|
22363.1 |
Fiberglass Side-Hinged Door Unit |
6'-8" Opaque I/S Single Door |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-65 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do exceed the design pressures listed. 3'-0" x 6'-8" max nominal size. Hurricane protective system required in HVHZ, but not in the Wind Borne Debris Region. See DWG-MA-WL0187 for details. |
Certification Agency Certificate FL22363_R2_C_CAC_NI013717.17-R1.pdf Quality Assurance Contract Expiration Date 05/31/2021 Installation Instructions FL22363_R2_II__FL0187.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22363_R2_AE_514010A.pdf FL22363_R2_AE_514014A.pdf Created by Independent Third Party: Yes |
|
22363.2 |
Fiberglass Side-Hinged Door Unit |
6'-8" Opaque O/S Single Door |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do exceed the design pressures listed. 3'-0" x 6'-8" max nominal size. Hurricane protective system required in HVHZ, but not in the Wind Borne Debris Region. See DWG-MA-WL0187 for details. |
Certification Agency Certificate FL22363_R2_C_CAC_NI013717.17-R1.pdf Quality Assurance Contract Expiration Date 05/31/2021 Installation Instructions FL22363_R2_II__FL0187.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22363_R2_AE_514010A.pdf FL22363_R2_AE_514014A.pdf Created by Independent Third Party: Yes |
|
22363.3 |
Fiberglass Side-Hinged Door Unit |
6'-8" Opaque I/S or O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system required in HVHZ, but not in the Wind Borne Debris Region. See DWG-MA-WL0187 for details. |
Certification Agency Certificate FL22363_R2_C_CAC_NI013717.17-R1.pdf Quality Assurance Contract Expiration Date 05/31/2021 Installation Instructions FL22363_R2_II__FL0187.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22363_R2_AE_514008A.pdf FL22363_R2_AE_514012A.pdf Created by Independent Third Party: Yes |
|
22363.4 |
Fiberglass Side-Hinged Door Unit |
6'-8" Glazed I/S or O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system required in HVHZ and the Wind Borne Debris Region. See DWG-MA-WL0189 for details. |
Certification Agency Certificate FL22363_R2_C_CAC_NI013717.03-R1.pdf Quality Assurance Contract Expiration Date 05/31/2021 Installation Instructions FL22363_R2_II__FL0189.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22363_R2_AE_514008A.pdf FL22363_R2_AE_514012A.pdf Created by Independent Third Party: Yes |
|
22363.5 |
Fiberglass Side-Hinged Door Unit |
6'-8" 3/4-Lite Glazed I/S or O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system required in HVHZ and the Wind Borne Debris Region. See DWG-MA-WL0193 for details. |
Certification Agency Certificate FL22363_R2_C_CAC_NI013717.04-R1.pdf Quality Assurance Contract Expiration Date 05/31/2021 Installation Instructions FL22363_R2_II__FL0193.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22363_R2_AE_514008A.pdf FL22363_R2_AE_514012A.pdf Created by Independent Third Party: Yes |
|
22363.6 |
Fiberglass Side-Hinged Door Unit |
6'-8" Impact Glazed I/S or O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Evaluated for use in locations adhering to the Florida Building Code, excluding the High Velocity Hurricane Zone, and where pressure requirements do exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system not required in the Wind Borne Debris Region. See DWG-MA-WL0195 for details. |
Certification Agency Certificate FL22363_R2_C_CAC_NI013717.05-R1.pdf Quality Assurance Contract Expiration Date 05/31/2021 Installation Instructions FL22363_R2_II__FL0195.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22363_R2_AE_514008A.pdf FL22363_R2_AE_514012A.pdf Created by Independent Third Party: Yes |
|
22363.7 |
Fiberglass Side-Hinged Door Unit |
8'-0" Opaque I/S Single Door |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-65 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do exceed the design pressures listed. 3'-0" x 8'-0" max nominal size. Hurricane protective system required in HVHZ, but not in the Wind Borne Debris Region. See DWG-MA-WL0188 for details. |
Certification Agency Certificate FL22363_R2_C_CAC_NI013717.18-R1.pdf Quality Assurance Contract Expiration Date 05/31/2021 Installation Instructions FL22363_R2_II__FL0188.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22363_R2_AE_514009A.pdf FL22363_R2_AE_514013A.pdf Created by Independent Third Party: Yes |
|
22363.8 |
Fiberglass Side-Hinged Door Unit |
