FL # FL15442-R6
Application Type Affirmation
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Jeld-Wen
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls, OR 97601
(541) 850-2650
rfricks@jeldwen.com
 
Authorized Signature Rylee Fricks
rfricks@jeldwen.com
 
Technical Representative JELD-WEN Corporate Customer Service
Address/Phone/Email 3737 Lakeport Blvd.
Klamath Falls, OR 97601
(800) 535-3936
customerserviceagents@jeld-wen.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Windows
Subcategory Fixed
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Hermes F. Norero, P.E.
Florida License PE-73778
Quality Assurance Entity Window and Door Manufacturers Association-QA
Quality Assurance Contract Expiration Date 12/22/2024
Validated By Locke Bowden P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL15442_R6_COI_COI JW SS 2015-04-27.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
Documentation from approved Evaluation or Validation Entity
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 07/06/2020
Date Validated 07/06/2020
Date Pending FBC Approval
Date Approved 07/14/2020
Date Revised 07/10/2023
 
Summary of Products
FL # Model, Number or Name Description
15442.1 Custom Clad (A) Casement Fixed 60" x 72" Insulated Glass (5/16 in PVB LAM - 1/8 out Annealed) or (3/8 in SGP Lam - 5/32 out Tempered)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +60/-70
 Other:  
Installation Instructions
 FL15442_R6_II_JW013_Installation.pdf
 Verified By: Hermes F. Norero, P.E. # 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15442_R6_AE_PER2855.pdf
 Created by Independent Third Party: Yes
15442.2 Custom Clad (B) Casement Fixed 96" x 72" Single Glaze (9/16 in SGP LAM) or Insulated Glass (9/16 in SGP Lam - 1/4 out Annealed) or (9/16 in SGP Lam - 1/4 out Tempered)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +60/-65
 Other:  
Installation Instructions
 FL15442_R6_II_JW013_Installation.pdf
 Verified By: Hermes F. Norero, P.E. # 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15442_R6_AE_PER2855.pdf
 Created by Independent Third Party: Yes
15442.3 Custom Clad (C) Direct Set Fixed 48" x 120" Single Glaze (9/16 in Heat Strengthened SGP LAM) or Insulated Glass (1/2 in Heat Strengthened SGP LAM - 3/16 out Tempered)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +100/-100
 Other:  
Installation Instructions
 FL15442_R6_II_JW026_Installation.pdf
 Verified By: Hermes F. Norero, P.E. # 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15442_R6_AE_PER2856.pdf
 Created by Independent Third Party: Yes
15442.4 Custom Clad (D) Direct Set Fixed 60" x 120" Single Glaze (9/16 in Heat Strengthened SGP LAM) or Insulated Glass (9/16 in SGP LAM - 1/4 out Annealed) or (9/16 in SGP LAM - 1/4 out Tempered)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +80/-80
 Other:  
Installation Instructions
 FL15442_R6_II_JW026_Installation.pdf
 Verified By: Hermes F. Norero, P.E. # 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15442_R6_AE_PER2856.pdf
 Created by Independent Third Party: Yes
15442.5 Custom Clad (E) Direct Set Fixed 96" x 72" Single Glaze (9/16 in SGP LAM) or Insulated Glass (9/16 in SGP LAM - 1/4 out Annealed) or (9/16 in SGP LAM - 1/4 out Tempered) or (5/16 in PVB LAM - 1/8 out Annealed)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +60/-65
 Other:  
Installation Instructions
 FL15442_R6_II_JW026_Installation.pdf
 Verified By: Hermes F. Norero, P.E. # 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15442_R6_AE_PER2856.pdf
 Created by Independent Third Party: Yes
15442.6 Custom Clad (F) Insash Geometric Fixed 96" x 72" Single Glaze (9/16 in SGP LAM) or Insulated Glass (5/16 in SGP LAM - 1/4 out Annealed) or (5/16 in SGP LAM - 1/4 out Tempered)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +60/-65
 Other:  
Installation Instructions
 FL15442_R6_II_JW014_Installation.pdf
 Verified By: Hermes F. Norero, P.E. # 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15442_R6_AE_PER2857.pdf
 Created by Independent Third Party: Yes
15442.7 Custom Clad (G) Insash Geometric Fixed 60" x 72" Insulated Glass (3/8 in SGP LAM and 5/32 out Tempered) or (5/16 in PVB LAM - 1/8 out Annealed )
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +60/-70
 Other:  
Installation Instructions
 FL15442_R6_II_JW014_Installation.pdf
 Verified By: Hermes F. Norero, P.E. # 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15442_R6_AE_PER2857.pdf
 Created by Independent Third Party: Yes
 