30343.1 |
01: 26ga 5V Crimp over plywood |
26ga (min) 5V Crimp over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5 Other: 108.5psf with 12"-12" pattern at 12"oc |
Installation Instructions FL30343_R3_II_26ga_5VCrimp_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30343_R3_AE_26ga_5VCrimp_plywood.pdf Created by Independent Third Party: Yes |
|
30343.2 |
02: 26ga PermaShield over plywood |
26ga (min) PermaShield screw strip over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116 Other: 116psf fastener every hole WITH sealant, 71psf fastener every other hole |
Installation Instructions FL30343_R3_II_26ga_PermaShield_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30343_R3_AE_26ga_PermaShield_plywood.pdf Created by Independent Third Party: Yes |
|
30343.3 |
03: 032 Aluminum PermaShield over plywood |
Nominally 032 or thicker aluminum PermaShield screw strip over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5 Other: 153.5 with fastener every hole WITH sealant, 86psf with fastener every hole with OUT sealant. |
Installation Instructions FL30343_R3_II_032Al_PermaShield_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30343_R3_AE_032Al_PermaShield_plywood.pdf Created by Independent Third Party: Yes |
|
30343.4 |
04: 26ga TuffRib over plywood |
26ga (min) TuffRib over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5 Other: 123.5psf with 6.5"-2.5"-6.5"-2.5" fastener pattern @ 12" oc, 82.25psf with 9"-9"-9" fastener pattern @ 24" oc |
Installation Instructions FL30343_R3_II_26ga_TuffRib_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30343_R3_AE_26ga_TuffRib_plywood.pdf Created by Independent Third Party: Yes |
|
30343.5 |
05: 032 Aluminum DuraSeam over plywood |
Nominally 0.032" or thicker aluminum DuraSeam over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5 Other: 108.5 psf with clips @ 18" oc |
Installation Instructions FL30343_R3_II_032Al_DuraSeam_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30343_R3_AE_032Al_DuraSeam_plywood.pdf Created by Independent Third Party: Yes |
|
30343.6 |
06: 26ga DuraSeam over plywood |
26ga (min) DuraSeam over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 Other: 93.5psf with clips @ 12" oc, 63.5psf with clips @ 16" oc |
Installation Instructions FL30343_R3_II_26ga_DuraSeam_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30343_R3_AE_26ga_DuraSeam_plywood.pdf Created by Independent Third Party: Yes |
|
30343.7 |
07: 29ga TuffRib over plywood |
29ga (min) TuffRib over 15/32" (min) plywood | Fastener in the rib |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5 Other: 123.5 psf with 9"-9"-9" fastener pattern @ 12" oc, 56psf @ 24" oc |
Installation Instructions FL30343_R3_II_29ga_TuffRib_Plywood-rib.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30343_R3_AE_29ga_TuffRib_Plywood-rib.pdf Created by Independent Third Party: Yes |
|
30343.8 |
08: 29ga TuffRib on 1x4 battens over plywood |
29ga (min) TuffRib on 1x4 (nom) battens over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131 Other: 131 psf with 9"-9"-9" fastener pattern @ 12" oc, 78.5psf @ 24" oc |
Installation Instructions FL30343_R3_II_29ga_TuffRib_1x4.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30343_R3_AE_29ga_TuffRib_1x4.pdf Created by Independent Third Party: Yes |
|
30343.9 |
09: 29ga TuffRib over plywood |
29ga (min) TuffRib over 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 Other: 93.5 psf with 9"-9"-9" fastener pattern @ 12" oc, 56psf @ 24" oc |
Installation Instructions FL30343_R3_II_29ga_TuffRib_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL30343_R3_AE_29ga_TuffRib_plywood.pdf Created by Independent Third Party: Yes |