| 15442.1 |
Custom Clad (A) |
Casement Fixed 60" x 72" Insulated Glass (5/16 in PVB LAM - 1/8 out Annealed) or (3/8 in SGP Lam - 5/32 out Tempered) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-70 Other: |
Installation Instructions FL15442_R6_II_JW013_Installation.pdf Verified By: Hermes F. Norero, P.E. # 73778 Created by Independent Third Party: Yes Evaluation Reports FL15442_R6_AE_PER2855.pdf Created by Independent Third Party: Yes |
|
|
| 15442.2 |
Custom Clad (B) |
Casement Fixed 96" x 72" Single Glaze (9/16 in SGP LAM) or Insulated Glass (9/16 in SGP Lam - 1/4 out Annealed) or (9/16 in SGP Lam - 1/4 out Tempered) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-65 Other: |
Installation Instructions FL15442_R6_II_JW013_Installation.pdf Verified By: Hermes F. Norero, P.E. # 73778 Created by Independent Third Party: Yes Evaluation Reports FL15442_R6_AE_PER2855.pdf Created by Independent Third Party: Yes |
|
|
| 15442.3 |
Custom Clad (C) |
Direct Set Fixed 48" x 120" Single Glaze (9/16 in Heat Strengthened SGP LAM) or Insulated Glass (1/2 in Heat Strengthened SGP LAM - 3/16 out Tempered) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +100/-100 Other: |
Installation Instructions FL15442_R6_II_JW026_Installation.pdf Verified By: Hermes F. Norero, P.E. # 73778 Created by Independent Third Party: Yes Evaluation Reports FL15442_R6_AE_PER2856.pdf Created by Independent Third Party: Yes |
|
|
| 15442.4 |
Custom Clad (D) |
Direct Set Fixed 60" x 120" Single Glaze (9/16 in Heat Strengthened SGP LAM) or Insulated Glass (9/16 in SGP LAM - 1/4 out Annealed) or (9/16 in SGP LAM - 1/4 out Tempered) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +80/-80 Other: |
Installation Instructions FL15442_R6_II_JW026_Installation.pdf Verified By: Hermes F. Norero, P.E. # 73778 Created by Independent Third Party: Yes Evaluation Reports FL15442_R6_AE_PER2856.pdf Created by Independent Third Party: Yes |
|
|
| 15442.5 |
Custom Clad (E) |
Direct Set Fixed 96" x 72" Single Glaze (9/16 in SGP LAM) or Insulated Glass (9/16 in SGP LAM - 1/4 out Annealed) or (9/16 in SGP LAM - 1/4 out Tempered) or (5/16 in PVB LAM - 1/8 out Annealed) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-65 Other: |
Installation Instructions FL15442_R6_II_JW026_Installation.pdf Verified By: Hermes F. Norero, P.E. # 73778 Created by Independent Third Party: Yes Evaluation Reports FL15442_R6_AE_PER2856.pdf Created by Independent Third Party: Yes |
|
|
| 15442.6 |
Custom Clad (F) |
Insash Geometric Fixed 96" x 72" Single Glaze (9/16 in SGP LAM) or Insulated Glass (5/16 in SGP LAM - 1/4 out Annealed) or (5/16 in SGP LAM - 1/4 out Tempered) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-65 Other: |
Installation Instructions FL15442_R6_II_JW014_Installation.pdf Verified By: Hermes F. Norero, P.E. # 73778 Created by Independent Third Party: Yes Evaluation Reports FL15442_R6_AE_PER2857.pdf Created by Independent Third Party: Yes |
|
|
| 15442.7 |
Custom Clad (G) |
Insash Geometric Fixed 60" x 72" Insulated Glass (3/8 in SGP LAM and 5/32 out Tempered) or (5/16 in PVB LAM - 1/8 out Annealed ) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-70 Other: |
Installation Instructions FL15442_R6_II_JW014_Installation.pdf Verified By: Hermes F. Norero, P.E. # 73778 Created by Independent Third Party: Yes Evaluation Reports FL15442_R6_AE_PER2857.pdf Created by Independent Third Party: Yes |