21873.1 |
6/0 x 8/0 Tiffany Ashville Double ARCH top w/TDL |
6/0 x 8/0 Tiffany Ashville Double ARCH top w/TDL |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Product not tested for water penetration resistance. Therefore, the product must be used where water penetration is not required or where an overhang meeting the Requirements of the Current Edition of the FBC/FRC has been employed. |
Installation Instructions FL21873_R2_II_DSA0005_RevA_Asheville-Double-ArchTop-TDL_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL21873_R2_AE_PERNo2483_Rev1_ss.pdf Created by Independent Third Party: Yes |
|
21873.2 |
7/0 x 8/0 Double Full Lite/2 Panels |
7/0 x 8/0 Double Full Lite/2 Panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Product not tested for water penetration resistance. Therefore, the product must be used where water penetration is not required or where an overhang meeting the Requirements of the Current Edition of the FBC/FRC has been employed. |
Installation Instructions FL21873_R2_II_DSA0003_RevA_ImpactDouble7080_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL21873_R2_AE_PERNo2483_Rev1_ss.pdf Created by Independent Third Party: Yes |
|
21873.3 |
Alexandria 9 Lite Single Door with Sidelites and Transom |
Alexandria 9 Lite Single Door with Sidelites and Transom |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Product not tested for water penetration resistance. Therefore, the product must be used where water penetration is not required or where an overhang meeting the Requirements of the Current Edition of the FBC/FRC has been employed. |
Installation Instructions FL21873_R2_II_DSA0002_RevA_Alexandria-9Lite-Sidelites-Transom_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL21873_R2_AE_PERNo2483_Rev1_ss.pdf Created by Independent Third Party: Yes |
|
21873.4 |
Complete Collection, Single and Double Doors |
Complete Collection, Single and Double Doors, Inswing |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: See Performance Rating table on Sheet 1 of the Installation Instructions regarding Water Penetration Rating and Limitations. |
Installation Instructions FL21873_R2_II_DSA0006_Rev0_Complete Collection - X and XX Doors - Inswing_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL21873_R2_AE_PERNo2691_Rev0_ss.pdf Created by Independent Third Party: Yes |
|
21873.5 |
Complete Collection, Single and Double Doors |
Complete Collection, Single and Double Doors, Outswing |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: See Performance Rating table on Sheet 1 of the Installation Instructions regarding Water Penetration Rating and Limitations. |
Installation Instructions FL21873_R2_II_DSA0007_Rev0_Complete Collection - X and XX Doors - Outswing_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL21873_R2_AE_PERNo2691_Rev0_ss.pdf Created by Independent Third Party: Yes |
|
21873.6 |
Double Full View Door with Full View Transom |
Double Full View Door with Full View Transom |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Product not tested for water penetration resistance. Therefore, the product must be used where water penetration is not required or where an overhang meeting the Requirements of the Current Edition of the FBC/FRC has been employed. |
Installation Instructions FL21873_R2_II_DSA0001_RevA_ImpactDouble6010DoorXX_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL21873_R2_AE_PERNo2483_Rev1_ss.pdf Created by Independent Third Party: Yes |
|
21873.7 |
Full View Door with Full View Sidelites and Transom |
Full View Door with Full View Sidelites and Transom |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Product not tested for water penetration resistance. Therefore, the product must be used where water penetration is not required or where an overhang meeting the Requirements of the Current Edition of the FBC/FRC has been employed. |
Installation Instructions FL21873_R2_II_DSA0004_RevA_ImpactSingleFullLite-Sidelites-Transom_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL21873_R2_AE_PERNo2483_Rev1_ss.pdf Created by Independent Third Party: Yes |