40241.1 |
VELUX VMS Fixed Longlight |
HFC fixed module size 1000mm x 3000mm or smaller (426-H-728.00/.01) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-100 Other: SKG-PG60, Design Press. +60/-100, max size 1000mm x 3000mm (39.4" x 118.1"). Glass makeup: 8mm (0.315") thick heat strengthened tempered exterior / 16mm st. stl. spacer with Argon gas infill and LowE / 10mm laminate interior using two 5mm (0.197") thick heat strengthened panes and .76mm (0.030") PVB interlayer. Details for anchoring to site-built curb in installation instructions. |
Certification Agency Certificate FL40241_R1_C_CAC_Longlight HFC 100300 or smaller (non-impact).pdf Quality Assurance Contract Expiration Date 07/30/2030 Installation Instructions FL40241_R1_II_VMS Longlight Install Instructions.pdf FL40241_R1_II_VMS Longlight Subconstruction Install Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
40241.2 |
VELUX VMS Fixed Longlight (Impact) |
HFC fixed module (Impact) size 1000mm x 3000mm or smaller (426-H-728.00/.01/.09) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: SKG-PG60, Wind Zone 3, Missile Level C, Design Press. +60/-100, Cycle Press. +50/-50, max size 1000mm x 3000mm (39.4" x 118.1"). Tested ASTM E1886/ASTM E1996. Glass makeup: 8mm (0.315") thick heat strengthened tempered exterior / 16mm st. stl. spacer with Argon gas infill and LowE / 10mm laminate interior using two 5mm (0.197") thick heat strengthened panes and 2.28mm (0.090") PVB interlayer. Details for anchoring to site-built curb in installation instructions. |
Certification Agency Certificate FL40241_R1_C_CAC_Longlight HFC 100300 or smaller.pdf Quality Assurance Contract Expiration Date 07/30/2030 Installation Instructions FL40241_R1_II_VMS Longlight Install Instructions.pdf FL40241_R1_II_VMS Longlight Subconstruction Install Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
40241.3 |
VELUX VMS Fixed Northlight |
HFC fixed module size 1000mm x 3000mm or smaller (426-H-728.18/.19) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +75/-100 Other: SKG-PG75, Design Press. +75/-100, max size 1000mm x 3000mm (39.4" x 118.1"). Glass makeup: 8mm (0.315") thick heat strengthened tempered exterior / 16mm st. stl. spacer with Argon gas infill and LowE / 10mm laminate interior using two 5mm (0.197") thick heat strengthened panes and .76mm (0.030") PVB interlayer. Details for anchoring to site-built curb in installation instructions. |
Certification Agency Certificate FL40241_R1_C_CAC_Northlight HFC 100300 or smaller (non-impact).pdf Quality Assurance Contract Expiration Date 12/19/2027 Installation Instructions FL40241_R1_II_VMS Northlight Install Instructions.pdf FL40241_R1_II_VMS Northlight Subconstruction Install Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
40241.4 |
VELUX VMS Fixed Northlight (Impact) |
HFC fixed module (Impact) size 1000mm x 3000mm or smaller (426-H-728.18/.19/.09) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: SKG-PG75, Wind Zone 3, Missile Level C, Design Press. +75/-100, Cycle Press. +50/-50, max size 1000mm x 3000mm (39.4" x 118.1"). Tested ASTM E1886/ASTM E1996. Glass makeup: 8mm (0.315") thick heat strengthened tempered exterior / 16mm st. stl. spacer with Argon gas infill and LowE / 10mm laminate interior using two 5mm (0.197") thick heat strengthened panes and 2.28mm (0.090") PVB interlayer. Details for anchoring to site-built curb in installation instructions. |
Certification Agency Certificate FL40241_R1_C_CAC_Northlight HFC 100300 or smaller.pdf Quality Assurance Contract Expiration Date 12/19/2027 Installation Instructions FL40241_R1_II_VMS Northlight Install Instructions.pdf FL40241_R1_II_VMS Northlight Subconstruction Install Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
40241.5 |
VELUX VMS Fixed Ridgelight |
HFC fixed module size 1000mm x 2400mm or smaller (426-H-728.10/.11) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-50 Other: SKG-PG50, Design Press. +70/-50, max size 1000mm x 2400mm (39.4" x 94.5"). Glass makeup: 6mm (0.236") thick heat strengthened tempered exterior / 20mm st. stl. spacer with Argon gas infill and LowE / 6mm laminate interior using two 3mm (0.118") thick heat strengthened panes and .76mm (0.030") PVB interlayer. Details for anchoring to site-built curb in installation instructions. |
Certification Agency Certificate FL40241_R1_C_CAC_Ridgelight HFC 100240 or smaller (non-impact).pdf Quality Assurance Contract Expiration Date 08/10/2030 Installation Instructions FL40241_R1_II_VMS Ridgelight Install Instructions.pdf FL40241_R1_II_VMS Ridgelight Subconstruction Install Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
40241.6 |
VELUX VMS Fixed Ridgelight (Impact) |
