12856.1 |
0.050" Aluminum Storm Panel |
0.050" Aluminum Storm Panel with Optional Clear Panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Shutter meets requirements for "Wind Zone 4" and Missile Level "D" as defined in ASTM E1996. See installation instructions for specific Design Pressure Ratings by size, additional use limitations and installation instructions. |
Installation Instructions FL12856_R7_II__DWG1.pdf Verified By: Frank L. Bennardo, P.E. PE0046549 Created by Independent Third Party: Yes Evaluation Reports FL12856_R7_AE__EVAL1.pdf Created by Independent Third Party: Yes |
|
12856.2 |
"Safety Edge" Storm Panels |
"Safety Edge" Storm Panels, 28ga (0.018"") Steel, 0.022" Alum (Perf and Non-Perf), Clear Polycarb (Full and Half) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +54/-54 Other: This product is not valid for use within the HVHZ. See Evaluation Report and engineering drawing for additional limitations and conditions of use. |
Installation Instructions FL12856_R7_II__DWG2.pdf Verified By: Frank L. Bennardo, P.E. PE0046549 Created by Independent Third Party: Yes Evaluation Reports FL12856_R7_AE__EVAL2.pdf Created by Independent Third Party: Yes |
|
12856.3 |
24ga Steel Storm Panel |
24ga (0.0232") Steel Storm Panel with Optional Clear Panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +100/-100 Other: This product is not valid for use within the HVHZ or Wind Zone 4. See Evaluation Report and engineering drawing for additional limitations and conditions of use. |
Installation Instructions FL12856_R7_II__DWG3.pdf Verified By: Frank L. Bennardo, P.E. PE0046549 Created by Independent Third Party: Yes Evaluation Reports FL12856_R7_AE__EVAL3.pdf Created by Independent Third Party: Yes |