Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL40241-R1
Application Type Affirmation
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Velux America, LLC
Address/Phone/Email P.O. Box 5001
Greenwood, SC 29648
(864) 377-0691
Mike.rhoden@velux.com
 
Authorized Signature Mike Rhoden
Mike.rhoden@velux.com
 
Technical Representative Mike Rhoden
Address/Phone/Email 104 Ben Casey Dr
Fort Mill, SC 29708
(864) 377-0691
mike.rhoden@velux.com
 
Quality Assurance Representative Mike Dorn
Address/Phone/Email P.O. Box 5001
Greenwood, SC 29648-5001
(864) 941-4700
mike.dorn@velux.com
 
Category Sky Lights
Subcategory Skylight
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A4402017
AAMA/WDMA/CSA 101/I.S.2/A4402011
ASTM E 18862013
ASTM E 19962014
 
Equivalence of Product Standards
Certified By

 
 
 
Documentation from approved Evaluation or Validation Entity
 
FL40241_R1_COC_FL 40241 COMP.pdf
 
Product Approval Method Method 1 Option A
 
Date Submitted 07/13/2023
Date Validated 07/13/2023
Date Pending FBC Approval
Date Approved 07/16/2023
 
Summary of Products
FL # Model, Number or Name Description
40241.1 VELUX VMS Fixed Longlight HFC fixed module size 1000mm x 3000mm or smaller (426-H-728.00/.01)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +60/-100
 Other: SKG-PG60, Design Press. +60/-100, max size 1000mm x 3000mm (39.4" x 118.1"). Glass makeup: 8mm (0.315") thick heat strengthened tempered exterior / 16mm st. stl. spacer with Argon gas infill and LowE / 10mm laminate interior using two 5mm (0.197") thick heat strengthened panes and .76mm (0.030") PVB interlayer. Details for anchoring to site-built curb in installation instructions.
Certification Agency Certificate
 FL40241_R1_C_CAC_Longlight HFC 100300 or smaller (non-impact).pdf
Quality Assurance Contract Expiration Date
 07/30/2030
Installation Instructions
 FL40241_R1_II_VMS Longlight Install Instructions.pdf
 FL40241_R1_II_VMS Longlight Subconstruction Install Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
40241.2 VELUX VMS Fixed Longlight (Impact) HFC fixed module (Impact) size 1000mm x 3000mm or smaller (426-H-728.00/.01/.09)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: SKG-PG60, Wind Zone 3, Missile Level C, Design Press. +60/-100, Cycle Press. +50/-50, max size 1000mm x 3000mm (39.4" x 118.1"). Tested ASTM E1886/ASTM E1996. Glass makeup: 8mm (0.315") thick heat strengthened tempered exterior / 16mm st. stl. spacer with Argon gas infill and LowE / 10mm laminate interior using two 5mm (0.197") thick heat strengthened panes and 2.28mm (0.090") PVB interlayer. Details for anchoring to site-built curb in installation instructions.
Certification Agency Certificate
 FL40241_R1_C_CAC_Longlight HFC 100300 or smaller.pdf
Quality Assurance Contract Expiration Date
 07/30/2030
Installation Instructions
 FL40241_R1_II_VMS Longlight Install Instructions.pdf
 FL40241_R1_II_VMS Longlight Subconstruction Install Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
40241.3 VELUX VMS Fixed Northlight HFC fixed module size 1000mm x 3000mm or smaller (426-H-728.18/.19)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +75/-100
 Other: SKG-PG75, Design Press. +75/-100, max size 1000mm x 3000mm (39.4" x 118.1"). Glass makeup: 8mm (0.315") thick heat strengthened tempered exterior / 16mm st. stl. spacer with Argon gas infill and LowE / 10mm laminate interior using two 5mm (0.197") thick heat strengthened panes and .76mm (0.030") PVB interlayer. Details for anchoring to site-built curb in installation instructions.
Certification Agency Certificate
 FL40241_R1_C_CAC_Northlight HFC 100300 or smaller (non-impact).pdf
Quality Assurance Contract Expiration Date
 12/19/2027
Installation Instructions
 FL40241_R1_II_VMS Northlight Install Instructions.pdf
 FL40241_R1_II_VMS Northlight Subconstruction Install Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
40241.4 VELUX VMS Fixed Northlight (Impact) HFC fixed module (Impact) size 1000mm x 3000mm or smaller (426-H-728.18/.19/.09)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: SKG-PG75, Wind Zone 3, Missile Level C, Design Press. +75/-100, Cycle Press. +50/-50, max size 1000mm x 3000mm (39.4" x 118.1"). Tested ASTM E1886/ASTM E1996. Glass makeup: 8mm (0.315") thick heat strengthened tempered exterior / 16mm st. stl. spacer with Argon gas infill and LowE / 10mm laminate interior using two 5mm (0.197") thick heat strengthened panes and 2.28mm (0.090") PVB interlayer. Details for anchoring to site-built curb in installation instructions.
Certification Agency Certificate
 FL40241_R1_C_CAC_Northlight HFC 100300 or smaller.pdf
Quality Assurance Contract Expiration Date
 12/19/2027
Installation Instructions
 FL40241_R1_II_VMS Northlight Install Instructions.pdf
 FL40241_R1_II_VMS Northlight Subconstruction Install Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
40241.5 VELUX VMS Fixed Ridgelight HFC fixed module size 1000mm x 2400mm or smaller (426-H-728.10/.11)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +70/-50
 Other: SKG-PG50, Design Press. +70/-50, max size 1000mm x 2400mm (39.4" x 94.5"). Glass makeup: 6mm (0.236") thick heat strengthened tempered exterior / 20mm st. stl. spacer with Argon gas infill and LowE / 6mm laminate interior using two 3mm (0.118") thick heat strengthened panes and .76mm (0.030") PVB interlayer. Details for anchoring to site-built curb in installation instructions.
