton@carlisleccm.com
 
Authorized Signature Robert Patton
robert.patton@carlisleccm.com
 
Technical Representative Robert Patton
Address/Phone/Email 1555 Ritner Highway
Carlisle, PA 17013
(717) 245-7264
Robert.PATTON@syntec.carlisle.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Single Ply Roof Systems
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Robert J.M. Nieminen
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/06/2025
Validated By John W. Knezevich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL1616_R14_COI_2023_07_COI_NIEMINEN.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM D46372015
ASTM G1552013
FM 44702016
FM 44742011
TAS 1142011
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 09/21/2023
Date Validated 09/29/2023
Date Pending FBC Approval 10/02/2023
Date Approved 12/12/2023
 
Summary of Products
FL # Model, Number or Name Description
1616.1 Versico EPDM Single Ply Roof System (NON-HVHZ) EPDM single ply roof systems for use in FBC non-HVHZ jurisdictions.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-495.0
 Other: 1.) The design pressure noted in this application pertains to one assembly. Refer to PEER Appendix for all assemblies and max. design pressures. 2.) Refer to PEER Section 5 for Limits of Use.
Installation Instructions
 FL1616_R14_II_2023_09_21_FINAL_A1_PEER-VRS-001.A_NON-HVHZ_FL1616-R14.pdf
 Verified By: Robert J. M. Nieminen PE - 59166
 Created by Independent Third Party: Yes
Evaluation Reports
 FL1616_R14_AE_2023_09_21_FINAL_PEER-VRS-001.A_NON-HVHZ_FL1616-R14.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe