FL # FL14026-R5
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Central States Manufacturing, Inc.
Address/Phone/Email 302 Jane Place
Lowell, AR 72745
(479) 770-0188
mhowell@centralstatesmfg.com
 
Authorized Signature Michael Howell
mhowell@centralstatesmfg.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Bala Sockalingam, P.E.
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 07/16/2024
Validated By Yoosef Lavi, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL14026_R5_COI_CertificateIndependence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E15922005
TAS 1001995
TAS 1102000
TAS 1252003
UL 18972012
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 09/30/2020
Date Validated 10/01/2020
Date Pending FBC Approval 10/11/2020
Date Approved 12/16/2020
Date Revised 09/02/2023
 
Summary of Products
FL # Model, Number or Name Description
14026.1 Central Snap Maximum 18" wide, 24 ga. Snap lock panel over min 15/32" thick plywood.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-67.5
 Other: Uplift load of 45.0 psf @ clip spacing of 36" o.c. & 67.5 psf @ clip spacing of 24" o.c.
Installation Instructions
 FL14026_R5_II_EvaluationReportC2399_1.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14026_R5_AE_EvaluationReportC2399_1.pdf
 Created by Independent Third Party: Yes
14026.2 Horizon Loc Max 16" wide, min. 26 ga. concealed fastener roof panel over min 15/32" thick plywood or min 7/16" thick OSB deck.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-138.5
 Other: Uplift load of 56 psf at fastener spacing of 6.5" o.c. in 7/16" OSB. Uplift load of 78.5 psf at fastener spacing of 4.75" o.c. with structural sealant in 7/16" OSB. Uplift load of 138.5 psf at fastener spacing of 4.75" o.c. with structural sealant and exterior fasteners at 12" o.c. in 15/32" plywood.
Installation Instructions
 FL14026_R5_II_EvaluationReportC2399_2.pdf
 Verified By: Bala Sockalingam, P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14026_R5_AE_EvaluationReportC2399_2.pdf
 Created by Independent Third Party: Yes
14026.3 Panel-Loc Plus Min 26 ga. panel over min 15/32" thick plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-168.5
 Other: Uplift load of 101 psf at fastener spacing of 24" o.c. and 168.5 psf at fastener spacing of 12" o.c.
Installation Instructions
 FL14026_R5_II_EvaluationReportC2399_3.pdf
 Verified By: Bala Sockalingam 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14026_R5_AE_EvaluationReportC2399_3.pdf
 Created by Independent Third Party: Yes
14026.4 Panel-Loc Plus Min 29 ga. panel over 15/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-168.5
 Other: Uplift load of 101 psf at fastener spacing of 24" o.c. and 168.5 psf at fastener spacing of 12" o.c.
Installation Instructions
 FL14026_R5_II_EvaluationReportC2399_4.pdf
 Verified By: Bala Sockalingam, P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14026_R5_AE_EvaluationReportC2399_4.pdf
 Created by Independent Third Party: Yes
14026.5 Panel-Loc Plus Min 29 ga. panel over 19/32" thick plywood or nom 2" x 4" lathing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5
 Other: Uplift load of 52.5 psf at fastener spacing of 24" o.c.
Installation Instructions
 FL14026_R5_II_EvaluationReportC2399_5.pdf
 Verified By: Bala Sockalingam, P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14026_R5_AE_EvaluationReportC2399_5.pdf
 Created by Independent Third Party: Yes
14026.6 R-Loc Min. 26 ga. panel over min 15/32" thick plywood or min 7/16" thick OSB deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-105.5
 Other: Uplift load of 105.5 psf at fastener spacing of 12" o.c. in 15/32" plywood.
Installation Instructions
 FL14026_R5_II_EvaluationReportC2399_6.pdf
 Verified By: Bala Sockalingam, P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14026_R5_AE_EvaluationReportC2399_6.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe