21450.1 |
Series 1100 |
Series 1100 - 26 Gauge Door Assembly Max Size: 8'-8" x 14'-0" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24.4/-27.0 Other: +24.4/-27.0 psf tested width of 8'-8". PSF values vary to 6'-0" and 8'-8" |
Installation Instructions FL21450_R11_II_T1012_RevF_s.pdf Verified By: John E. Scates PE-51737 Created by Independent Third Party: Yes Evaluation Reports FL21450_R11_AE_EvalRept_Model750_1100_s.pdf Created by Independent Third Party: Yes |
|
21450.2 |
Series 1100 |
Series 1100 - 26 Gauge Door Assembly Max Size: 12'-0" x 14'-0" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +19.4/-22.7 Other: +19.4/-22.7 psf tested width of 10'-0". PSF values vary to 10'-0" and 12'-0". |
Installation Instructions FL21450_R11_II_T1013_RevF_s.pdf Verified By: John E. Scates PE-51737 Created by Independent Third Party: Yes Evaluation Reports FL21450_R11_AE_EvalRept_Model750_1100_s.pdf Created by Independent Third Party: Yes |
|
21450.3 |
Series 1850/3100 |
Series 1850/3100 - 26 Gauge Door Assembly Max Size: 20'-0" x 20'-0" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +42.5/-45 Other: +42.5/-45.0 psf tested width of 16'-0". For non-impact rated doors, psf values vary to 8'-0" and 20'-0" widths |
Installation Instructions FL21450_R11_II_T1017_RevB_sFL.pdf Verified By: John E. Scates P.E. FL 51737 Created by Independent Third Party: Yes Evaluation Reports FL21450_R11_AE_EvalRept_Model850_1850_3100_s.pdf Created by Independent Third Party: Yes |
|
21450.4 |
Series 1850/3100-IM |
Series 1850/3100-IM - Impact Resistant 26 Gauge Door Assembly Max Size: 16'-0" x 20'-0" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +42.5/-45 Other: PSF values vary by width. 14'-0" width: +40.0/-40.0 and 16'-0" width: +42.5/-45.0 |
Installation Instructions FL21450_R11_II_T1017_RevB_sFL.pdf Verified By: John E. Scates P.E. FL 51737 Created by Independent Third Party: Yes Evaluation Reports FL21450_R11_AE_EvalRept_Model850_1850_3100_s.pdf Created by Independent Third Party: Yes |
|
21450.5 |
Series 3400 |
Series 3400 - 24 Gauge Door Assembly Max Size: 12'-0" X 20'-0" (HVHZ) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +43.0/-49.0 Other: FOR USE IN HIGH VELOCITY HURRICANE ZONES |
Installation Instructions FL21450_R11_II_T1011-RevC_sFL.pdf Verified By: John E. Scates P.E. FL 51737 Created by Independent Third Party: Yes Evaluation Reports FL21450_R11_AE_EvalRept_Model850_1850_3100_s.pdf Created by Independent Third Party: Yes |
|
21450.6 |
Series 3652 |
Series 3652 - 26 Gauge Door Assembly - Max Size: 18'-0" x 20'-0" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +36/-40 Other: Design pressure listed is at test width of 12'-0". For pressures versus widths, see table, on page 1, of drawing T1014. Not for use in High Velocity Hurricane Zones. |
Installation Instructions FL21450_R11_II_T1014_RevC_s.pdf Verified By: John E. Scates P.E. FL 51737 Created by Independent Third Party: Yes Evaluation Reports FL21450_R11_AE_EvalRept_Model3652_s.pdf Created by Independent Third Party: Yes |
|
21450.7 |
Series 690 |
Series 690 - 26 Gauge Door Assembly Max Size: 10'-0"X12'-0" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +28.2/-32.9 Other: Pressure varies by width from +64.2/-75.0 at 4' wide to +28.2/-32.9 at 10' wide. See drawings. |
Installation Instructions FL21450_R11_II_T2000_Rev-_s.pdf Verified By: John E. Scates P.E. FL 51737 Created by Independent Third Party: Yes Evaluation Reports FL21450_R11_AE_EvalRept_Model690_s.pdf Created by Independent Third Party: Yes |
|
21450.8 |
Series 750 |
Series 750 - 26 Gauge Door Assembly Max Size: 3'-0" x 12'-0" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-45 Other: Not for use in High Velocity Hurricane Zones |
Installation Instructions FL21450_R11_II_T1000_RevG_s.pdf Verified By: John E. Scates, P.E. 51737 Created by Independent Third Party: Yes Evaluation Reports FL21450_R11_AE_EvalRept_Model750_1100_s.pdf Created by Independent Third Party: Yes |
|
21450.9 |
Series 750 |
Series 750 - 26 Gauge Door Assembly Max Size: 6'-0" x 12'-0" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +19.9/-24.4 Other: Design Pressures listed as a test width of 6'-0". For pressures vs. widths, see table, sheet 1 of 2, dwg T1001. Not for use in High Velocity Hurricane Zones. |
Installation Instructions FL21450_R11_II_T1001_RevG_s.pdf Verified By: John E. Scates, P.E. 51737 Created by Independent Third Party: Yes Evaluation Reports FL21450_R11_AE_EvalRept_Model750_1100_s.pdf Created by Independent Third Party: Yes |
|
21450.10 |
Series 750 |
Series 750 - 26 Gauge Door Assembly Max Size: 8'-8" x 12'-0" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24.4/-27.0 Other: +24.4/-27.0 psf tested width of 8'-8". PSF values vary to 6'-0" and 8'-8". |
Installation Instructions FL21450_R11_II_T1002_RevH_s.pdf Verified By: John E. Scates, P.E. 51737 Created by Independent Third Party: Yes Evaluation Reports FL21450_R11_AE_EvalRept_Model750_1100_s.pdf Created by Independent Third Party: Yes |
|
21450.11 |
Series 750 |
Series 750 - 26 Gauge Door Assembly Max Size: 10'-0" x 12'-0" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +19.4/-22.7 Other: Not for use in High Velocity Hurricane Zones. |
Installation Instructions FL21450_R11_II_T1003_RevH_s.pdf Verified By: John E. Scates, P.E. 51737 Created by Independent Third Party: Yes Evaluation Reports FL21450_R11_AE_EvalRept_Model750_1100_s.pdf Created by Independent Third Party: Yes |
|
21450.12 |
Series 850 |
Series 850 - 24 Gauge Door Assembly Max Size: 8'-8" X 12'-0" (HVHZ) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +46.0/-54.0 Other: FOR USE IN HIGH VELOCITY HURRICANE ZONES |
Installation Instructions FL21450_R11_II_T1006-RevG_sFL.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL21450_R11_AE_EvalRept_Model850_1850_3100_s.pdf Created by Independent Third Party: Yes |
|
21450.13 |
Series 850S |
Series 850S - 26 Gauge Gauge Door Assembly Max Size: 12'-0"X12'-0" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +46.0/-54.0 Other: +46.0/-54.0 psf tested width of 8'-8". For non-impact rated doors, psf values vary to 6'-0" and 12'-0" widths |
Installation Instructions FL21450_R11_II_T1006-S-RevG_sFL.pdf Verified By: John E. Scates FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL21450_R11_AE_EvalRept_Model850_1850_3100_s.pdf Created by Independent Third Party: Yes |
|
21450.14 |
Series 850S-IM |
Series 850S_Impact Rated. 26 Gauge Door Assembly Max Size: 8'-8" X 12'-0" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +46.0/-54.0 Other: |