HFC fixed module (Impact) size 1000mm x 2400mm or smaller (426-H-728.10/.11/.09) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: SKG-PG50, Wind Zone 3, Missile Level C, Design Press. +70/-50, Cycle Press. +50/-50, max size 1000mm x 2400mm (39.4" x 94.5"). Tested ASTM E1886/ASTM E1996. Glass makeup: 8mm (0.315") thick heat strengthened tempered exterior / 16mm st. stl. spacer with Argon gas infill and LowE / 10mm laminate interior using two 5mm (0.197") thick heat strengthened panes and 2.28mm (0.090") PVB interlayer. Details for anchoring to site-built curb in installation instructions. |
Certification Agency Certificate FL40241_R1_C_CAC_Ridgelight HVC 100240 or smaller.pdf Quality Assurance Contract Expiration Date 08/10/2030 Installation Instructions FL40241_R1_II_VMS Ridgelight Install Instructions.pdf FL40241_R1_II_VMS Ridgelight Subconstruction Install Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
40241.7 |
VELUX VMS Venting Longlight |
HVC venting module size 1000mm x 2400mm or smaller (426-H-728.04/.05) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +95/-50 Other: SKG-PG50, Design Press. +95/-50, max size 1000mm x 2400mm (39.4" x 94.5"). Glass makeup: 6mm (0.236") thick heat strengthened tempered exterior / 20mm st. stl. spacer with Argon gas infill and LowE / 6mm laminate interior using two 3mm (0.118") thick heat strengthened panes and .76mm (0.030") PVB interlayer. Details for anchoring to site-built curb in installation instructions. |
Certification Agency Certificate FL40241_R1_C_CAC_Longlight HVC 100240 or smaller (non-impact).pdf Quality Assurance Contract Expiration Date 07/31/2030 Installation Instructions FL40241_R1_II_VMS Longlight Install Instructions.pdf FL40241_R1_II_VMS Longlight Subconstruction Install Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
40241.8 |
VELUX VMS Venting Longlight (Impact) |
HVC venting module (Impact) size 1000mm x 2400mm or smaller (426-H-728.04/.05/.08) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: SKG-PG50, Wind Zone 3, Missile Level C, Design Press. +95/-50, Cycle Press. +50/-50, max size 1000mm x 2400mm (39.4" x 94.5"). Tested ASTM E1886/ASTM E1996. Glass makeup: 8mm (0.315") thick heat strengthened tempered exterior / 16mm st. stl. spacer with Argon gas infill and LowE / 10mm laminate interior using two 5mm (0.197") thick heat strengthened panes and 2.28mm (0.090") PVB interlayer. Details for anchoring to site-built curb in installation instructions. |
Certification Agency Certificate FL40241_R1_C_CAC_Ridgelight HVC 100240 or smaller.pdf Quality Assurance Contract Expiration Date 07/31/2030 Installation Instructions FL40241_R1_II_VMS Longlight Install Instructions.pdf FL40241_R1_II_VMS Longlight Subconstruction Install Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
40241.9 |
VELUX VMS Venting Ridgelight |
HVC venting module size 1000mm x 2400mm or smaller (426-H-728.14/.15) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-50 Other: SKG-PG50, Design Press. +70/-50, max size 1000mm x 2400mm (39.4" x 94.5"). Glass makeup: 6mm (0.236") thick heat strengthened tempered exterior / 20mm st. stl. spacer with Argon gas infill and LowE / 6mm laminate interior using two 3mm (0.118") thick heat strengthened panes and .76mm (0.030") PVB interlayer. Details for anchoring to site-built curb in installation instructions. |
Certification Agency Certificate FL40241_R1_C_CAC_Ridgelight HVC 100240 or smaller (non-impact).pdf Quality Assurance Contract Expiration Date 08/10/2030 Installation Instructions FL40241_R1_II_VMS Ridgelight Install Instructions.pdf FL40241_R1_II_VMS Ridgelight Subconstruction Install Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
40241.10 |
VELUX VMS Venting Ridgelight (Impact) |
HVC venting module (Impact) size 1000mm x 2400mm or smaller (426-H-728.14/.15/.08) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: SKG-PG50, Wind Zone 3, Missile Level C, Design Press. +70/-50, Cycle Press. +50/-50, max size 1000mm x 2400mm (39.4" x 94.5"). Tested ASTM E1886/ASTM E1996. Glass makeup: 8mm (0.315") thick heat strengthened tempered exterior / 16mm st. stl. spacer with Argon gas infill and LowE / 10mm laminate interior using two 5mm (0.197") thick heat strengthened panes and 2.28mm (0.090") PVB interlayer. Details for anchoring to site-built curb in installation instructions. |
Certification Agency Certificate FL40241_R1_C_CAC_Ridgelight HVC 100240 or smaller.pdf Quality Assurance Contract Expiration Date 08/10/2030 Installation Instructions FL40241_R1_II_VMS Ridgelight Install Instructions.pdf FL40241_R1_II_VMS Ridgelight Subconstruction Install Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |