Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL41919-R0
Application Type New
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer MFM Building Products Corp.
Address/Phone/Email 525 Orange St.
P.O. Box 340
Coshocton, OH 43812
(740) 622-2645
wcroft@mfmbp.com
 
Authorized Signature James Buckner
jimmy@cbuckinc.net
 
Technical Representative Whit Croft
Address/Phone/Email 525 Orange Street
Cochocton, OH 43812
(740) 622-2645
wcroft@mfmbp.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Underlayments
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report James L. Buckner, P.E. @ CBUCK Engineering
Florida License PE-31242
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2024
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL41919_R0_COI_CertOfIndep.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM D19702015
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 02/09/2023
Date Validated 02/24/2023
Date Pending FBC Approval 02/27/2023
Date Approved 04/11/2023
Date Revised 08/09/2023
 
Summary of Products
FL # Model, Number or Name Description
41919.1 “IB-3™ StormStopper Plus” Self-Adhered roofing underlayment comprised of a mineral surface with a rubberized asphalt adhesive and backed with a removable release liner and a selvedge edge.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: Refer to Evaluation Report for Conditions and Limits of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment.
Installation Instructions
 FL41919_R0_II_1_IB3_SSPlus_EVALREPORT.pdf
 Verified By: James L. Buckner, P.E. P.E. #31242
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41919_R0_AE_1_IB3_SSPlus_EVALREPORT.pdf
 Created by Independent Third Party: Yes
 