| 2807.1 |
Mueller Lok (MLK) |
24 Gauge Mueller Lok (MLK) with TripleLok Seam |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +26/-36.4 Other: + 26 / -36.4 psf allowable load at support spacing of 5'-0" o.c. with TripleLok Seams. See Evaluation Report for additional span and load information |
Installation Instructions FL2807_R7_II_MLK Installation Details.pdf Verified By: Brian Campbell 83187 Created by Independent Third Party: No Evaluation Reports FL2807_R7_AE_FL2807.1.pdf Created by Independent Third Party: Yes |
|
|
| 2807.2 |
Mueller Lok (MLK) |
24 Gauge Mueller Lok (MLK) with QuadLok Seam |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +26/-54.6 Other: +26 / -54.6 psf allowable load at support spacing of 5'-0" o.c. with QuadLok Seams. See Evaluation Report for additional gravity and uplift span and load information |
Installation Instructions FL2807_R7_II_MLK Installation Details.pdf Verified By: Brian Campbell 83187 Created by Independent Third Party: No Evaluation Reports FL2807_R7_AE_FL2807.2.pdf Created by Independent Third Party: Yes |
|
|
| 2807.3 |
Mueller Trapeziodal Lok (MTL) |
1. 24 Gauge Mueller-Lok with TripleLok Seam
2. 22 Gauge Mueller-Lok with TripleLok Seam |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +43/-36 Other: + 43 / -36 psf allowable load at support spacing 5'-0" o.c. with Triplelok Seams |
Installation Instructions FL2807_R7_II_MTL Installation Details.pdf Verified By: Brian Campbell 83187 Created by Independent Third Party: Yes Evaluation Reports FL2807_R7_AE_FL2807.3.pdf Created by Independent Third Party: Yes |
|
|
| 2807.4 |
Mueller Trapezoidal Lok (MTL) |
1. 24 Gauge Mueller-Lok with QuadLok Seam
2. 22 Gauge Mueller-Lok with QuadLok Seam |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +43/-45 Other: +43 / -45 psf allowable load for 22 gauge MTL at support spacing 5'-0" o.c. See Evaluation Report for additional gravity and uplift span and load information. |
Installation Instructions FL2807_R7_II_MTL Installation Details.pdf Verified By: Brian Campbell 83187 Created by Independent Third Party: No Evaluation Reports FL2807_R7_AE_FL2807.4.pdf Created by Independent Third Party: Yes |
|
|
| 2807.5 |
PBR |
1. 26 Ga PBR W/ 12-12 Fastener Sp.
2. 26 Ga PBR W/ 5-7-5 Fastener Sp.
3. 24 Ga PBR W/ 12-12 Fastener Sp.
4. 24 Ga PBR W/ 5-7-5 Fastener Sp.
5. 22 Ga PBR W/ 12-12 Fastener Sp.
6. 22 Ga PBR W/ 5-7-5 Fastener Sp. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +31.6/-31.3 Other: +31.6 / -31.3 psf allowable load for 26 gauge with 12-12 fastener spacing at support spacing of 5'-0" o.c. See Evaluation Report for additional pressure and suction and uplift span and load information. |
Installation Instructions FL2807_R7_II_PBR Roof Installation Details.pdf Verified By: Brian Campbell 83187 Created by Independent Third Party: No Evaluation Reports FL2807_R7_AE_FL2807.5.pdf Created by Independent Third Party: Yes |