Certification Agency Certificate
 FL40241_R1_C_CAC_Ridgelight HFC 100240 or smaller (non-impact).pdf
Quality Assurance Contract Expiration Date
 08/10/2030
Installation Instructions
 FL40241_R1_II_VMS Ridgelight Install Instructions.pdf
 FL40241_R1_II_VMS Ridgelight Subconstruction Install Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
40241.6 VELUX VMS Fixed Ridgelight (Impact) HFC fixed module (Impact) size 1000mm x 2400mm or smaller (426-H-728.10/.11/.09)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: SKG-PG50, Wind Zone 3, Missile Level C, Design Press. +70/-50, Cycle Press. +50/-50, max size 1000mm x 2400mm (39.4" x 94.5"). Tested ASTM E1886/ASTM E1996. Glass makeup: 8mm (0.315") thick heat strengthened tempered exterior / 16mm st. stl. spacer with Argon gas infill and LowE / 10mm laminate interior using two 5mm (0.197") thick heat strengthened panes and 2.28mm (0.090") PVB interlayer. Details for anchoring to site-built curb in installation instructions.
Certification Agency Certificate
 FL40241_R1_C_CAC_Ridgelight HVC 100240 or smaller.pdf
Quality Assurance Contract Expiration Date
 08/10/2030
Installation Instructions
 FL40241_R1_II_VMS Ridgelight Install Instructions.pdf
 FL40241_R1_II_VMS Ridgelight Subconstruction Install Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
40241.7 VELUX VMS Venting Longlight HVC venting module size 1000mm x 2400mm or smaller (426-H-728.04/.05)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +95/-50
 Other: SKG-PG50, Design Press. +95/-50, max size 1000mm x 2400mm (39.4" x 94.5"). Glass makeup: 6mm (0.236") thick heat strengthened tempered exterior / 20mm st. stl. spacer with Argon gas infill and LowE / 6mm laminate interior using two 3mm (0.118") thick heat strengthened panes and .76mm (0.030") PVB interlayer. Details for anchoring to site-built curb in installation instructions.
Certification Agency Certificate
 FL40241_R1_C_CAC_Longlight HVC 100240 or smaller (non-impact).pdf
Quality Assurance Contract Expiration Date
 07/31/2030
Installation Instructions
 FL40241_R1_II_VMS Longlight Install Instructions.pdf
 FL40241_R1_II_VMS Longlight Subconstruction Install Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
40241.8 VELUX VMS Venting Longlight (Impact) HVC venting module (Impact) size 1000mm x 2400mm or smaller (426-H-728.04/.05/.08)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: SKG-PG50, Wind Zone 3, Missile Level C, Design Press. +95/-50, Cycle Press. +50/-50, max size 1000mm x 2400mm (39.4" x 94.5"). Tested ASTM E1886/ASTM E1996. Glass makeup: 8mm (0.315") thick heat strengthened tempered exterior / 16mm st. stl. spacer with Argon gas infill and LowE / 10mm laminate interior using two 5mm (0.197") thick heat strengthened panes and 2.28mm (0.090") PVB interlayer. Details for anchoring to site-built curb in installation instructions.
Certification Agency Certificate
 FL40241_R1_C_CAC_Ridgelight HVC 100240 or smaller.pdf
Quality Assurance Contract Expiration Date
 07/31/2030
Installation Instructions
 FL40241_R1_II_VMS Longlight Install Instructions.pdf
 FL40241_R1_II_VMS Longlight Subconstruction Install Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
40241.9 VELUX VMS Venting Ridgelight HVC venting module size 1000mm x 2400mm or smaller (426-H-728.14/.15)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +70/-50
 Other: SKG-PG50, Design Press. +70/-50, max size 1000mm x 2400mm (39.4" x 94.5"). Glass makeup: 6mm (0.236") thick heat strengthened tempered exterior / 20mm st. stl. spacer with Argon gas infill and LowE / 6mm laminate interior using two 3mm (0.118") thick heat strengthened panes and .76mm (0.030") PVB interlayer. Details for anchoring to site-built curb in installation instructions.
Certification Agency Certificate
 FL40241_R1_C_CAC_Ridgelight HVC 100240 or smaller (non-impact).pdf
Quality Assurance Contract Expiration Date
 08/10/2030
Installation Instructions
 FL40241_R1_II_VMS Ridgelight Install Instructions.pdf
 FL40241_R1_II_VMS Ridgelight Subconstruction Install Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
40241.10 VELUX VMS Venting Ridgelight (Impact) HVC venting module (Impact) size 1000mm x 2400mm or smaller (426-H-728.14/.15/.08)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: SKG-PG50, Wind Zone 3, Missile Level C, Design Press. +70/-50, Cycle Press. +50/-50, max size 1000mm x 2400mm (39.4" x 94.5"). Tested ASTM E1886/ASTM E1996. Glass makeup: 8mm (0.315") thick heat strengthened tempered exterior / 16mm st. stl. spacer with Argon gas infill and LowE / 10mm laminate interior using two 5mm (0.197") thick heat strengthened panes and 2.28mm (0.090") PVB interlayer. Details for anchoring to site-built curb in installation instructions.
Certification Agency Certificate
 FL40241_R1_C_CAC_Ridgelight HVC 100240 or smaller.pdf
Quality Assurance Contract Expiration Date
 08/10/2030
Installation Instructions
 FL40241_R1_II_VMS Ridgelight Install Instructions.pdf
 FL40241_R1_II_VMS Ridgelight Subconstruction Install Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts: