FL # FL1046-R11
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Johns Manville
Address/Phone/Email P.O. Box 5108
Denver, CO 80217
(303) 978-4879
Rick.Martelon@JM.com
 
Authorized Signature Martelon Rick
Rick.Martelon@JM.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Modified Bitumen Roof System
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/22/2025
Validated By John W. Knezevich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL1046_R11_COI_2022_01_COI_NIEMINEN.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM D21782015
ASTM D46012012
ASTM D48972009
ASTM D61622015
ASTM D61632015
ASTM D61642011
ASTM D62222011
ASTM D62232009
ASTM D65092015
ASTM G1552013
FM 44702016
FM 44742011
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 06/15/2022
Date Validated 06/15/2022
Date Pending FBC Approval 06/21/2022
Date Approved 08/09/2022
Date Revised 10/22/2023
 
Summary of Products
FL # Model, Number or Name Description
1046.1 Johns Manville APP Modified Bitumen Roof Systems for use in FBC non-HVHZ jurisdictions APP Modified Bitumen Roof Systems
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-315
 Other: 1.) The design pressure noted herein pertains to one specific assembly within the ER. Refer to the ER Appendix for all systems and design pressure limitations. 2.) Refer to ER Section 5 for Limits of Use.
Installation Instructions
 FL1046_R11_II_2022_06_14_FINAL_A1_ER_JM_MODBIT_APP_FL1046-R11.pdf
 Verified By: Robert Nieminen PE-59166
 Created by Independent Third Party: Yes
Evaluation Reports
 FL1046_R11_AE_2022_06_14_FINAL_ER_JM_MODBIT_APP_FL1046-R11.pdf
 Created by Independent Third Party: Yes
 