11560.1 |
Aluminum 5V-Crimp |
24" wide, nom 0.032" thick aluminum through fastened roof panel over min 15/32” thick plywood deck or 7/16" thick OSB with fasteners through panel rib. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-222.3 Other: Uplift load of 222.3 psf at fastener spacing of 3" o.c. |
Installation Instructions FL11560_R5_II_EvaluationReportC2672_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL11560_R5_AE_EvaluationReportC2672_1.pdf Created by Independent Third Party: Yes |
|
11560.2 |
Aluminum Image II |
16" wide, nom 0.032" thick aluminum concealed fastener roof panel over min 15/32” thick plywood deck or 7/16" thick OSB. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-206 Other: Uplift load of 206 psf at fastener spacing of 6" o.c. with sidelap adhesive and support strap. |
Installation Instructions FL11560_R5_II_EvaluationReportC2672_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL11560_R5_AE_EvaluationReportC2672_2.pdf Created by Independent Third Party: Yes |
|
11560.3 |
Aluminum Image II |
16" wide, nom 0.032" thick aluminum concealed fastener roof panel over min 15/32” thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-222.3 Other: Uplift load of 222.3 psf at fastener spacing of 6" o.c. with support strap. |
Installation Instructions FL11560_R5_II_EvaluationReportC2672_3.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL11560_R5_AE_EvaluationReportC2672_3.pdf Created by Independent Third Party: Yes |
|
11560.4 |
Image II |
16" wide, min. 26 ga. concealed fastener roof panel over min. 15/32" thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-222 Other: Uplift load of 222 psf at fastener spacing of 6" o.c. with support strap |
Installation Instructions FL11560_R5_II_EvaluationReportC2672_4.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL11560_R5_AE_EvaluationReportC2672_4.pdf Created by Independent Third Party: Yes |
|
11560.5 |
Magna-Loc |
Max. 16" wide, min. 24 ga. standing seam roof panel over plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-166 Other: Uplift load of 166 psf @ MPW clip spacing of 12" o.c. |
Installation Instructions FL11560_R5_II_EvaluationReportC2672_5.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL11560_R5_AE_EvaluationReportC2672_5.pdf Created by Independent Third Party: Yes |
|
11560.6 |
Magna-Loc |
Max. 16" wide, min. 24 ga. standing seam roof panel over steel deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.5 Other: Uplift load of 168.5 psf @ MPW clip spacing of 12" o.c. |
Installation Instructions FL11560_R5_II_EvaluationReportC2672_6.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL11560_R5_AE_EvaluationReportC2672_6.pdf Created by Independent Third Party: Yes |
|
11560.7 |
Vertical Seam |
Max. 16" wide, min. 24 ga. standing seam roof panel over min. 15/32" thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-200 Other: Uplift load of 200.0 psf at clip spacing of 12" o.c. with support strap and adhesive |
Installation Instructions FL11560_R5_II_EvaluationReportC2672_7.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL11560_R5_AE_EvaluationReportC2672_7.pdf Created by Independent Third Party: Yes |
|
11560.8 |
Vertical Seam |
Max. 18" wide, min. 24 ga. standing seam roof panel over min. 15/32" thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-105.0 Other: Uplift load of 105.0 psf at clip spacing of 12" o.c. with sidelap adhesive. |
Installation Instructions FL11560_R5_II_EvaluationReportC2672_8.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL11560_R5_AE_EvaluationReportC2672_8.pdf Created by Independent Third Party: Yes |
|
11560.9 |
Vertical Seam |
Max. 16" wide, min. 26 ga. standing seam roof panel over min. 15/32" thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-81.3 Other: Uplift load of 81.3 psf at clip spacing of 6" o.c. |