8'-0" Opaque O/S Single Door |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do exceed the design pressures listed. 3'-0" x 8'-0" max nominal size. Hurricane protective system required in HVHZ, but not in the Wind Borne Debris Region. See DWG-MA-WL0188 for details. |
Certification Agency Certificate FL22363_R2_C_CAC_NI013717.18-R1.pdf Quality Assurance Contract Expiration Date 05/31/2021 Installation Instructions FL22363_R2_II__FL0188.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22363_R2_AE_514009A.pdf FL22363_R2_AE_514013A.pdf Created by Independent Third Party: Yes |
|
22363.9 |
Fiberglass Side-Hinged Door Unit |
8'-0" Opaque I/S or O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system required in HVHZ, but not in the Wind Borne Debris Region. See DWG-MA-WL0188 for details. |
Certification Agency Certificate FL22363_R2_C_CAC_NI013717.18-R1.pdf Quality Assurance Contract Expiration Date 05/31/2021 Installation Instructions FL22363_R2_II__FL0188.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22363_R2_AE_514007A.pdf FL22363_R2_AE_514011A.pdf Created by Independent Third Party: Yes |
|
22363.10 |
Fiberglass Side-Hinged Door Unit |
8'-0" Glazed I/S or O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system required in HVHZ and the Wind Borne Debris Region. See DWG-MA-WL0190 for details. |
Certification Agency Certificate FL22363_R2_C_CAC_NI013717.08-R1.pdf Quality Assurance Contract Expiration Date 05/31/2021 Installation Instructions FL22363_R2_II__FL0190.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22363_R2_AE_514007A.pdf FL22363_R2_AE_514011A.pdf Created by Independent Third Party: Yes |
|
22363.11 |
Fiberglass Side-Hinged Door Unit |
8'-0" Impact Glazed I/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +40/-45 Other: Evaluated for use in locations adhering to the Florida Building Code, excluding the High Velocity Hurricane Zone, and where pressure requirements do exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system not required in the Wind Borne Debris Region. See DWG-MA-WL0196 for details. |
Certification Agency Certificate FL22363_R2_C_CAC_NI013717.09-R1.pdf Quality Assurance Contract Expiration Date 05/31/2021 Installation Instructions FL22363_R2_II__FL0196.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22363_R2_AE_514007A.pdf FL22363_R2_AE_514011A.pdf Created by Independent Third Party: Yes |
|
22363.12 |
Fiberglass Side-Hinged Door Unit |
8'-0" Impact Glazed O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +45/-40 Other: Evaluated for use in locations adhering to the Florida Building Code, excluding the High Velocity Hurricane Zone, and where pressure requirements do exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system not required in the Wind Borne Debris Region. See DWG-MA-WL0196 for details. |
Certification Agency Certificate FL22363_R2_C_CAC_NI013717.09-R1.pdf Quality Assurance Contract Expiration Date 05/31/2021 Installation Instructions FL22363_R2_II__FL0196.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22363_R2_AE_514007A.pdf FL22363_R2_AE_514011A.pdf Created by Independent Third Party: Yes |
|
22363.13 |
HPC Fiberglass Side-Hinged Door Unit |
8'-0" Glazed I/S or O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +47/-47 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system required in HVHZ and in the Wind Borne Debris Region. Door top rails stamped "HPC". See DWG-MA-WL0192 for details. |
Certification Agency Certificate FL22363_R2_C_CAC_NI013717.07-R1.pdf Quality Assurance Contract Expiration Date 05/31/2021 Installation Instructions FL22363_R2_II__FL0192.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22363_R2_AE_514007A.pdf FL22363_R2_AE_514011A.pdf Created by Independent Third Party: Yes |
|
22363.14 |
HPC Fiberglass Side-Hinged Door Unit |
6'-8" Glazed I/S or O/S Single or Double Door w/ or w/o Sidelites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system required in HVHZ and the Wind Borne Debris Region. Door top rails stamped "HPC". See DWG-MA-WL0191 for details. |
Certification Agency Certificate FL22363_R2_C_CAC_NI013717.02-R1.pdf Quality Assurance Contract Expiration Date 05/31/2021 Installation Instructions FL22363_R2_II__FL0191.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22363_R2_AE_514008A.pdf FL22363_R2_AE_514012A.pdf Created by Independent Third Party: Yes |